Hearth and Home Technologies II-B Appliance Setup, Remove Shipping Materials, Clean the Appliance

Page 24

9 Appliance Setup

A. Remove Shipping Materials

Remove shipping materials from inside or underneath the firebox.

Placing Lava Rock

Place lava rock on refractory support pan. Cover entire support pan surface (see Figure 9.1).

B. Clean the Appliance

Clean/vacuum any sawdust that may have accumulated inside the firebox or underneath in the control cavity.

C. Accessories

Install approved accessories per instructions included with accessories. See Service Parts List for appropriate acces- sories. Refer to Section 13.

WARNING

Shock or fire risk.

Use ONLY optional accessories approved for this appliance.

Using non-listed accessories voids warranty.

Using non-listed accessories may result in a safety hazard.

Only Hearth & Home Technologies approved

accessories may be used safely.

D. Lava Rock and Ember Placement

WARNING

Explosion Risk.

Follow ember placement instructions in manual.

Do NOT place embers directly over burner ports.

Replace ember material annually.

Improperly placed embers interferes with proper burner operation.

Figure 9.1 Placement of Lava Rock

Placing the Ember Material

Ember material is shipped with this gas appliance. To place the ember material:

Embers CANNOT be placed directly over ports.

When placing Glowing Embers® onto the burner care should be taken so that the ports are not covered. Place the dime-size ember pieces just in front of the port trail, but not on or in between the ports (see Figure 9.2). Fail- ure to follow this procedure will likely cause lighting and sooting problems.

Figure 9.2 Placement of Ember Materials

Save the remaining ember materials for use during appliance servicing. The embers provided should be enough for 3 to 5 applications.

24

Heat & Glo LifeStyle Collection • Twilight-II-B2108-900 Rev. G • 8/07

Image 24
Contents Model Twilight-II-B Congratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsDesign and Installation Considerations Getting StartedTools and Supplies Needed Inspect Appliance and ComponentsFraming and Clearances Selecting Appliance LocationClearances Fire Risk Odor RiskMantel Projections Indoor only CeilingTermination Locations Appliance Opening Minimum ClearancesRemoving Non-combustible Facing Material Assembly Appliance PreparationSecuring and Leveling the Appliance Placing Metal Hearth StripPlacing and Securing Appliance Placing Flashing and SheathingApply housewrap or building paper Risk of FireInstalling Non-combustible Facing Material Outdoor Side 19 Attaching Non-combustible Facing MaterialGas Information Fuel Conversions Gas ConnectionGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Recommendation for Wire Connecting to the ApplianceElectrical Information Optional Accessories Fan locationIntellifire Ignition System Wiring Optional Accessories RequirementsJunction Box Installation Wall Switch Installation for Fan OptionalFinishing Mantel ProjectionsFacing Material Risk of Fire Detail Appliance Setup Clean the ApplianceAccessories Lava Rock and Ember PlacementLog Set Assembly LOGS-TWI Positioning the LogsInch Sharp Notch Smooth Cutout Sharp NotchGlass Assembly Shutter SettingsRemoving Glass Assembly Replacing Glass AssemblyOperating Instructions Before Lighting ApplianceLighting Appliance Intellifire IgnitionFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Intellifire Ignition SystemSympton Possible Cause Corrective Action Symptom Possible Cause Corrective Action Maintenance Tasks Maintaining and Servicing ApplianceInspect Maintenance Tasks Recommend addition of screen if one is not presentAppliance Dimension Diagram Reference MaterialsService Parts Log Set AssemblyService Parts List IPI Valve Assembly Limited Lifetime Warranty Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsContact Information Do not Discard this Manual