C. Optional Accessories
Optional fan and remote control kits require that
Fan Installation
To provide best airflow, we recommend positioning fan on the left side (as viewed from appliance interior side - see Figure 7.2). NOTE: It is recommended fan be in- stalled prior to gas line installation.
Wall Switch
Position the wall switch in the desired position on a wall. Run a maximum of 25 feet (7.8 m) or less length of 18 A.W.G. minimum wire and connect it to the appliance ON/ OFF switch pigtails.
APPLIANCE |
|
INTERIOR |
|
SIDE |
|
FAN | |
| DRIP |
| TRAY |
Figure 7.2 | Fan location |
FAN SPEED |
|
|
CONTROL |
| WIRE LEAD |
(RHEOSTAT) | 6 FT. | |
| 1 MALE END | |
| APPROX. | 1 FEMALE END |
TEMPERATURE
SENSOR SWITCH
WIRE LEAD
2 FEMALE ENDS
6 FT.
APPROX.
FAN KIT
PLUG AND WIRE
ASSEMBLY
DETAIL A
JUNCTION BOX
SEE DETAIL A
NOTE: If any of the original wire as supplied with the appliance must be replaced, it must be replaced with the type 105oC rated wire.
Figure 7.1 Fan Wiring Diagram
18 | Heat & Glo LifeStyle Collection • |