Coleman 5075 Series, 5070 Series manual Propane GAS, Fire/Explosion, Additional Safety Information

Page 3

MAKE SURE ADEQUATE VENTILATION IS PROVIDED. Provide a fresh

GENERAL

outside air opening at least three (3) square feet (0.3 m2) or its equivalent, i.e., 1' x 3' (0.3 m

SAFETY

x 0.9 m) for each heating unit. DO NOT USE THIS HEATER IN LIVING QUARTERS

INFORMATION

OR WHILE SLEEPING! California lists carbon monoxide as a reproductive toxin under

Continued

Proposition 65.

 

PROPANE GAS:

 

This product is fueled by propane gas. Propane gas is invisible, odorless, and

 

flammable. An odorant is normally added to help detect leaks and can be described as a

 

“rotten egg” smell. The odorant can fade over time so leaking gas is not always detectable

 

by smell alone.

 

Propane gas is heavier than air and leaking propane will sink to the lowest level

 

possible. It can be ignited by ignition sources including matches, lighters, sparks or open

 

flames of any kind many feet away from the original leak. Use only propane gas set up for

 

vapor withdrawal.

 

Propane gas should be stored and used in compliance with local ordinances and

 

codes or with ANSI/NFPA 58. Turn off propane when not in use.

 

FIRE/EXPLOSION:

During operation, this product can be a source of ignition. Keep heater area clear and free from combustible materials, gasoline, paint thinner, cleaning solvents and other flammable vapors and liquids. Do not use heater in areas with high dust content.

MINIMUM HEATER CLEARANCES FROM COMBUSTIBLE MATERIALS: TWO

(2)FEET (0.6 M) FROM SIDES AND REAR, FOUR (4) FEET (1.2 M) FROM TOP, AND SIX (6) FEET (1.8) FROM THE OUTLET. Keep heater at least six (6) feet (1.8 m) away from propane tanks and keep propane hoses away from outlet opening of the heater.

ADDITIONAL SAFETY INFORMATION:

Never alter or modify heater, propane hose/regulator assembly or propane cylinders. Do not attach duct work of any kind to this heater.

Always inspect heater, propane hoses and propane cylinders before use. Do not use if leaking propane or if damaged. Replace hoses that have excessive wear, abrasion or cuts. Use only Coleman repair parts and Coleman propane hoses and regulator assemblies.

KEEP OUT OF REACH OF CHILDREN.

Heater will remain hot up to thirty (30) minutes after being turned off.

Operate heater only on level, stable surface.

Use only the electrical voltage and frequency specified on product decal.

Electrical grounding instructions — this heater is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.

Use only a three-prong, grounded extension cord.

Make sure heater is plugged into outlet before igniting heater.

Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

Do not block or obstruct the flow of combustion and ventilation air.

Blower (forced air) and radiant type heaters must not be directed toward any propane-gas container within 20 feet (6 m).

ENGLISH

3

Image 3
Contents Propane FORCED-AIR Heaters General Safety InformationCarbon Monoxide Poisoning Minimum Heater Clearances from Combustible Materials TWO Additional Safety InformationPropane GAS FIRE/EXPLOSIONSection Contents ProductPropane Supply UnpackingVentilation Warning PreparationNumber of Tanks Required Operation To Start HeaterExtension Cord Size Requirement OperationMaintenance To Stop HeaterStorage Electrode MaintenanceSymptom Possible Cause RemedyHOW Often HOW to Service ProceduresReplacing Motor Replacing Electrode Service ProceduresSpecifications Replacing FANWiring Diagram Replacement PartsChaufferettes AIR PULSÉ, AU GAZ Propane Oxycarbonisme Généralités SécuritéGardez LA Chaufferette Hors DE LA Portée DES Enfants GAZ PropaneIncendie OU Explosion Autres Renseignements DE SécuritéModèle de 40 000 btu/h Identifica Tion ProduitCoupe transversale du fonctionnement modèle 5070A illustré Alimentation EN PropaneNombre DE Bonbonnes Requises Ventilation AvertissementMise en marche de la chaufferette PréparationFonction Nement Exigences quant au cordon de rallonge Arrêt de la chaufferette RangementEntretien Électrode Pièce Quand Comment Indice Cause Possible SolutionMéthodes DE Dépannage Remplacement DU MoteurRemplacement DE L’HÉLICE Remplacement DE L’ÉLECTRODEDonnées Techniques Modèle 5070A Schéma DE CâblageCalefactor a GAS Propano CON Ventilación Forzada Advertencia Información General Sobre Seguri DADGeneral Sobre SeguridadInformación Página Contenido SecciónSpanish Preparación VentilaciónPara encender el calefactor OperaciónContinuación Modelo 5070A OperaciónMantenimiento Para apagar el calefactorElectrodo Solución AdvertenciaSíntoma Causa ProbableCómo Reemplazar EL Motor DE ServicioCómo Reemplazar EL Electrodo Cómo Reemplazar EL VentiladorModelo 5070A Diagrama DE ConexionesWarranty Garantie Garantía Canada L5R Technical ServiceClientèle Servicio Técnico Assistance

5070 Series, 5075 Series specifications

Coleman, a well-known brand in outdoor recreation equipment, offers a variety of innovative tents designed to enhance camping experiences. Among its popular lines are the Coleman 5075 Series and the Coleman 5070 Series, both featuring unique attributes that cater to diverse outdoor needs.

The Coleman 5075 Series is recognized for its robust construction and weather-resistant features. One of its standout qualities is the WeatherTec system, which includes patented welded floors and inverted seams that help keep water out, ensuring a dry and comfortable camping environment even during heavy rainfall. The tent is designed with extended window awnings that provide additional protection from leaks, while also promoting ventilation to minimize condensation inside.

The 5075 Series tents are spacious, accommodating multiple campers with ease, thanks to their generous dimensions. Designed for quick and hassle-free setup, these models employ the Insta-Clip pole system, allowing for swift assembly in only a few minutes. Additionally, they incorporate a gear storage system that keeps personal items organized and within reach, enhancing the overall convenience for users.

On the other hand, the Coleman 5070 Series focuses on versatility and ease of use. One of its hallmarks is the Easy Set-Up feature, which allows campers to pitch the tent quickly without complex assembly procedures. This makes the 5070 Series particularly appealing to families and novice campers looking to maximize their outdoor time without the hassle of lengthy setups.

Technology plays a significant role in both series, particularly with the inclusion of Coleman’s unique UVGuard material, which provides enhanced protection against harmful UV rays, ensuring that campers are shielded during sunny outings. The tents are also equipped with spacious vestibules, which provide additional storage space for gear and added protection from the elements.

In terms of durability, both series maintain a sturdy design with high-quality materials engineered to withstand the rigors of outdoor use. The Coleman 5075 and 5070 Series tents are built to endure various weather conditions, making them ideal options for both weekend getaways and extended camping trips.

In summary, the Coleman 5075 and 5070 Series tents epitomize the brand's commitment to quality, convenience, and protection in outdoor camping. With thoughtful designs that incorporate weather-resistant technologies and user-friendly features, these tents provide campers with reliable shelter to enhance their outdoor adventures.