Heat & Glo LifeStyle CERONA-42, CERONA-36 Getting Started, Design and Installation Considerations

Page 6

2 Getting Started

A. Design and Installation Considerations

Heat & Glo direct vent gas appliances are designed to op- erate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source is required.

CAUTION

Check building codes prior to installation.

Installation MUST comply with local, regional, state and national codes and regulations.

Consult local building, fire officials or authorities having jurisdiction about restrictions, installation inspection, and permits.

When planning an appliance installation, it’s necessary to determine the following information before installing:

Where the appliance is to be installed.

The vent system configuration to be used.

Gas supply piping.

Electrical wiring.

Framing and finishing details.

Whether optional accessories—devices such as a fan, wall switch, or remote control—are desired.

C.Inspect Appliance and Components

WARNING

Inspect appliance and components for damage. Damaged parts may impair safe operation.

• Do NOT install damaged components.

Do NOT install incomplete components.

Do NOT install substitute components.

Report damaged parts to dealer.

Carefully remove the appliance and components from the packaging.

The vent system components and trim doors are shipped in separate packages.

The gas logs may be packaged separately and must be field installed.

Report to your dealer any parts damaged in shipment, particularly the condition of the glass.

Read all of the instructions before starting the in- stallation. Follow these instructions carefully dur- ing the installation to ensure maximum safety and benefit.

WARNING

 

WARNING

Keep appliance dry.

 

Hearth & Home Technologies disclaims

• Mold or rust may cause odors.

 

any responsibility for, and the warranty will

• Water may damage controls.

 

be voided by, the following actions:

 

 

• Installation and use of any damaged appliance or vent

B. Tools and Supplies Needed

 

system component.

Modification of the appliance or vent system.

Before beginning the installation be sure that the following

• Installation other than as instructed by Hearth & Home

tools and building supplies are available.

 

Technologies.

Reciprocating saw

Framing material

• Improper positioning of the gas logs or the glass door.

Installation and/or use of any component part not

Pliers

Hi temp caulking material

 

approved by Hearth & Home Technologies.

Hammer

Gloves

 

Any such action may cause a fire hazard.

Phillips screwdriver

Framing square

 

 

Flat blade screwdriver

Electric drill and bits (1/4 in.)

 

 

Plumb line

Safety glasses

 

 

Level

1/2 - 3/4 inch length, #6 or #8 Self-drilling screws

Manometer

Voltmeter

 

 

Tape measure

Noncorrosive leak check solution

 

 

One 1/4 inch female connection (for optional fan).

6

Heat & Glo • Cerona-36, Cerona-422106-900 Rev. A • 6/06

Image 6
Contents CERONA-36 CERONA-42 Congratulations Homeowner Reference InformationTable of Contents Non-Combustible Materials Specification High Altitude InstallationsBTU Specifications Combustible Materials SpecificationRequirements for the Commonwealth of Massachusetts Inspect Appliance and Components Design and Installation ConsiderationsGetting Started Tools and Supplies NeededFraming and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel Projections TOP of Arch OpeningHearth Extension Cerona-42Termination Locations Vent Termination Minimum ClearancesService Alcove ApplicationsInstall Support Brackets To Install the Heat ShieldContinue Adding Vent Components Use of Elbows Vent Information and DiagramsVent Table Key Measuring StandardsCerona-36 only 0.5 ft Vent DiagramsTop Vent Horizontal Termination Cerona-36 onlyTop Vent Horizontal Termination Three Elbows Top Vent Vertical TerminationV1 = 50 FT MAX .2 M 152 Wall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationInstalling the Ceiling Firestop Installing Attic ShieldVertical Penetration Framing Removing Non-combustible Facing Material Assembly Appliance PreparationInstalling Non-combustible Facing Securing and Leveling the ApplianceMaterial Installing Flue Restrictors Cerona-36 Cerona-42Attaching Vent to the Firebox Assembly Installing Vent PipeAssembly of Vent Sections Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsDisassembly of Vent Sections Securing the Vent Sections Vertical SectionsHorizontal Sections Installing Heat Shield and Horizontal Termination Cap Installing the Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Installing Roof Flashing and Vertical Termination Cap 14 Minimum Height from Roof to Lowest Discharge OpeningAssembling and Installing Storm Collar 17 Assembling the Storm Collar Around the PipeGas Pressures Gas InformationFuel Conversions Gas Connection Pressure Natural Gas PropaneHigh Altitude Installations Recommendation for Wire Optional Accessories RequirementsElectrical Information Not operate unless Properly groundedJunction Box Installation 11Finishing Facing MaterialFinishing Material Thickness from 3/4 in. to 1-1/4 Finishing Material OptionsRisk of Fire Finishing Material Thickness greater than 1-1/4 inchPosition of board and template Accessories Appliance SetupClean the Appliance Ember PlacementLog Assembly LOGS-Cerona36 Positioning the Logs Model Cerona-36LOG #4 SRV2106-704 Log #4 is form Model Cerona-42 Step Glass Assembly Air Shutter SettingGrilles and Trim Operating Instructions Before Lighting ApplianceBefore operating this appliance have a qualified technician Lighting Appliance Intellifire IgnitionFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Intellifire Ignition SystemTroubleshooting Intellifire Ignition System Maintaining and Servicing Appliance Before servicingInspect Maintenance Tasks Appliance Dimensions Diagram 16Reference MaterialsModel Cerona-36 Model Cerona-42 Vent Components Diagrams DVP45 45 ElbowDVP-TRAPK1 DVP-TRAP2 DVP-TRAPK2 COOL-ADD DVP-FBHT Service Parts Cerona-36 Log Set AssemblyService Parts List CERONA-36Cerona-42 Log Set Assembly CERONA-42CERONA-42 CERONA-36 CERONA-42 Limited Lifetime Warranty Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsContact Information
Related manuals
Manual 64 pages 10.74 Kb Manual 1 pages 2.44 Kb

CERONA-42, CERONA-36 specifications

The Heat & Glo LifeStyle CERONA-36 and CERONA-42 are elegant gas fireplaces designed to enhance the ambiance of any living space while providing effective heating solutions. These models stand out due to their sleek design and innovative technologies that cater to modern homeowners seeking both comfort and style.

One of the primary features of the CERONA series is their clean, contemporary aesthetic. The linear design maximizes the display of flames and minimizes visual distractions, making them a focal point in any room. With options for various finishes and customizable media, including glass and logs, homeowners can truly personalize their fireplace to match their décor.

The CERONA-36 and CERONA-42 are equipped with advanced burner technology that ensures an exceptional flame presentation. The high-efficiency burners not only produce beautiful flames but also optimize heat output while maintaining energy efficiency. These fireplaces are designed to provide warmth without sacrificing environmental consciousness, making them an ideal choice for eco-aware consumers.

Both models come with Heat & Glo's patented IntelliFire Technology, which allows for adaptive ignition and reliable operation. This technology ensures that the fireplace ignites quickly and safely, providing peace of mind for users. Additionally, the remote control feature allows for easy operation from anywhere in the room, enhancing convenience when it comes to controlling the temperature and ambiance.

The CERONA series also incorporates a unique Power Vent technology. This enables the fireplace to vent up to 40 feet horizontally and vertically, offering flexibility in installation and allowing for greater design possibilities for any space in the home.

Moreover, the fireplaces are designed with sound-dampening features that reduce operational noise, ensuring a peaceful ambiance while maximizing the visual experience of dancing flames.

The straightforward maintenance and cleaning requirements of the CERONA-36 and CERONA-42 further contribute to their appeal. With a user-friendly design, these fireplaces simplify upkeep, making them suitable for busy lifestyles.

In summary, the Heat & Glo LifeStyle CERONA-36 and CERONA-42 gas fireplaces are remarkable heating solutions that combine aesthetics, technology, and user convenience. Their modern design, efficient operation, and adaptable installation options make them a valuable addition to any contemporary home, ensuring both warmth and elegance for years to come.