3.Connect POL fitting on hose/regulator assembly to propane tank(s). Turn POL fitting counterclockwise into threads on tank. Tighten firmly. IMPORTANT: Tighten regulator with vent pointing down. Pointing vent down protects regulator from weather damage.

PREPARATION

Continued

ENGLISH

Regulator With Vent Pointing Down

4.Open valve on propane tank(s) slowly. Note: If not opened slowly, excess-flow check valve on propane tank will stop gas flow. If this happens, close propane valve and open again slowly.

5.Check all connections for leaks. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak that must be corrected before using heater.

6.Close propane supply valve.

WARNING

Review and understand the warnings in the General Safety Information Section. They are needed to safely operate this heater. Follow all local ordi- nances or codes when using this heater.

To Start Heater

1.Follow all preparation, ventilation, and safety information.

2.Locate heater on stable and level surface. Make sure strong drafts do not blow into front or rear of heater. Do not use in areas directly exposed to water spray, rain, and/or dripping water.

3.Open valve on propane tank(s) slowly. Note: If not opened slowly, excess-flow check valve on propane tank will stop gas flow. If this happens, close propane valve and open again slowly.

OPERATION

Continued

7

Image 7
Contents Propane FORCED-AIR Heaters Information General SafetyCarbon Monoxide Poisoning Minimum Heater Clearances from Combustible Materials TWO Additional Safety InformationPropane GAS FIRE/EXPLOSION Section Contents ProductPropane Supply UnpackingPreparation Ventilation WarningNumber of Tanks Required Operation To Start HeaterExtension Cord Size Requirement OperationTo Stop Heater MaintenanceStorage Electrode MaintenanceRemedy Symptom Possible CauseHOW Often HOW to Procedures ServiceReplacing Motor Replacing Electrode Service ProceduresSpecifications Replacing FANWiring Diagram Replacement PartsChaufferettes AIR PULSÉ, AU GAZ Propane Oxycarbonisme Généralités SécuritéGardez LA Chaufferette Hors DE LA Portée DES Enfants GAZ PropaneIncendie OU Explosion Autres Renseignements DE SécuritéModèle de 40 000 btu/h Identifica Tion ProduitCoupe transversale du fonctionnement modèle 5070A illustré Alimentation EN PropaneNombre DE Bonbonnes Requises Ventilation AvertissementPréparation Mise en marche de la chaufferetteFonction Nement Exigences quant au cordon de rallonge Rangement Arrêt de la chaufferetteEntretien Électrode Pièce Quand Comment Indice Cause Possible SolutionMéthodes DE Dépannage Remplacement DU MoteurRemplacement DE L’ÉLECTRODE Remplacement DE L’HÉLICEDonnées Techniques Modèle 5070A Schéma DE CâblageCalefactor a GAS Propano CON Ventilación Forzada Advertencia Información General Sobre Seguri DADSeguridad General SobreInformación Página Contenido SecciónSpanish Preparación VentilaciónOperación Para encender el calefactorContinuación Modelo 5070A OperaciónMantenimiento Para apagar el calefactorElectrodo Solución AdvertenciaSíntoma Causa ProbableCómo Reemplazar EL Motor DE ServicioCómo Reemplazar EL Electrodo Cómo Reemplazar EL VentiladorModelo 5070A Diagrama DE ConexionesWarranty Garantie Garantía Canada L5R Technical ServiceClientèle Servicio Técnico Assistance