Installation
J1 Ethernet Connector
22.1 Description
The J1 Ethernet Connector is available to connect directly to an Ethernet network using a standard patch cable. The maximum line impedance is 100 Ohms.
Link LED Activity LED
J1
Ethernet
Figure 15: J1 Header and LEDs
22.2 Ethernet LEDs
The two LEDs, located to the left of J1 Ethernet Connector, indicate network operation. The top, Activity LED flashes green to indicate the network traffic is good. The bottom, Link LED flashes yellow to indicate messages are being sent and received.
Reset and Tamper Headers
23.1 J16 Reset Header
The reset header is located just above the terminal strip on the right side of the circuit board and is used to reset the XR2500F microprocessor. To reset the panel when first installing the system, install the reset jumper before applying power to the panel. After connecting the AC and battery, remove the reset jumper.
To reset the panel while the system is operational, for example, prior to reprogramming, install the reset jumper without powering down the system. Remove the reset jumper after one or two seconds.
After resetting the panel, begin programming within 30 minutes. If you wait longer than 30 minutes, you must reset the panel again.
J3 |
| J4 |
|
|
Phone Line |
|
|
| |
|
| Tamper |
|
|
| Link LED |
|
| |
Activity LED |
| Momentarily place the Reset | ||
|
|
|
| |
|
| J1 |
| jumper over both of the J16 |
|
| Ethernet |
| pins to reset the panel. |
|
| J21 |
| |
|
|
|
| |
Power | R | J23 |
|
|
LED |
|
| ||
L | J22 |
|
| |
|
|
| ||
| X |
|
| |
| OVC |
| ||
|
|
| ||
|
| Output 1 | Output 2 |
J6
Interface
Card
Expansion
Connector
Battery
Start
J10
J8
PROG
K6
J2 | Out2 |
| |
| Out1 |
J11
K7 | 3 |
| 4 |
| 5 |
| 6 |
Outputs
J16
Reset
AC | AC | +B | GND | Z2 | Z3 GND Z4 | Z5 | GND | Z6 Z7 | GND Z8 | Z9+ Z9– Z10+ Z10– | ||||||||||||||||
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 22 | 23 | 24 | 25 | 26 | 27 | 28 |
Figure 16: XR2500F Panel Showing the Reset Jumper
23.2 J4 Tamper Header
The J4 header is for use with the optional DMP 306 Tamper Harness. The harness connects to one or more tamper switches mounted inside the panel enclosure to supervise against unauthorized enclosure opening or removal. Refer to the wiring diagram on the enclosure door for correct tamper switch wiring.
How the Tamper Works
If the enclosure is opened or removed while one or more of the system areas are armed, a panel tamper alarm is indicated. If all areas are disarmed, a panel tamper trouble is indicated.
XR2500F Installation Guide | Digital Monitoring Products |
27