Installation

Dry Contact Relay Outputs

17.1 Description

The XR2500F panel provides two programmable auxiliary SPDT relays with the two DMP Model 305 relays in K6 (Output 1) and K7 (Output 2) and a Model 431 Output Harness on the J2 6-pin Header. Each relay provides one SPDT set of contacts that can be operated by any of the functions listed below:

1)Activation by zone condition: Steady, Pulsing, Momentary, and Follow

2)Activation by 24-hour 7-day schedule: One on and one off time a day for each relay

3)Manual activation from the Security Command keypad menu

4)Communication failure

5)Armed area annunciation

6)Fire Alarm, Fire Trouble, or Supervisory

7)Ambush Alarm

8)Exit and Entry timers

9)System Ready

10)Late to Close

Refer to the XR500 Series Programming Guide (LT-0679) for specific information.

17.2 Contact Rating

The Model 305 relay contacts are rated for 1 Amp at 30 VDC (allows .35 power factor). Connect auxiliary power to the Relay Output 1 common terminal by installing the gray harness wire to terminal 7. Current draw for all connected devices must not exceed the panel maximum current rating.

17.3 Output Harness Wiring

The Output Harness is pre-installed on the 6-pin header labeled J2. Output 2 uses the top three prongs, and Output 1 uses the bottom three prongs. Outputs 1 and 2 are pre-wired to the 866 NAC modules located within the XR2500F enclosure. For reference, the wire harness and contact locations are shown below:

Contact

Color

Output 1 normally closed

Violet

Output 1 common

Gray

Output 1 normally open

Orange

Output 2 normally closed

Blue

Output 2 common

White

Output 2 normally open

Yellow

Digital Monitoring Products

XR2500F Installation Guide

24

Image 32
Contents Installation Guide Model XR2500F Command Processor Installation Guide Secondary Power Supply Fire Command CenterIntroduction MountingAccessory Devices Battery InformationPowered Zones for 2-Wire Smoke Detectors J22 LX-Bus Expansion ConnectorJ1 Ethernet Connector Reset and Tamper HeadersListed Compliance Specifications Universal UL Burglary SpecificationsHoldup Alarm Units Digital Burglar Alarm Communicator System Units ANSI/ ULPolice Station Connected and Local Burglar Alarm Units Access Control System UnitsCalifornia State Fire Marshal Specifications New York City MEA SpecificationsWiring Diagrams Household Fire Warning System Units ANSI/UL 985, NfpaThis page intentionally left blank Introduction LX-Bus OutputsRelays Zone ReferenceMounting Wiring Diagram Use MarkingTransformers and AC Power Connection AC Connection16 VAC Transformer Earth Ground GNDDescription Secondary Power SupplyBattery Connection to XR2500F Command Processor panel Bell Silence/Bell Trouble Two 866 NAC ModulesConnection Installing the 481 Card LX-Bus OperationXR2500F On-board LX-Bus LX-Bus 481 Zone Expansion Interface Card893A Dual Phone Line Module Notification FCC RegistrationFire Command Center Remote Fire Command CenterOutput Expansion ExpansionZone Expansion Accessory Devices Lightning ProtectionAccessory Devices Connecting LX-Bus and Keypad Bus Devices Mounting Keypads and Zone Expansion ModulesBattery Information 11.7 XR2500F Standby Battery Calculations Copy Sub-Totals to nextThis page only Standby Battery Selection Bell Output Keypad BusPowered Zones for 2-Wire Smoke Detectors Smoke and Glassbreak Detector OutputTerminals 11 Current RatingCompatible 2-Wire Smoke Detector Chart DS250HDKeyswitch Arming Zone Protection ZonesTerminals Operational ParametersContact Rating Output Harness WiringDry Contact Relay Outputs Model 300 Harness Wiring J11 Annunciator OutputsJ23 6-Pin Header Model 860 Relay ModuleJ22 LX-Bus Expansion Connector J21 Serial ConnectorSerial Connector LEDs LX-Bus Interface CardsJ1 Ethernet Connector Reset and Tamper Headers23.1 J16 Reset Header Ethernet LEDsListed Compliance Specifications Universal UL Burglary SpecificationsHousehold Burglar-Alarm System Units ANSI/UL Area InformationProprietary Dialer Dact Central StationStandard or Encrypted Line Security Model 463G Cell Only, Standard or Encrypted Line SecurityPath 1 programming Path 2 programming Path 3 programming Police Station Connected and Local Burglar Alarm Units Holdup Alarm UnitsDigital Burglar Alarm Communicator System Units ANSI/ UL Bell Automatic Bell TestPath 1 programming Path 2 programming Path 3 programming Access Control System Units MercantilePanel Designation Compatible DevicesUniversal Fire Alarm Specifications Power Supply Power Fail DelayLocal Protective Signaling Systems Remote Station Protective Signaling SystemsGround Fault Household Fire Warning System Units ANSI/UL 985, NfpaNotification Appliances Cross ZoningCalifornia State Fire Marshal Specifications New York City MEA SpecificationsDigital Dialer and Network Communication Communication ProgrammingWiring Diagrams Prewired 866 Modules with NAC ExtenderWiring Diagrams Alarm Bell PWR Bell Out + Bell Trouble DSM-12/24 Module 39.5 867 Class B Style W Notification Appliance Circuit To initiating zoneTo initiating zone DMP Model Dual Style D Zone Module Installation Command Processor Panel Remote Station Reversing Relay ConnectionSecond LX-Bus with Auxiliary Power Supply XR2500F 481 Command Processor PanelLX-Bus Module Connection Powered Burglary Devices Model 860 Relay Module ConnectionRevisions to This Document Ver Section Number and Heading Quick Explanation of ChangesThis page intentionally left blank Operating Instructions Model XR2500F Panels Mounting Instructions Listings and Approvals

XR2500F specifications

The DMP Electronics XR2500F is an advanced and versatile electronic device designed to cater to a wide range of applications including industrial automation, robotics, and smart home technologies. Known for its robust performance and reliable functionalities, the XR2500F stands out as a leading option in the market.

One of the main features of the XR2500F is its powerful processing unit, which ensures efficient handling of complex tasks and data processing. With a clock speed of up to 2.5 GHz, the device is capable of multitasking, enabling users to run multiple applications simultaneously without compromising performance. This makes the XR2500F an ideal choice for applications that require real-time data processing and analysis.

The XR2500F is equipped with an extensive array of connectivity options, including Wi-Fi, Bluetooth, and Ethernet capabilities. This allows for seamless integration with various devices and networks. The wireless options facilitate easy communication with cloud services and other IoT devices, making it suitable for smart home automation systems, where synchronization and control are critical.

In terms of memory, the XR2500F offers significant storage capacity, with options that can accommodate up to 64GB of RAM and 512GB of flash storage. This ample memory ensures that users can store large amounts of data and run memory-intensive applications without experiencing slowdowns. Additionally, the device supports expandable memory options, allowing for future upgrades to meet growing demands.

The XR2500F also incorporates advanced security technologies to protect sensitive data. Features like end-to-end encryption and secure boot processes safeguard against unauthorized access and data breaches. This is particularly important in industrial settings where data integrity is critical for operational safety.

Another remarkable characteristic of the XR2500F is its energy efficiency. Designed with the latest power management technologies, the device minimizes energy consumption while maximizing performance. This not only reduces operational costs but also aligns with green technology initiatives.

Overall, the DMP Electronics XR2500F is a high-performance electronic device that combines powerful processing, extensive connectivity, robust memory, enhanced security, and energy efficiency. Its versatility and reliability make it a preferred choice for professionals seeking innovative solutions in automation and control systems.