Heat & Glo LifeStyle CERONA-36, CERONA-42 owner manual Junction Box Installation

Page 33

D.Junction Box Installation

If the box is being wired from the OUTSIDE of the appliance:

Loosen screw on the Romex connector, feed the necessary length of wire through the connector and tighten the screw.

Make all necessary wire connections and reattach the cover plate to the outer shell.

If the box is being wired from the INSIDE of the appliance:

Remove the screw attaching the junction box to the outer shell, rotate the junction box inward to disengage it from the outer shell (see Figure 10.2).

Loosen the screw on the Romex connector, feed the necessary length of wire through the con- nector and tighten the screw.

Pull the electrical wires from outside the appliance through this opening into the valve compartment.

Make all necessary wire connections to the receptacle and assemble the receptacle and cover to the junction box.

 

 

HEAT SHIELD

14/2WG

 

 

 

 

 

 

STRAIN RELIEF

 

 

 

CONNECTOR

 

 

 

FRONT OF

 

 

BLACK

FIREPLACE

 

WHITE

 

 

 

 

COPPER GROUND

 

 

 

ATTACHED TO

JUNCTION

 

GROUND

 

SCREW WITH

BOX

 

GROUND WIRE

 

GROUND WIRE

 

 

INSIDE BOX

 

 

 

BOTTOM PAN

 

 

 

NOTE: Do NOT wire

 

 

110VAC to wall switch.

Figure

10.2

Junction Box Detail

 

Heat & Glo • Cerona-36, Cerona-422106-900 Rev. A • 6/06

33

Image 33
Contents CERONA-36 CERONA-42 Homeowner Reference Information CongratulationsTable of Contents BTU Specifications High Altitude InstallationsNon-Combustible Materials Specification Combustible Materials SpecificationRequirements for the Commonwealth of Massachusetts Getting Started Design and Installation ConsiderationsInspect Appliance and Components Tools and Supplies NeededSelecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseTOP of Arch Opening Mantel ProjectionsCerona-42 Hearth ExtensionVent Termination Minimum Clearances Termination LocationsAlcove Applications ServiceInstall Support Brackets To Install the Heat ShieldContinue Adding Vent Components Vent Table Key Vent Information and DiagramsUse of Elbows Measuring StandardsTop Vent Horizontal Termination Vent DiagramsCerona-36 only 0.5 ft Cerona-36 onlyTop Vent Horizontal Termination Three Elbows Top Vent Vertical TerminationV1 = 50 FT MAX .2 M 152 Pipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationInstalling the Ceiling Firestop Installing Attic ShieldVertical Penetration Framing Appliance Preparation Removing Non-combustible Facing Material AssemblyInstalling Non-combustible Facing Securing and Leveling the ApplianceMaterial Cerona-36 Cerona-42 Installing Flue RestrictorsAssembly of Vent Sections Installing Vent PipeAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsDisassembly of Vent Sections Securing the Vent Sections Vertical SectionsHorizontal Sections Installing Heat Shield and Horizontal Termination Cap Installing the Horizontal Termination CapHeat Shield Requirements for Horizontal Termination 14 Minimum Height from Roof to Lowest Discharge Opening Installing Roof Flashing and Vertical Termination Cap17 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarFuel Conversions Gas Connection Gas InformationGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Recommendation for Wire Optional Accessories RequirementsElectrical Information Properly grounded Not operate unlessJunction Box Installation Facing Material 11FinishingRisk of Fire Finishing Material OptionsFinishing Material Thickness from 3/4 in. to 1-1/4 Finishing Material Thickness greater than 1-1/4 inchPosition of board and template Clean the Appliance Appliance SetupAccessories Ember PlacementPositioning the Logs Model Cerona-36 Log Assembly LOGS-Cerona36LOG #4 SRV2106-704 Log #4 is form Model Cerona-42 Step Glass Assembly Air Shutter SettingGrilles and Trim Operating Instructions Before Lighting ApplianceBefore operating this appliance have a qualified technician Intellifire Ignition Lighting ApplianceFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Intellifire Ignition System TroubleshootingTroubleshooting Intellifire Ignition System Before servicing Maintaining and Servicing ApplianceInspect Maintenance Tasks Appliance Dimensions Diagram 16Reference MaterialsModel Cerona-36 Model Cerona-42 DVP45 45 Elbow Vent Components DiagramsDVP-TRAPK1 DVP-TRAP2 DVP-TRAPK2 COOL-ADD DVP-FBHT Cerona-36 Log Set Assembly Service PartsCERONA-36 Service Parts ListCERONA-42 Cerona-42 Log Set AssemblyCERONA-42 CERONA-36 CERONA-42 Limited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyContact Information
Related manuals
Manual 64 pages 10.74 Kb Manual 1 pages 2.44 Kb

CERONA-42, CERONA-36 specifications

The Heat & Glo LifeStyle CERONA-36 and CERONA-42 are elegant gas fireplaces designed to enhance the ambiance of any living space while providing effective heating solutions. These models stand out due to their sleek design and innovative technologies that cater to modern homeowners seeking both comfort and style.

One of the primary features of the CERONA series is their clean, contemporary aesthetic. The linear design maximizes the display of flames and minimizes visual distractions, making them a focal point in any room. With options for various finishes and customizable media, including glass and logs, homeowners can truly personalize their fireplace to match their décor.

The CERONA-36 and CERONA-42 are equipped with advanced burner technology that ensures an exceptional flame presentation. The high-efficiency burners not only produce beautiful flames but also optimize heat output while maintaining energy efficiency. These fireplaces are designed to provide warmth without sacrificing environmental consciousness, making them an ideal choice for eco-aware consumers.

Both models come with Heat & Glo's patented IntelliFire Technology, which allows for adaptive ignition and reliable operation. This technology ensures that the fireplace ignites quickly and safely, providing peace of mind for users. Additionally, the remote control feature allows for easy operation from anywhere in the room, enhancing convenience when it comes to controlling the temperature and ambiance.

The CERONA series also incorporates a unique Power Vent technology. This enables the fireplace to vent up to 40 feet horizontally and vertically, offering flexibility in installation and allowing for greater design possibilities for any space in the home.

Moreover, the fireplaces are designed with sound-dampening features that reduce operational noise, ensuring a peaceful ambiance while maximizing the visual experience of dancing flames.

The straightforward maintenance and cleaning requirements of the CERONA-36 and CERONA-42 further contribute to their appeal. With a user-friendly design, these fireplaces simplify upkeep, making them suitable for busy lifestyles.

In summary, the Heat & Glo LifeStyle CERONA-36 and CERONA-42 gas fireplaces are remarkable heating solutions that combine aesthetics, technology, and user convenience. Their modern design, efficient operation, and adaptable installation options make them a valuable addition to any contemporary home, ensuring both warmth and elegance for years to come.