SAFETY INFORMATION

Continued

5.This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, page 5.

6.Keep all air openings in front and bottom of heater clear and free of debris. This will insure enough air for proper combustion.

7.If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced.

8.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

9.Before using furniture polish, wax, carpet cleaner or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.

10.Do not use heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

11.Turn off and let cool before servicing. Only a qualified service person should service and repair heater.

12.Operating heater above elevations of 4,500 feet (1,371 m) could cause pilot outage.

13.To prevent performance problems, do not use propane/LPfuel tank of less than 100 lbs. (45 kg) capacity.

14.Provide adequate clearances around air openings.

LOCAL CODES

Install and use heater with care. Follow all lo- cal codes. In the absence of local codes, use the latest edition of National Fuel Gas Code, ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

PRODUCT

IDENTIFICATION

Heater Cabinet

Control Knob (under door)

Glass Panel

Ignitor

Figure 1 - Vent-Free Gas Heater

UNPACKING

1.Remove heater from carton.

2.Remove all protective packaging applied to heater for shipment.

3.Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.

PRODUCT FEATURES

SAFETY DEVICE

This heater has a pilot with an Oxygen Deple- tion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

IGNITION SYSTEM

This heater has either a piezo ignitor or electronic ignitor to light heater fuel supply.

THERMOSTATIC HEAT CONTROL

Thermostat models have a thermostat sensing bulb and a control valve. This results in the great- est heater comfort. This can also result in lower gas bills.

4

www.desatech.com

116292-01D

Image 4
Contents What to do if YOU Smell GAS Table of Contents Safety Information Product Features Local CodesProduct Identification UnpackingAIR for Combustion Ventilation Providing Adequate VentilationFollowing are excerpts from National Fuel Unusually Tight ConstructionDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceInstallation Ventilation AIRCheck GAS Type Ventilation Air From Inside BuildingInstallation Items Installing IgnitorInstalling Glass Panel Removing Front Panel of HeaterLocating Heater This heater is designed to be mounted on a wallInstalling Heater to Wall Installing Bottom Mounting Screws Connecting to GAS SupplyPlacing Heater On Mounting Bracket Checking GAS Connections Test Pressures In Excess Of 1/2 Psig 3.5 kPa Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaConnecting to Electrical Supply For Your Safety Read Before LightingOperating Heater Extension CordLighting Instructions To Turn OFF GAS To ApplianceThermostat Control Operation Shutting Off HeaterManual Lighting Procedure Inspecting HeaterBurner Flame Pattern Pilot Flame PatternCleaning Maintenance ODS/PILOT and BurnerBurner Pilot AIR Inlet CabinetTroubleshooting Observed Problem Possible Cause RemedyGoes out when control knob is Control knob not pressed Delayed ignition of burner Manifold pressure is too lowBurner orifice is clogged Clean burner see Cleaning ODS/pilot lights but flameWalls or furniture Cleaners, etc. may turn into No power to electric outlet 60Hz outletSlight smoke or odor during Air passageways on heaterMent above Specifications Wiring DiagramsFor purposes of input adjustment LSL18NT, SL18NT and VSL18NT LSL18PT, SL18PT and VSL18PTAccessories Technical ServiceReplacement Parts Service Publications Service HintsIllustrated Parts Breakdown Models LSL18NT, LSL18PT, SL18NT, SL18PT, VSL18NT and VSL18PTParts List Parts Centrals 116292-01D Warranty Information Keep this WarrantyQUÉ Hacer SI Percibe Olor a GAS Tabla DE Contenido Información DE Seguridad Información DE Códigos LocalesDesempaque Características DEL ProductoAire Para Combustión Ventilación Cómo Proveer LA Ventilación AdecuadaConstrucción inusualmente sellada Espacio confinado y no confinadoAire Para Ventilación Aire del interior de la construcción para ventilaciónVerifique EL Tipo DE GAS InstalaciónAire del exterior para ventilación Artículos DE Instalación Desmontaje DEL Panel Anterior DEL CalentadorInstalación DEL Encendedor Instalación del panel de vidrioCorrientes de aire fuertes Ubicación DEL CalentadorSoporte de montaje Instalación DEL Calentador EN LA ParedDoble el anclaje de pared como se muestra en la figura Conexión AL Suministro DE GAS Colocación del calentador en el soporte de montajeInstalación de los tornillos de montaje InferioresPermita el paso del volumen de gas Revisión DE LAS Conexiones DE GASLo suficientemente grande para que Adecuado al calentador. Si la tuberíaCierre del equipo Regule la presión del sistema de tubería deUsando aire comprimido Repare todas las fugas inmediatamenteFuncionamiento DEL Calentador Conexión a LA Alimentación EléctricaCable DE Extensión Para SU SEGURIDAD, LEA Esto Antes DE EncenderloInstrucciones DE Encendido Funcionamiento DELApague el piloto Funcionamiento DEL Patrón DE LA Llama DELCalentador Procedimiento DELimpieza Y Mantenimiento Piloto CON ODS Y QuemadorEntrada DE Aire AL Piloto DEL Quemador GabineteSolución DE Problemas Problema Observado Causa Posible RemedioLa posición del regulador de gas no es la correcta Reemplace el regulador de gasCausa Posible Remedio El problema desaparecerá Hay aire en la línea de gas Hasta que se elimine el aireLínea de gas Los conductos de aire en elCia anterior Diagramas DE Cableado EspecificacionesLSL18NT, SL18NT y VSL18NT LSL18PT, SL18PT y VSL18PTAccesorios Servicio TécnicoPublicaciones DE Servicio Piezas DE RepuestoClasificación Ilustrada DE Piezas Modelos LSL18NT, LSL18PT, SL18NT, SL18PT, VSL18NT Y VSL18PTLista DE Piezas Laporte’s Parts & Service 2444 N th Street Centrales DE PiezasNotas Información DE Garantía Guarde Esta Garantía