Heat & Glo LifeStyle CERONA-42, CERONA-36 owner manual Constructing the Appliance Chase, Clearances

Page 8

B.Constructing the Appliance Chase

A chase is a vertical boxlike structure built to enclose the gas appliance and/or its vent system. Vertical vents that run on the outside of a building may be, but are not re- quired to be, installed inside a chase.

Construction of the chase may vary with the type of building. These instructions are not substitutes for the requirements of local building codes. Local building codes MUST be checked.

Chases should be constructed in the manner of all outside walls of the home to prevent cold air drafting problems. The chase should not break the outside building envelope in any manner.

Walls, ceiling, base plate and cantilever floor of the chase should be insulated. Vapor and air infiltration barriers should be installed in the chase as per regional codes for the rest of the home. Additionally, in regions where cold air infiltra- tion may be an issue, the inside surfaces may be sheetrocked and taped for maximum air tightness.

To further prevent drafts, the wall shield and ceiling firestops should be caulked with high temperature caulk to seal gaps. Gas line holes and other openings should be caulked with

high temp caulk or stuffed with unfaced insulation. If the appliance is being installed on a cement slab, a layer of plywood may be placed underneath to prevent conducting cold up into the room.

C.Clearances

WARNING

Fire Risk.

Odor Risk.

Install appliance on hard metal or wood

surfaces extending full width and depth of appliance.

Do NOT install appliance directly on carpeting, vinyl, tile or any combustible material other than wood.

WARNING

Fire Risk.

Construct chase to all clearance specifications in manual.

Locate and install appliance to all clearance specifications in manual

A

E

B

F

C

 

G

H

J

 

D

I

 

 

 

 

 

 

CLEARANCES TO COMBUSTIBLES:

 

 

 

 

 

 

 

 

A

B

C

D

E

F

G

H

I

J

 

 

 

 

Rough

Rough

Rough

Rough

Clearance to

Non-Combustible

Combustible

Behind

Sides of

Front of

 

 

 

 

Opening

Opening

Opening

Opening

Ceiling from Top

 

 

 

 

(Vent Pipe)

(Height)

(Depth)

(Width)

of Arch Opening

Floor

Flooring

Appliance

Appliance

Appliance

 

 

Cerona-36

in

10

50-1/2

22-1/4

42-1/8

49

0

8

1/2

1/2

36

 

 

mm

254

1283

565

1070

1245

0

203

13

13

914

 

 

 

 

 

Cerona-42

in

10

54-1/2

22-1/4

49-1/8

45-1/4

0

8

1/2

1/2

36

 

 

mm

254

1384

565

1248

1149

0

203

13

13

914

 

Figure 3.2 Clearances to Combustibles

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

Heat & Glo • Cerona-36, Cerona-422106-900 Rev. A • 6/06

 

 

 

 

Image 8
Contents CERONA-36 CERONA-42 Congratulations Homeowner Reference InformationTable of Contents High Altitude Installations BTU SpecificationsNon-Combustible Materials Specification Combustible Materials SpecificationRequirements for the Commonwealth of Massachusetts Design and Installation Considerations Getting StartedInspect Appliance and Components Tools and Supplies NeededFraming and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel Projections TOP of Arch OpeningHearth Extension Cerona-42Termination Locations Vent Termination Minimum ClearancesService Alcove ApplicationsContinue Adding Vent Components Install Support BracketsTo Install the Heat Shield Vent Information and Diagrams Vent Table KeyUse of Elbows Measuring StandardsVent Diagrams Top Vent Horizontal TerminationCerona-36 only 0.5 ft Cerona-36 onlyV1 = 50 FT MAX .2 M Top Vent Horizontal Termination Three ElbowsTop Vent Vertical Termination 152 Vent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationVertical Penetration Framing Installing the Ceiling FirestopInstalling Attic Shield Removing Non-combustible Facing Material Assembly Appliance PreparationMaterial Installing Non-combustible FacingSecuring and Leveling the Appliance Installing Flue Restrictors Cerona-36 Cerona-42Installing Vent Pipe Assembly of Vent SectionsAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsHorizontal Sections Disassembly of Vent SectionsSecuring the Vent Sections Vertical Sections Heat Shield Requirements for Horizontal Termination Installing Heat Shield and Horizontal Termination CapInstalling the Horizontal Termination Cap Installing Roof Flashing and Vertical Termination Cap 14 Minimum Height from Roof to Lowest Discharge OpeningAssembling and Installing Storm Collar 17 Assembling the Storm Collar Around the PipeGas Information Fuel Conversions Gas ConnectionGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Electrical Information Recommendation for WireOptional Accessories Requirements Not operate unless Properly groundedJunction Box Installation 11Finishing Facing MaterialFinishing Material Options Risk of FireFinishing Material Thickness from 3/4 in. to 1-1/4 Finishing Material Thickness greater than 1-1/4 inchPosition of board and template Appliance Setup Clean the ApplianceAccessories Ember PlacementLog Assembly LOGS-Cerona36 Positioning the Logs Model Cerona-36LOG #4 SRV2106-704 Log #4 is form Model Cerona-42 Step Grilles and Trim Glass AssemblyAir Shutter Setting Before operating this appliance have a qualified technician Operating InstructionsBefore Lighting Appliance Lighting Appliance Intellifire IgnitionAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Troubleshooting Intellifire Ignition SystemTroubleshooting Intellifire Ignition System Maintaining and Servicing Appliance Before servicingInspect Maintenance Tasks Model Cerona-36 Model Cerona-42 Appliance Dimensions Diagram16Reference Materials Vent Components Diagrams DVP45 45 ElbowDVP-TRAPK1 DVP-TRAP2 DVP-TRAPK2 COOL-ADD DVP-FBHT Service Parts Cerona-36 Log Set AssemblyService Parts List CERONA-36Cerona-42 Log Set Assembly CERONA-42CERONA-42 CERONA-36 CERONA-42 Limited Lifetime Warranty Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsContact Information
Related manuals
Manual 64 pages 10.74 Kb Manual 1 pages 2.44 Kb

CERONA-42, CERONA-36 specifications

The Heat & Glo LifeStyle CERONA-36 and CERONA-42 are elegant gas fireplaces designed to enhance the ambiance of any living space while providing effective heating solutions. These models stand out due to their sleek design and innovative technologies that cater to modern homeowners seeking both comfort and style.

One of the primary features of the CERONA series is their clean, contemporary aesthetic. The linear design maximizes the display of flames and minimizes visual distractions, making them a focal point in any room. With options for various finishes and customizable media, including glass and logs, homeowners can truly personalize their fireplace to match their décor.

The CERONA-36 and CERONA-42 are equipped with advanced burner technology that ensures an exceptional flame presentation. The high-efficiency burners not only produce beautiful flames but also optimize heat output while maintaining energy efficiency. These fireplaces are designed to provide warmth without sacrificing environmental consciousness, making them an ideal choice for eco-aware consumers.

Both models come with Heat & Glo's patented IntelliFire Technology, which allows for adaptive ignition and reliable operation. This technology ensures that the fireplace ignites quickly and safely, providing peace of mind for users. Additionally, the remote control feature allows for easy operation from anywhere in the room, enhancing convenience when it comes to controlling the temperature and ambiance.

The CERONA series also incorporates a unique Power Vent technology. This enables the fireplace to vent up to 40 feet horizontally and vertically, offering flexibility in installation and allowing for greater design possibilities for any space in the home.

Moreover, the fireplaces are designed with sound-dampening features that reduce operational noise, ensuring a peaceful ambiance while maximizing the visual experience of dancing flames.

The straightforward maintenance and cleaning requirements of the CERONA-36 and CERONA-42 further contribute to their appeal. With a user-friendly design, these fireplaces simplify upkeep, making them suitable for busy lifestyles.

In summary, the Heat & Glo LifeStyle CERONA-36 and CERONA-42 gas fireplaces are remarkable heating solutions that combine aesthetics, technology, and user convenience. Their modern design, efficient operation, and adaptable installation options make them a valuable addition to any contemporary home, ensuring both warmth and elegance for years to come.