Heat & Glo LifeStyle CERONA-42, CERONA-36 Installing Flue Restrictors, Cerona-36 Cerona-42

Page 22

Attach the left and right side pieces to the framing mem- bers. (See Figure 7.3).

NON-COMBUSTIBLE

FACING MATERIAL

B

1in.

(25 mm)

A

 

 

A

B

Cerona-36

in.

43-5/8

50-3/16

mm

1108

1275

 

Cerona-42

in.

50-5/8

54-3/8

mm

1286

1381

 

Figure 7.4 Complete Installation of Non-combustible Facing Material

Use a wet or dry towel or soft brush to remove dust or dirt from facing material.

Apply a non-combustible adhesive to attach tile, stone or other non-combustible finishing materials per manufacturer’s instructions.

D. Installing Flue Restrictors

Locate the flue restrictor and two screws inside the manual bag. Use the following table to determine which restrictors to use for the vent run.

Vent Run Vertical

 

15 ft. - 50 ft.

 

 

 

Cerona-36

NG

1-1/4

 

 

 

Cerona-42

NG

1-1/4

 

 

 

Mount the flue restrictor above the flapper door using two screws (see Figure 7.5).

EXHAUST

 

FLUE

COLLAR

 

 

RESTRICTOR

 

 

 

FIREBOX

 

 

TOP OF

 

 

FLAPPER

FIREPLACE

EXHAUST

 

DOOR

 

PORT

 

 

 

 

EXHAUST

FLUE

 

 

COLLAR

 

 

RESTRICTOR

 

 

 

 

 

SCREWS

FLAPPER

 

 

 

 

 

 

DOOR

 

 

SCREWS (2)

 

 

BOTTOM

 

 

 

OF FIREPLACE

 

EXHAUST

 

 

 

PORT

Figure 7.5

 

 

 

22

Heat & Glo • Cerona-36, Cerona-422106-900 Rev. A • 6/06

Image 22
Contents CERONA-36 CERONA-42 Congratulations Homeowner Reference InformationTable of Contents Non-Combustible Materials Specification High Altitude InstallationsBTU Specifications Combustible Materials SpecificationRequirements for the Commonwealth of Massachusetts Inspect Appliance and Components Design and Installation ConsiderationsGetting Started Tools and Supplies NeededFraming and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel Projections TOP of Arch OpeningHearth Extension Cerona-42Termination Locations Vent Termination Minimum ClearancesService Alcove ApplicationsTo Install the Heat Shield Install Support BracketsContinue Adding Vent Components Use of Elbows Vent Information and DiagramsVent Table Key Measuring StandardsCerona-36 only 0.5 ft Vent DiagramsTop Vent Horizontal Termination Cerona-36 onlyTop Vent Vertical Termination Top Vent Horizontal Termination Three ElbowsV1 = 50 FT MAX .2 M 152 Wall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationInstalling Attic Shield Installing the Ceiling FirestopVertical Penetration Framing Removing Non-combustible Facing Material Assembly Appliance PreparationSecuring and Leveling the Appliance Installing Non-combustible FacingMaterial Installing Flue Restrictors Cerona-36 Cerona-42Attaching Vent to the Firebox Assembly Installing Vent PipeAssembly of Vent Sections Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsSecuring the Vent Sections Vertical Sections Disassembly of Vent SectionsHorizontal Sections Installing the Horizontal Termination Cap Installing Heat Shield and Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Installing Roof Flashing and Vertical Termination Cap 14 Minimum Height from Roof to Lowest Discharge OpeningAssembling and Installing Storm Collar 17 Assembling the Storm Collar Around the PipeGas Pressures Gas InformationFuel Conversions Gas Connection Pressure Natural Gas PropaneHigh Altitude Installations Optional Accessories Requirements Recommendation for WireElectrical Information Not operate unless Properly groundedJunction Box Installation 11Finishing Facing MaterialFinishing Material Thickness from 3/4 in. to 1-1/4 Finishing Material OptionsRisk of Fire Finishing Material Thickness greater than 1-1/4 inchPosition of board and template Accessories Appliance SetupClean the Appliance Ember PlacementLog Assembly LOGS-Cerona36 Positioning the Logs Model Cerona-36LOG #4 SRV2106-704 Log #4 is form Model Cerona-42 Step Air Shutter Setting Glass AssemblyGrilles and Trim Before Lighting Appliance Operating InstructionsBefore operating this appliance have a qualified technician Lighting Appliance Intellifire IgnitionInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Troubleshooting Intellifire Ignition SystemTroubleshooting Intellifire Ignition System Maintaining and Servicing Appliance Before servicingInspect Maintenance Tasks 16Reference Materials Appliance Dimensions DiagramModel Cerona-36 Model Cerona-42 Vent Components Diagrams DVP45 45 ElbowDVP-TRAPK1 DVP-TRAP2 DVP-TRAPK2 COOL-ADD DVP-FBHT Service Parts Cerona-36 Log Set AssemblyService Parts List CERONA-36Cerona-42 Log Set Assembly CERONA-42CERONA-42 CERONA-36 CERONA-42 Limited Lifetime Warranty Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsContact Information
Related manuals
Manual 64 pages 10.74 Kb Manual 1 pages 2.44 Kb

CERONA-42, CERONA-36 specifications

The Heat & Glo LifeStyle CERONA-36 and CERONA-42 are elegant gas fireplaces designed to enhance the ambiance of any living space while providing effective heating solutions. These models stand out due to their sleek design and innovative technologies that cater to modern homeowners seeking both comfort and style.

One of the primary features of the CERONA series is their clean, contemporary aesthetic. The linear design maximizes the display of flames and minimizes visual distractions, making them a focal point in any room. With options for various finishes and customizable media, including glass and logs, homeowners can truly personalize their fireplace to match their décor.

The CERONA-36 and CERONA-42 are equipped with advanced burner technology that ensures an exceptional flame presentation. The high-efficiency burners not only produce beautiful flames but also optimize heat output while maintaining energy efficiency. These fireplaces are designed to provide warmth without sacrificing environmental consciousness, making them an ideal choice for eco-aware consumers.

Both models come with Heat & Glo's patented IntelliFire Technology, which allows for adaptive ignition and reliable operation. This technology ensures that the fireplace ignites quickly and safely, providing peace of mind for users. Additionally, the remote control feature allows for easy operation from anywhere in the room, enhancing convenience when it comes to controlling the temperature and ambiance.

The CERONA series also incorporates a unique Power Vent technology. This enables the fireplace to vent up to 40 feet horizontally and vertically, offering flexibility in installation and allowing for greater design possibilities for any space in the home.

Moreover, the fireplaces are designed with sound-dampening features that reduce operational noise, ensuring a peaceful ambiance while maximizing the visual experience of dancing flames.

The straightforward maintenance and cleaning requirements of the CERONA-36 and CERONA-42 further contribute to their appeal. With a user-friendly design, these fireplaces simplify upkeep, making them suitable for busy lifestyles.

In summary, the Heat & Glo LifeStyle CERONA-36 and CERONA-42 gas fireplaces are remarkable heating solutions that combine aesthetics, technology, and user convenience. Their modern design, efficient operation, and adaptable installation options make them a valuable addition to any contemporary home, ensuring both warmth and elegance for years to come.