INSTALLATION |
Continued |
For propane/LP gas, the installer must supply an |
external regulator. The external regulator will |
reduce incoming gas pressure. You must reduce |
incoming gas pressure to between 11 and 14 inches |
of water. If you do not reduce incoming gas pres- |
sure, heater regulator damage could occur. Install |
the external regulator with the vent pointing down |
as shown in Figure 15. Pointing the vent down |
protects it from freezing rain or sleet. |
CAUTION: Use only new, |
black iron or steel pipe. Inter- |
be used in certain areas. Check |
Install sediment trap in supply line as shown in Figure 16. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
IMPORTANT: Hold the pressure regulator with wrench when connecting it to gas piping and/or fittings. Do not over tighten pipe connection to regulator. The regulator body could be damaged.
Pressure | Heater |
Regulator | |
| Cabinet |
your local codes. Use pipe of |
large enough diameter to allow |
proper gas volume to heater. If |
pipe is too small, undue loss of |
volume will occur. |
Typical Inlet Pipe Diameter - 3/8" (9.5 mm) or |
greater |
Installation must include equipment shutoff valve, |
union and plugged 1/8" NPT tap. Locate NPT tap |
within reach for test gauge hook up. NPT tap must |
be upstream from heater (see Figure 16). |
IMPORTANT: Install an equipment shutoff valve |
in an accessible location. The equipment shutoff |
valve is for turning on or shutting off the gas to |
the appliance. |
Apply pipe joint sealant lightly to male NPT |
threads. This will prevent excess sealant from |
going into pipe. Excess sealant in pipe could result |
Test Gauge Connection*
3/8" NPT Pipe Nipple
Tee Joint
Reducer Bushing to 1/8" NPT
1/8" NPT
Plug Tap
Trap | Tee | Joint | |
Pipe | |||
Sediment | |||
Nipple | |||
| |||
| Cap |
|
Equipment
Shutoff
Valve *
3"
(7.6 cm)
Min. Natural Gas From Gas Meter (4" W.C. to 10.5" W.C. Pressure)
Propane/LP From External Regulator (11" W.C. to 14" W.C. Pressure)
in clogged heater valves. |
|
WARNING: Use pipe joint | |
sealant that is resistant to liquid | |
petroleum (LP) gas. |
|
Propane/LP | External |
Supply Tank | |
| Regulator |
| Vent |
| Pointing |
| Down |
Figure 15 - External Regulator With Vent | |
Pointing Down |
|
Figure 16 - Gas Connection
*A CSA
CHECKING GAS CONNECTIONS
WARNING: Test all gas piping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once.