Heat & Glo LifeStyle owner manual CERONA-36 CERONA-42

Page 1

Owner’s Manual

Installation and Operation

Models:

CERONA-36

CERONA-42

CAUTION

DO NOT DISCARD THIS MANUAL

Important operating

Read, understand and follow

and maintenance

these instructions for safe

instructions included.

installation and operation.

Leave this manual with party responsible for use and operation.

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing proper- ty damage, personal injury, or death.

Do not store or use gasoline or other flamma- ble vapors and liquids in the vicinity of this or any other appliance.

What to do if you smell gas

-Do not try to light any appliance

-Do not touch any electrical switch. Do not use any phone in your building.

-Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

-If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

This appliance may be installed as an OEM installation in manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer’s instruc- tions and the manufactured home construction and safety standard, Title 24 CFR, Part 3280 or Standard for Installa- tion in Mobile Homes, CAN/CSA Z240MH.

This appliance is only for use with the type(s) of gas indi- cated on the rating plate.

WARNING

HOT! DO NOT TOUCH.

SEVERE BURNS MAY RESULT.

CLOTHING IGNITION MAY RESULT.

Glass and other surfaces are hot during operation and cool down.

Keep children away.

CAREFULLY SUPERVISE children in same room as appliance.

Alert children and adults to hazards of high temperatures.

Do NOT operate with protective barriers open or removed.

Keep clothing, furniture, draperies and other combustibles away.

This appliance has been supplied with an integral barrier to prevent direct contact with the fixed glass panel. Do NOT operate the appliance with the barrier removed.

Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.

In the Commonwealth of Massachusetts:

Installation must be performed by a licensed plumber or gas fitter;

See Table of Contents for location of additional Commonwealth of Massachusetts requirements.

Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies suggests NFI certified or factory-trained

professionals, or technicians supervised by an NFI certified professional.

Heat & Glo • Cerona-36, Cerona-422106-900 Rev. A • 6/06

1

Image 1 Contents
CERONA-36 CERONA-42 Homeowner Reference Information CongratulationsTable of Contents BTU Specifications High Altitude InstallationsNon-Combustible Materials Specification Combustible Materials SpecificationRequirements for the Commonwealth of Massachusetts Getting Started Design and Installation ConsiderationsInspect Appliance and Components Tools and Supplies NeededSelecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseTOP of Arch Opening Mantel ProjectionsCerona-42 Hearth ExtensionVent Termination Minimum Clearances Termination LocationsAlcove Applications ServiceTo Install the Heat Shield Install Support BracketsContinue Adding Vent Components Vent Table Key Vent Information and DiagramsUse of Elbows Measuring StandardsTop Vent Horizontal Termination Vent DiagramsCerona-36 only 0.5 ft Cerona-36 onlyTop Vent Vertical Termination Top Vent Horizontal Termination Three ElbowsV1 = 50 FT MAX .2 M 152 Pipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationInstalling Attic Shield Installing the Ceiling FirestopVertical Penetration Framing Appliance Preparation Removing Non-combustible Facing Material AssemblySecuring and Leveling the Appliance Installing Non-combustible FacingMaterial Cerona-36 Cerona-42 Installing Flue RestrictorsAssembly of Vent Sections Installing Vent PipeAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsSecuring the Vent Sections Vertical Sections Disassembly of Vent SectionsHorizontal Sections Installing the Horizontal Termination Cap Installing Heat Shield and Horizontal Termination CapHeat Shield Requirements for Horizontal Termination 14 Minimum Height from Roof to Lowest Discharge Opening Installing Roof Flashing and Vertical Termination Cap17 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarFuel Conversions Gas Connection Gas InformationGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Optional Accessories Requirements Recommendation for WireElectrical Information Properly grounded Not operate unlessJunction Box Installation Facing Material 11FinishingRisk of Fire Finishing Material OptionsFinishing Material Thickness from 3/4 in. to 1-1/4 Finishing Material Thickness greater than 1-1/4 inchPosition of board and template Clean the Appliance Appliance SetupAccessories Ember PlacementPositioning the Logs Model Cerona-36 Log Assembly LOGS-Cerona36LOG #4 SRV2106-704 Log #4 is form Model Cerona-42 Step Air Shutter Setting Glass AssemblyGrilles and Trim Before Lighting Appliance Operating InstructionsBefore operating this appliance have a qualified technician Intellifire Ignition Lighting ApplianceInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Intellifire Ignition System TroubleshootingTroubleshooting Intellifire Ignition System Before servicing Maintaining and Servicing ApplianceInspect Maintenance Tasks 16Reference Materials Appliance Dimensions DiagramModel Cerona-36 Model Cerona-42 DVP45 45 Elbow Vent Components DiagramsDVP-TRAPK1 DVP-TRAP2 DVP-TRAPK2 COOL-ADD DVP-FBHT Cerona-36 Log Set Assembly Service PartsCERONA-36 Service Parts ListCERONA-42 Cerona-42 Log Set AssemblyCERONA-42 CERONA-36 CERONA-42 Limited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyContact Information