Heat & Glo LifeStyle CERONA-42 Top Vent Horizontal Termination Three Elbows, V1 = 50 FT MAX .2 M

Page 16

1. Top Vent - Horizontal Termination - (continued)

Three Elbows

V1+V2 Minimum

H1 + H2 Maximum

Cerona-36 ONLY > 0.5 ft

152 mm

 

3 ft

914 mm

 

1 ft

305 mm

 

4 ft

1.2 m

 

2 ft

610 mm

 

7 ft

2.1 m

 

3 ft

914 mm

 

10 ft

3.0 m

 

4 ft

1.2 m

 

13

4.0 m

 

5 ft

1.5 m

 

16

4.9 m

 

6 ft

1.8 m

 

17

5.2 m

 

7 ft

2.1m

 

22

6.7 m

 

H1

+ H2 = 22 ft (6.7 m) Max.

 

V1+ V2 + H1 + H2

= 62 ft (18.9 m)

 

 

 

Max.

 

Minimal Vertical Vent

Model

ft.

mm

Cerona-36

0.5

152

Cerona-42

1

305

NOTE: Must have a minimum

vertical vent before attaching a

90o elbow to the unit. See chart.

Figure 5.5

 

 

2. Top Vent - Vertical Termination

CAP

Straight Up Vertical Venting

 

V1 = 50 FT MAX. (15.2 M)

NOTE: On vertical venting config- urations install the flue restrictor found in the appliance manual bag. Follow flue restrictor instructions in Section 7D.

V1

Figure 5.6

16

Heat & Glo • Cerona-36, Cerona-422106-900 Rev. A • 6/06

Image 16
Contents CERONA-36 CERONA-42 Congratulations Homeowner Reference InformationTable of Contents High Altitude Installations BTU SpecificationsNon-Combustible Materials Specification Combustible Materials SpecificationRequirements for the Commonwealth of Massachusetts Design and Installation Considerations Getting StartedInspect Appliance and Components Tools and Supplies NeededFraming and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel Projections TOP of Arch OpeningHearth Extension Cerona-42Termination Locations Vent Termination Minimum ClearancesService Alcove ApplicationsTo Install the Heat Shield Install Support BracketsContinue Adding Vent Components Vent Information and Diagrams Vent Table KeyUse of Elbows Measuring StandardsVent Diagrams Top Vent Horizontal TerminationCerona-36 only 0.5 ft Cerona-36 onlyTop Vent Vertical Termination Top Vent Horizontal Termination Three ElbowsV1 = 50 FT MAX .2 M 152 Vent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationInstalling Attic Shield Installing the Ceiling FirestopVertical Penetration Framing Removing Non-combustible Facing Material Assembly Appliance PreparationSecuring and Leveling the Appliance Installing Non-combustible FacingMaterial Installing Flue Restrictors Cerona-36 Cerona-42Installing Vent Pipe Assembly of Vent SectionsAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsSecuring the Vent Sections Vertical Sections Disassembly of Vent SectionsHorizontal Sections Installing the Horizontal Termination Cap Installing Heat Shield and Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Installing Roof Flashing and Vertical Termination Cap 14 Minimum Height from Roof to Lowest Discharge OpeningAssembling and Installing Storm Collar 17 Assembling the Storm Collar Around the PipeGas Information Fuel Conversions Gas ConnectionGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Optional Accessories Requirements Recommendation for WireElectrical Information Not operate unless Properly groundedJunction Box Installation 11Finishing Facing MaterialFinishing Material Options Risk of FireFinishing Material Thickness from 3/4 in. to 1-1/4 Finishing Material Thickness greater than 1-1/4 inchPosition of board and template Appliance Setup Clean the ApplianceAccessories Ember PlacementLog Assembly LOGS-Cerona36 Positioning the Logs Model Cerona-36LOG #4 SRV2106-704 Log #4 is form Model Cerona-42 Step Air Shutter Setting Glass AssemblyGrilles and Trim Before Lighting Appliance Operating InstructionsBefore operating this appliance have a qualified technician Lighting Appliance Intellifire IgnitionInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Troubleshooting Intellifire Ignition SystemTroubleshooting Intellifire Ignition System Maintaining and Servicing Appliance Before servicingInspect Maintenance Tasks 16Reference Materials Appliance Dimensions DiagramModel Cerona-36 Model Cerona-42 Vent Components Diagrams DVP45 45 ElbowDVP-TRAPK1 DVP-TRAP2 DVP-TRAPK2 COOL-ADD DVP-FBHT Service Parts Cerona-36 Log Set AssemblyService Parts List CERONA-36Cerona-42 Log Set Assembly CERONA-42CERONA-42 CERONA-36 CERONA-42 Limited Lifetime Warranty Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsContact Information
Related manuals
Manual 64 pages 10.74 Kb Manual 1 pages 2.44 Kb

CERONA-42, CERONA-36 specifications

The Heat & Glo LifeStyle CERONA-36 and CERONA-42 are elegant gas fireplaces designed to enhance the ambiance of any living space while providing effective heating solutions. These models stand out due to their sleek design and innovative technologies that cater to modern homeowners seeking both comfort and style.

One of the primary features of the CERONA series is their clean, contemporary aesthetic. The linear design maximizes the display of flames and minimizes visual distractions, making them a focal point in any room. With options for various finishes and customizable media, including glass and logs, homeowners can truly personalize their fireplace to match their décor.

The CERONA-36 and CERONA-42 are equipped with advanced burner technology that ensures an exceptional flame presentation. The high-efficiency burners not only produce beautiful flames but also optimize heat output while maintaining energy efficiency. These fireplaces are designed to provide warmth without sacrificing environmental consciousness, making them an ideal choice for eco-aware consumers.

Both models come with Heat & Glo's patented IntelliFire Technology, which allows for adaptive ignition and reliable operation. This technology ensures that the fireplace ignites quickly and safely, providing peace of mind for users. Additionally, the remote control feature allows for easy operation from anywhere in the room, enhancing convenience when it comes to controlling the temperature and ambiance.

The CERONA series also incorporates a unique Power Vent technology. This enables the fireplace to vent up to 40 feet horizontally and vertically, offering flexibility in installation and allowing for greater design possibilities for any space in the home.

Moreover, the fireplaces are designed with sound-dampening features that reduce operational noise, ensuring a peaceful ambiance while maximizing the visual experience of dancing flames.

The straightforward maintenance and cleaning requirements of the CERONA-36 and CERONA-42 further contribute to their appeal. With a user-friendly design, these fireplaces simplify upkeep, making them suitable for busy lifestyles.

In summary, the Heat & Glo LifeStyle CERONA-36 and CERONA-42 gas fireplaces are remarkable heating solutions that combine aesthetics, technology, and user convenience. Their modern design, efficient operation, and adaptable installation options make them a valuable addition to any contemporary home, ensuring both warmth and elegance for years to come.