2. Top Vent - Vertical Termination - (continued)

Two Elbows

V1 + V2

Minimum

H1 Maximum

Cerona-36 ONLY > 0.5 ft

152 mm

2 ft

610 mm

 

 

1 ft

305 mm

2 ft

610 mm

 

2 ft

610 mm

5 ft

1.5 m

 

3 ft

914 mm

8 ft

2.4 m

 

4 ft

1.2 m

11 ft

3.4 m

 

5 ft

1.5 m

14 ft

4.3 m

 

V2

1.8 m

17 ft

5.2 m

 

6 ft

 

7 ft

2.1 m

20 ft

6.1 m

 

8 ft

2.4 m

23 ft

7.0 m

 

 

H1 = 23 ft (7.0 m) Max.

 

V1 + V2+ H1 = 63 ft (19.2 m) Max.

V1

H1

Figure 5.7

Minimal Vertical Vent

Model

ft.

mm

Cerona-36

0.5

152

Cerona-42

1

305

NOTE: Must have a minimum vertical vent before attaching a 90o elbow to the unit. See chart.

Three Elbows

 

 

 

V1 + V2 Minimum

H1 + H2 Maximum

 

 

Cerona-36 ONLY >

0.5 ft

 

 

152 mm

3 ft

914 mm

 

 

 

1 ft

 

 

305 mm

4 ft

1.2 m

 

 

 

2 ft

 

 

610 mm

7 ft

2.1 m

 

 

 

 

 

 

 

 

3 ft

 

 

914 mm

10 ft

3.0 m

 

 

 

4 ft

 

 

1.2 m

13 ft

4.0 m

V2

 

 

 

 

 

 

 

 

5 ft

 

 

1.5 m

16 ft

4.9 m

 

 

 

 

 

 

 

 

6 ft

 

 

1.8 m

19 ft

5.8 m

 

 

 

7 ft

 

 

2.1 m

22 ft

6.7 m

 

 

 

 

 

 

 

 

 

H1

+ H2 = 22 ft (6.7 m) Max.

 

 

 

 

V1+ V2

+ H1 + H2 = 62 ft (18.9 m) Max.

H1

H2

V1

INSTALLED

HORIZONTALLY

Minimal Vertical Vent

Model

ft.

mm

Cerona-36

0.5

152

Cerona-42

1

305

NOTE: Must have a minimum vertical vent before attaching a 90o elbow to the unit. See chart.

Figure 5.8

Heat & Glo • Cerona-36, Cerona-422106-900 Rev. A • 6/06

17

Image 17
Contents CERONA-36 CERONA-42 Homeowner Reference Information CongratulationsTable of Contents BTU Specifications High Altitude InstallationsNon-Combustible Materials Specification Combustible Materials SpecificationRequirements for the Commonwealth of Massachusetts Getting Started Design and Installation ConsiderationsInspect Appliance and Components Tools and Supplies NeededSelecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseTOP of Arch Opening Mantel ProjectionsCerona-42 Hearth ExtensionVent Termination Minimum Clearances Termination LocationsAlcove Applications ServiceContinue Adding Vent Components Install Support BracketsTo Install the Heat Shield Vent Table Key Vent Information and DiagramsUse of Elbows Measuring StandardsTop Vent Horizontal Termination Vent DiagramsCerona-36 only 0.5 ft Cerona-36 onlyV1 = 50 FT MAX .2 M Top Vent Horizontal Termination Three ElbowsTop Vent Vertical Termination 152 Pipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationVertical Penetration Framing Installing the Ceiling FirestopInstalling Attic Shield Appliance Preparation Removing Non-combustible Facing Material AssemblyMaterial Installing Non-combustible FacingSecuring and Leveling the Appliance Cerona-36 Cerona-42 Installing Flue RestrictorsAssembly of Vent Sections Installing Vent PipeAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsHorizontal Sections Disassembly of Vent SectionsSecuring the Vent Sections Vertical Sections Heat Shield Requirements for Horizontal Termination Installing Heat Shield and Horizontal Termination CapInstalling the Horizontal Termination Cap 14 Minimum Height from Roof to Lowest Discharge Opening Installing Roof Flashing and Vertical Termination Cap17 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarFuel Conversions Gas Connection Gas InformationGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Electrical Information Recommendation for WireOptional Accessories Requirements Properly grounded Not operate unlessJunction Box Installation Facing Material 11FinishingRisk of Fire Finishing Material OptionsFinishing Material Thickness from 3/4 in. to 1-1/4 Finishing Material Thickness greater than 1-1/4 inchPosition of board and template Clean the Appliance Appliance SetupAccessories Ember PlacementPositioning the Logs Model Cerona-36 Log Assembly LOGS-Cerona36LOG #4 SRV2106-704 Log #4 is form Model Cerona-42 Step Grilles and Trim Glass AssemblyAir Shutter Setting Before operating this appliance have a qualified technician Operating InstructionsBefore Lighting Appliance Intellifire Ignition Lighting ApplianceAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Intellifire Ignition System TroubleshootingTroubleshooting Intellifire Ignition System Before servicing Maintaining and Servicing ApplianceInspect Maintenance Tasks Model Cerona-36 Model Cerona-42 Appliance Dimensions Diagram16Reference Materials DVP45 45 Elbow Vent Components DiagramsDVP-TRAPK1 DVP-TRAP2 DVP-TRAPK2 COOL-ADD DVP-FBHT Cerona-36 Log Set Assembly Service PartsCERONA-36 Service Parts ListCERONA-42 Cerona-42 Log Set AssemblyCERONA-42 CERONA-36 CERONA-42 Limited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyContact Information
Related manuals
Manual 64 pages 10.74 Kb Manual 1 pages 2.44 Kb

CERONA-42, CERONA-36 specifications

The Heat & Glo LifeStyle CERONA-36 and CERONA-42 are elegant gas fireplaces designed to enhance the ambiance of any living space while providing effective heating solutions. These models stand out due to their sleek design and innovative technologies that cater to modern homeowners seeking both comfort and style.

One of the primary features of the CERONA series is their clean, contemporary aesthetic. The linear design maximizes the display of flames and minimizes visual distractions, making them a focal point in any room. With options for various finishes and customizable media, including glass and logs, homeowners can truly personalize their fireplace to match their décor.

The CERONA-36 and CERONA-42 are equipped with advanced burner technology that ensures an exceptional flame presentation. The high-efficiency burners not only produce beautiful flames but also optimize heat output while maintaining energy efficiency. These fireplaces are designed to provide warmth without sacrificing environmental consciousness, making them an ideal choice for eco-aware consumers.

Both models come with Heat & Glo's patented IntelliFire Technology, which allows for adaptive ignition and reliable operation. This technology ensures that the fireplace ignites quickly and safely, providing peace of mind for users. Additionally, the remote control feature allows for easy operation from anywhere in the room, enhancing convenience when it comes to controlling the temperature and ambiance.

The CERONA series also incorporates a unique Power Vent technology. This enables the fireplace to vent up to 40 feet horizontally and vertically, offering flexibility in installation and allowing for greater design possibilities for any space in the home.

Moreover, the fireplaces are designed with sound-dampening features that reduce operational noise, ensuring a peaceful ambiance while maximizing the visual experience of dancing flames.

The straightforward maintenance and cleaning requirements of the CERONA-36 and CERONA-42 further contribute to their appeal. With a user-friendly design, these fireplaces simplify upkeep, making them suitable for busy lifestyles.

In summary, the Heat & Glo LifeStyle CERONA-36 and CERONA-42 gas fireplaces are remarkable heating solutions that combine aesthetics, technology, and user convenience. Their modern design, efficient operation, and adaptable installation options make them a valuable addition to any contemporary home, ensuring both warmth and elegance for years to come.