Hearth and Home Technologies II-B owner manual Inspect Maintenance Tasks

Page 34

Inspect

 

Maintenance Tasks

Doors, Surrounds

1. Assess condition of screen and replace as necessary.

and Fronts

Recommend addition of screen if one is not present.

 

2.

Inspect for scratches, dents or other damage and repair as necessary.

 

 

 

 

3.

Verify no obstructions to airflow through the louvers.

 

 

 

 

4.

Verify maintenance of proper clearance to combustible household objects.

Gasket Seal, Glass

1. Inspect gasket seal and its condition.

Assembly and Glass

 

 

2.

Inspect glass panels for scratches and nicks that can lead to breakage when exposed to heat.

 

 

 

 

 

3.

Confirm there is no damage to glass or glass frame. Replace as necessary.

 

 

 

 

4.

Verify that latches engage properly, clip studs are not stripped, and glass attachment components are intact

 

and operating properly. Replace as necessary.

 

5.

Clean glass. Replace glass assembly if severely coated with silicate deposits that cannot be removed.

Valve Compartment

1.

Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these areas. Screw

and Firebox Top

tips that have penetrated the sheet metal are sharp and should be avoided.

 

2.

Remove any foreign objects.

 

3.

Verify unobstructed air circulation.

Logs

1.

Inspect for broken, damaged, or missing logs. Replace as necessary.

 

 

 

 

2.

Verify correct log placement and no flame impingement causing sooting. Correct as necessary.

Firebox

1.

Inspect for paint condition, warpage, corrosion or perforation. Sand and repaint as necessary.

 

2.

Replace appliance if firebox has been perforated.

 

 

 

Burner Ignition and

1.

Verify burner is properly secured and aligned with pilot or igniter.

Operation

 

 

2.

Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if necessary.

 

 

3.

Replace ember materials with new dime-size and shape pieces. Do not block ports or obstruct lighting paths.

 

4.

Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.

 

 

 

 

5.

Inspect for lifting or other flame problems.

 

 

 

 

6.

Verify air shutter is clear of dust and debris.

 

 

 

 

7.

Inspect orifice for soot, dirt or corrosion.

 

8.

Verify manifold and inlet pressures. Adjust regulator as required.

 

 

 

 

9.

Inspect pilot flame strength. Clean or replace orifice as necessary.

 

 

 

10. Inspect thermocouple/thermopile or IPI sensor rod for soot, corrosion and deterioration. Clean with emery

 

cloth or replace as required.

 

11. Verify millivolt output. Replace as necessary.

 

 

Venting

1. Inspect venting for blockage or obstruction such as bird nests, leaves, etc.

 

2.

Confirm that termination cap remains clear and unobstructed by plants, etc.

 

3.

Verify that termination cap clearance to subsequent construction (building additions, decks, fences or

 

sheds) has been maintained.

 

4.

Inspect for corrosion or separation.

 

 

 

 

5.

Verify weather stripping, sealing and flashing remains intact.

 

 

 

 

6.

Inspect draft shield to verify it is not bent, damaged or missing.

 

 

Remote controls

1. Verify operation of remote.

 

2.

Replace batteries in remote transmitters and battery-powered receivers.

 

3.

Verify batteries have been removed from battery back-up IPI systems to prevent premature battery failure

 

or leaking.

34

Heat & Glo LifeStyle Collection • Twilight-II-B2108-900 Rev. G • 8/07

Image 34
Contents Model Twilight-II-B Congratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsTools and Supplies Needed Design and Installation ConsiderationsGetting Started Inspect Appliance and ComponentsFraming and Clearances Selecting Appliance LocationClearances Fire Risk Odor RiskMantel Projections Indoor only CeilingTermination Locations Appliance Opening Minimum ClearancesSecuring and Leveling the Appliance Removing Non-combustible Facing Material AssemblyAppliance Preparation Placing Metal Hearth StripPlacing and Securing Appliance Placing Flashing and SheathingApply housewrap or building paper Risk of FireInstalling Non-combustible Facing Material Outdoor Side 19 Attaching Non-combustible Facing MaterialGas Pressures Gas InformationFuel Conversions Gas Connection Pressure Natural Gas PropaneHigh Altitude Installations Connecting to the Appliance Recommendation for WireElectrical Information Optional Accessories Fan locationIntellifire Ignition System Wiring Optional Accessories RequirementsJunction Box Installation Wall Switch Installation for Fan OptionalMantel Projections FinishingFacing Material Risk of Fire Detail Accessories Appliance SetupClean the Appliance Lava Rock and Ember PlacementPositioning the Logs Log Set Assembly LOGS-TWIInch Sharp Notch Smooth Cutout Sharp NotchRemoving Glass Assembly Glass AssemblyShutter Settings Replacing Glass AssemblyOperating Instructions Before Lighting ApplianceLighting Appliance Intellifire IgnitionInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Intellifire Ignition System TroubleshootingSympton Possible Cause Corrective Action Symptom Possible Cause Corrective Action Maintenance Tasks Maintaining and Servicing ApplianceInspect Maintenance Tasks Recommend addition of screen if one is not presentAppliance Dimension Diagram Reference MaterialsService Parts Log Set AssemblyService Parts List IPI Valve Assembly Limited Lifetime Warranty Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsContact Information Do not Discard this Manual