Top Vent - Vertical Termination
MODEL | FLUE TERMINATION APPROVALS | |
|
This model is approved to use DVP or SLP Series flue pipe components. A
Approved flue system components are labeled for identifi- cation. NO OTHER FLUE SYSTEMS OR COMPONENTS MAY BE USED. Detailed installation instructions are in- cluded with each flue termination kit and should be used in conjunction with this manual.
WARNING! Risk of Fire! This gas appliance and flue assembly must be flued directly to the outside and must never be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance must use a separate flue
WARNING! Risk of Fire! DO NOT apply combustible materials beyond the minimum clearances. Comply with all minimum clearances to combustibles as specified in this manual. Overlapping material could ignite and will in- terfere with proper operation of doors and louvers.
•Horizontal sections 3 in. (76 mm) from the top of the pipe.
•Horizontal sections
•Horizontal sections 1 in. (25 mm) from sides and bottom of the pipe.
•Vertical sections 1 in. (25 mm) on all sides of pipe.
Failure to keep insulation or other material away from vent pipe may cause over heating and fire.
For alternative installations, other than depicted, contact your dealer for further information.
Straight Up Vertical Flue System
Figure 7.7 shows straight up vertical flue system approved for use on this model.
If the heater installation requires a vertical flue exceeding 14-3/4 in. (4.5 m) above the unit with no horizontal flue or elbows a vertical flue restrictor must be installed (see Figure 7.7).
V | CAP | |
MAX. RUN | ||
|
36 ft.
(10.97 m)
V1
Figure 7.7
RESTRICTOR |
PLATE |
Figure 7.8 |
30 | Heat & Glo • |
|