Coleman 5070 Series, 5075 Series manual Ventilation Warning, Preparation, Number of Tanks Required

Page 6

PROPANE

SUPPLY

Continued

The chart below shows the minimum number of 20-pound or larger tanks needed to run these heaters at the temperature indicated for at least 10 hours. Do not operate them with tanks smaller than indicated. Reduced performance will result.

 

 

NUMBER OF TANKS REQUIRED

Average Temperature (°F)

 

 

 

 

 

At Tank Location

32°

20°

10°

-10°

 

(0°C)

(-7°C)

(-12°C)

(-18°C)

(-23°C)

5070A751 (40,000 BTU/Hr.)

1-20#

1-40#

1-100#

2-100#

3-100#

5075A751 (80,000 BTU/Hr.)

1-100#

2-100#

2-100#

3-100#

3-100#

Less gas is vaporized at lower temperatures. You may need two or more 100-pound tanks or one larger tank in colder weather. Your local propane gas dealer will help you select the proper supply system.

VENTILATIONWARNING

Provide at least a 3-square-foot (0.3 m2) opening of fresh, outside air while running heater. If proper outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide proper outside air ventilation before running heater.

PREPARATION

WARNING

Test all gas piping and connections for leaks after preparation or servicing. Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks before using product.

1.Determine propane supply needed. (See Propane Supply).

2.Connect hose to inlet connector. Tighten firmly in clockwise direction using 9/16" wrench.

Hose and Inlet Connector

Tighten with Wrench

Continued

6

Image 6
Contents Propane FORCED-AIR Heaters General Safety InformationCarbon Monoxide Poisoning FIRE/EXPLOSION Additional Safety InformationPropane GAS Minimum Heater Clearances from Combustible Materials TWOContents Product SectionUnpacking Propane SupplyVentilation Warning PreparationNumber of Tanks Required To Start Heater OperationOperation Extension Cord Size RequirementMaintenance To Stop HeaterStorage Maintenance ElectrodeSymptom Possible Cause RemedyHOW Often HOW to Service ProceduresReplacing Motor Replacing FAN Service ProceduresSpecifications Replacing ElectrodeReplacement Parts Wiring DiagramChaufferettes AIR PULSÉ, AU GAZ Propane Généralités Sécurité OxycarbonismeAutres Renseignements DE Sécurité GAZ PropaneIncendie OU Explosion Gardez LA Chaufferette Hors DE LA Portée DES EnfantsIdentifica Tion Produit Modèle de 40 000 btu/hAlimentation EN Propane Coupe transversale du fonctionnement modèle 5070A illustréVentilation Avertissement Nombre DE Bonbonnes RequisesMise en marche de la chaufferette PréparationFonction Nement Exigences quant au cordon de rallonge Arrêt de la chaufferette RangementEntretien Électrode Indice Cause Possible Solution Pièce Quand CommentRemplacement DU Moteur Méthodes DE DépannageRemplacement DE L’HÉLICE Remplacement DE L’ÉLECTRODEDonnées Techniques Schéma DE Câblage Modèle 5070ACalefactor a GAS Propano CON Ventilación Forzada Información General Sobre Seguri DAD AdvertenciaGeneral Sobre SeguridadInformación Contenido Sección PáginaSpanish Ventilación PreparaciónPara encender el calefactor OperaciónContinuación Operación Modelo 5070APara apagar el calefactor MantenimientoElectrodo Causa Probable AdvertenciaSíntoma SoluciónDE Servicio Cómo Reemplazar EL MotorCómo Reemplazar EL Ventilador Cómo Reemplazar EL ElectrodoDiagrama DE Conexiones Modelo 5070AWarranty Garantie Garantía Assistance Technical ServiceClientèle Servicio Técnico Canada L5R

5070 Series, 5075 Series specifications

Coleman, a well-known brand in outdoor recreation equipment, offers a variety of innovative tents designed to enhance camping experiences. Among its popular lines are the Coleman 5075 Series and the Coleman 5070 Series, both featuring unique attributes that cater to diverse outdoor needs.

The Coleman 5075 Series is recognized for its robust construction and weather-resistant features. One of its standout qualities is the WeatherTec system, which includes patented welded floors and inverted seams that help keep water out, ensuring a dry and comfortable camping environment even during heavy rainfall. The tent is designed with extended window awnings that provide additional protection from leaks, while also promoting ventilation to minimize condensation inside.

The 5075 Series tents are spacious, accommodating multiple campers with ease, thanks to their generous dimensions. Designed for quick and hassle-free setup, these models employ the Insta-Clip pole system, allowing for swift assembly in only a few minutes. Additionally, they incorporate a gear storage system that keeps personal items organized and within reach, enhancing the overall convenience for users.

On the other hand, the Coleman 5070 Series focuses on versatility and ease of use. One of its hallmarks is the Easy Set-Up feature, which allows campers to pitch the tent quickly without complex assembly procedures. This makes the 5070 Series particularly appealing to families and novice campers looking to maximize their outdoor time without the hassle of lengthy setups.

Technology plays a significant role in both series, particularly with the inclusion of Coleman’s unique UVGuard material, which provides enhanced protection against harmful UV rays, ensuring that campers are shielded during sunny outings. The tents are also equipped with spacious vestibules, which provide additional storage space for gear and added protection from the elements.

In terms of durability, both series maintain a sturdy design with high-quality materials engineered to withstand the rigors of outdoor use. The Coleman 5075 and 5070 Series tents are built to endure various weather conditions, making them ideal options for both weekend getaways and extended camping trips.

In summary, the Coleman 5075 and 5070 Series tents epitomize the brand's commitment to quality, convenience, and protection in outdoor camping. With thoughtful designs that incorporate weather-resistant technologies and user-friendly features, these tents provide campers with reliable shelter to enhance their outdoor adventures.