Coleman 5075 Series, 5070 Series manual Symptom Possible Cause, Remedy, HOW Often HOW to

Page 11

WARNING

TROUBLE-

Never attempt to service heater while it is plugged in, connected to propane

SHOOTING

 

supply, operating or hot. Severe burns and electrical shock can occur.

 

SYMPTOM

POSSIBLE CAUSE

Fan does not turn

No electrical power to heater

when heater is

 

plugged in.

 

 

Fan blades bent

 

Defective motor

Heater will not

User did not follow prepara-

ignite.

tion or operation instruc-

 

tions properly

 

No spark at electrode. To test

 

for spark, follow step 9 un-

 

der Replacing Electrode,

 

page 13. If you see spark at

 

ignitor, have heater serviced

 

by qualified service person.

 

If no spark seen:

 

A) Loose or disconnected

 

ignitor wire

 

B) Wrong spark gap

 

C) Piezo ignitor loose

 

D) Bad electrode

 

E) Bad piezo ignitor

 

F) Bad electronic module

Heater shuts down

High surrounding air tem-

while running.

perature causing thermal

 

limit device to shut down

 

heater.

 

Restricted air flow

REMEDY

Check voltage to electrical outlet. If voltage is good, check heater power cord for breaks.

Replace fan. See Replacing Fan, Page 13.

Replace motor. See Replacing Motor, page 12.

Repeat preparation and opera- tion instructions. See Preparation, pages 6 & 7 and Operation, pages 7, 8 & 9.

A)Check ignitor wire. Tighten or reattach loose ignitor wire. See page 5 for ignitor

wire location.

B)Set gap between ignitor electrode and target plate to .20" (0.5 cm).

C)Tighten piezo ignitor to base

of heater.

D)Replace electrode. See Replacing Electrode, page 13.

E)Replace ignitor.

F)Replace electronic module.

This can happen when running heater in temperatures above 85°F (29°C). Run heater in cooler temperatures.

Check heater inlet and outlet. Remove any obstructions.

ENGLISH

WARNING

Damaged fan

Replace fan. See Replacing Fan,

Use only in areas

 

page 13.

free of high dust

Excessive dust or debris in

Clean heater. See Maintenance,

content.

surrounding area

pages 9 & 10.

ITEM

HOW OFTEN

HOW TO

PREVENTIVE

Fan

Clean every 500 hours of

See Fan, page 10

MAINTENANCE

 

operation or as needed.

 

SCHEDULE

Electrode

Clean and regap every 500

See Electrode, page 10

 

 

hours of operation or replace

 

Continued

 

as needed.

 

11

Image 11
Contents Propane FORCED-AIR Heaters Carbon Monoxide Poisoning General SafetyInformation Minimum Heater Clearances from Combustible Materials TWO Additional Safety InformationPropane GAS FIRE/EXPLOSIONSection Contents ProductPropane Supply UnpackingNumber of Tanks Required Ventilation WarningPreparation Operation To Start HeaterExtension Cord Size Requirement OperationStorage MaintenanceTo Stop Heater Electrode MaintenanceHOW Often HOW to Symptom Possible CauseRemedy Replacing Motor ServiceProcedures Replacing Electrode Service ProceduresSpecifications Replacing FANWiring Diagram Replacement PartsChaufferettes AIR PULSÉ, AU GAZ Propane Oxycarbonisme Généralités SécuritéGardez LA Chaufferette Hors DE LA Portée DES Enfants GAZ PropaneIncendie OU Explosion Autres Renseignements DE SécuritéModèle de 40 000 btu/h Identifica Tion ProduitCoupe transversale du fonctionnement modèle 5070A illustré Alimentation EN PropaneNombre DE Bonbonnes Requises Ventilation AvertissementFonction Nement Mise en marche de la chaufferettePréparation Exigences quant au cordon de rallonge Entretien Arrêt de la chaufferetteRangement Électrode Pièce Quand Comment Indice Cause Possible SolutionMéthodes DE Dépannage Remplacement DU MoteurDonnées Techniques Remplacement DE L’HÉLICERemplacement DE L’ÉLECTRODE Modèle 5070A Schéma DE CâblageCalefactor a GAS Propano CON Ventilación Forzada Advertencia Información General Sobre Seguri DADInformación General SobreSeguridad Página Contenido SecciónSpanish Preparación VentilaciónContinuación Para encender el calefactorOperación Modelo 5070A OperaciónMantenimiento Para apagar el calefactorElectrodo Solución AdvertenciaSíntoma Causa ProbableCómo Reemplazar EL Motor DE ServicioCómo Reemplazar EL Electrodo Cómo Reemplazar EL VentiladorModelo 5070A Diagrama DE ConexionesWarranty Garantie Garantía Canada L5R Technical ServiceClientèle Servicio Técnico Assistance

5070 Series, 5075 Series specifications

Coleman, a well-known brand in outdoor recreation equipment, offers a variety of innovative tents designed to enhance camping experiences. Among its popular lines are the Coleman 5075 Series and the Coleman 5070 Series, both featuring unique attributes that cater to diverse outdoor needs.

The Coleman 5075 Series is recognized for its robust construction and weather-resistant features. One of its standout qualities is the WeatherTec system, which includes patented welded floors and inverted seams that help keep water out, ensuring a dry and comfortable camping environment even during heavy rainfall. The tent is designed with extended window awnings that provide additional protection from leaks, while also promoting ventilation to minimize condensation inside.

The 5075 Series tents are spacious, accommodating multiple campers with ease, thanks to their generous dimensions. Designed for quick and hassle-free setup, these models employ the Insta-Clip pole system, allowing for swift assembly in only a few minutes. Additionally, they incorporate a gear storage system that keeps personal items organized and within reach, enhancing the overall convenience for users.

On the other hand, the Coleman 5070 Series focuses on versatility and ease of use. One of its hallmarks is the Easy Set-Up feature, which allows campers to pitch the tent quickly without complex assembly procedures. This makes the 5070 Series particularly appealing to families and novice campers looking to maximize their outdoor time without the hassle of lengthy setups.

Technology plays a significant role in both series, particularly with the inclusion of Coleman’s unique UVGuard material, which provides enhanced protection against harmful UV rays, ensuring that campers are shielded during sunny outings. The tents are also equipped with spacious vestibules, which provide additional storage space for gear and added protection from the elements.

In terms of durability, both series maintain a sturdy design with high-quality materials engineered to withstand the rigors of outdoor use. The Coleman 5075 and 5070 Series tents are built to endure various weather conditions, making them ideal options for both weekend getaways and extended camping trips.

In summary, the Coleman 5075 and 5070 Series tents epitomize the brand's commitment to quality, convenience, and protection in outdoor camping. With thoughtful designs that incorporate weather-resistant technologies and user-friendly features, these tents provide campers with reliable shelter to enhance their outdoor adventures.