Heat & Glo LifeStyle CERONA-36, CERONA-42 owner manual Inspect Maintenance Tasks

Page 49

Inspect

 

Maintenance Tasks

Doors, Surrounds

1. Assess condition of screen and replace as necessary. Recommend addition of screen

and Fronts

if one is not present.

 

2.

Inspect for scratches, dents or other damage and repair as necessary.

 

 

 

 

3.

Verify no obstructions to airflow through the louvers.

 

 

 

 

4.

Verify maintenance of proper clearance to combustible household objects.

 

 

 

Gasket Seal, Glass

1. Inspect gasket seal and its condition.

Assembly and Glass

 

 

 

2.

Inspect glass panels for scratches and nicks that can lead to breakage when exposed to

 

heat.

 

3. Confirm there is no damage to glass or glass frame. Replace as necessary.

 

 

 

 

4.

Verify that latches engage properly, clip studs are not stripped, and glass attachment

 

components are intact and operating properly. Replace as necessary.

 

5.

Clean glass. Replace glass assembly if severely coated with silicate deposits that cannot

 

be removed.

Valve Compartment

1. Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these

and Firebox Top

areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided.

 

2.

Remove any foreign objects.

 

 

 

 

3.

Verify unobstructed air circulation.

 

 

 

Logs

1.

Inspect for broken, damaged, or missing logs. Replace as necessary.

 

2.

Verify correct log placement and no flame impingement causing sooting. Correct as

 

necessary.

Firebox

1.

Inspect for paint condition, warpage, corrosion or perforation. Sand and repaint as

 

necessary.

 

2.

Replace appliance if firebox has been perforated.

 

 

 

Burner Ignition and

1. Verify burner is properly secured and aligned with pilot or igniter.

Operation

 

 

 

2.

Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if

 

necessary.

 

3.

Replace ember materials with new dime-size and shape pieces. Do not block ports or

 

obstruct lighting paths.

 

4.

Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.

 

 

 

 

5.

Inspect for lifting or other flame problems.

 

 

 

 

6.

Verify air shutter is clear of dust and debris.

 

 

 

 

7.

Inspect orifice for soot, dirt or corrosion.

 

 

 

 

8.

Verify manifold and inlet pressures. Adjust regulator as required.

 

 

 

 

9.

Inspect pilot flame strength. Clean or replace orifice as necessary.

 

 

 

10. Inspect thermocouple/thermopile or IPI sensor rod for soot, corrosion and deterioration.

 

Clean with emery cloth or replace as required.

 

11. Verify millivolt output. Replace as necessary.

 

 

Venting

1. Inspect venting for blockage or obstruction such as bird nests, leaves, etc.

 

2.

Confirm that termination cap remains clear and unobstructed by plants, etc.

 

3.

Verify that termination cap clearance to subsequent construction (building additions, decks,

 

fences or sheds) has been maintained.

 

4.

Inspect for corrosion or separation.

 

5.

Verify weather stripping, sealing and flashing remains intact.

 

6.

Inspect draft shield to verify it is not bent, damaged or missing.

 

 

 

Heat & Glo • Cerona-36, Cerona-422106-900 Rev. A • 6/06

49

Image 49 Contents
CERONA-36 CERONA-42 Homeowner Reference Information CongratulationsTable of Contents BTU Specifications High Altitude InstallationsNon-Combustible Materials Specification Combustible Materials SpecificationRequirements for the Commonwealth of Massachusetts Getting Started Design and Installation ConsiderationsInspect Appliance and Components Tools and Supplies NeededSelecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseTOP of Arch Opening Mantel ProjectionsCerona-42 Hearth ExtensionVent Termination Minimum Clearances Termination LocationsAlcove Applications ServiceTo Install the Heat Shield Install Support BracketsContinue Adding Vent Components Vent Table Key Vent Information and DiagramsUse of Elbows Measuring StandardsTop Vent Horizontal Termination Vent DiagramsCerona-36 only 0.5 ft Cerona-36 onlyTop Vent Vertical Termination Top Vent Horizontal Termination Three ElbowsV1 = 50 FT MAX .2 M 152 Pipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationInstalling Attic Shield Installing the Ceiling FirestopVertical Penetration Framing Appliance Preparation Removing Non-combustible Facing Material AssemblySecuring and Leveling the Appliance Installing Non-combustible FacingMaterial Cerona-36 Cerona-42 Installing Flue RestrictorsAssembly of Vent Sections Installing Vent PipeAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsSecuring the Vent Sections Vertical Sections Disassembly of Vent SectionsHorizontal Sections Installing the Horizontal Termination Cap Installing Heat Shield and Horizontal Termination CapHeat Shield Requirements for Horizontal Termination 14 Minimum Height from Roof to Lowest Discharge Opening Installing Roof Flashing and Vertical Termination Cap17 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarFuel Conversions Gas Connection Gas InformationGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Optional Accessories Requirements Recommendation for WireElectrical Information Properly grounded Not operate unlessJunction Box Installation Facing Material 11FinishingRisk of Fire Finishing Material OptionsFinishing Material Thickness from 3/4 in. to 1-1/4 Finishing Material Thickness greater than 1-1/4 inchPosition of board and template Clean the Appliance Appliance SetupAccessories Ember PlacementPositioning the Logs Model Cerona-36 Log Assembly LOGS-Cerona36LOG #4 SRV2106-704 Log #4 is form Model Cerona-42 Step Air Shutter Setting Glass AssemblyGrilles and Trim Before Lighting Appliance Operating InstructionsBefore operating this appliance have a qualified technician Intellifire Ignition Lighting Appliance Initial Break-in Procedure Frequently Asked Questions After Appliance is Lit Intellifire Ignition System TroubleshootingTroubleshooting Intellifire Ignition System Before servicing Maintaining and Servicing ApplianceInspect Maintenance Tasks 16Reference Materials Appliance Dimensions DiagramModel Cerona-36 Model Cerona-42 DVP45 45 Elbow Vent Components DiagramsDVP-TRAPK1 DVP-TRAP2 DVP-TRAPK2 COOL-ADD DVP-FBHT Cerona-36 Log Set Assembly Service PartsCERONA-36 Service Parts ListCERONA-42 Cerona-42 Log Set AssemblyCERONA-42 CERONA-36 CERONA-42 Limited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyContact Information