D. Intellifire Ignition System Wiring
This appliance requires a 110 VAC supply to the appliance junction box for operation. When using the transformer, the junction box must have uninterrupted 120V. A wiring diagram is shown in Figure 7.3.
This appliance is equipped with an Intellifire control valve which operates on a 3 volt system.
This appliance is supplied with a battery pack and a 3 volt AC transformer, which requires the installation of the supplied junction box. It is highly recommended that the junction box be installed at this time to avoid reconstruction.
The battery pack requires two D cell batteries (not included).
NOTE: Batteries cannot be placed in the battery pack while using the 3 volt AC transformer. The transformer must be unplugged if the battery pack is used or battery life will be reduced.
CAUTION
Battery polarity must be correct or module damage will occur.
Optional Accessories Requirements
Wiring for optional accessories should be done now to avoid reconstruction.
IGNITION MODULE | ||
3 VAC | ||
3V TRANSFORMER | ||
|
ON/OFF
WALL
SWITCH
FLAME SPARKER/
SENSOR
IGNITION MODULE (3V)
VALVE | LOW VOLTAGE |
| SEE NOTE 1 |
| GROUND REMOTE |
NEUTRAL | CONTROL HOT |
| WHITE WIRE |
| CAN BE |
| PLUGGED |
| INTO ANY |
BLACK WIRE CAN BE | OF |
PLUGGED INTO ANY OF | LOCATIONS |
#1 - #5 LOCATIONS | ON THE |
ON THE HOT SIDE | NEUTRAL SIDE TRANSFORMER |
| 3 VAC |
| PLUG IN |
I
S
WHT
ORG
GROUND TO
FIREPLACE
CHASSIS
BRN | BRN | * |
|
ORG
PIGGYBACK
ON/OFF SWITCH
VALVE
INTERMITTENT
PILOT
IGNITOR
GRN
NOTE: 1. Ignition module, valve, pilot, and wall switch operate on 3 volts.
Uninterrupted 120 VAC is required at junction box unless equipped with battery
Figure 7.3 Intellifire Pilot Ignition (IPI) Wiring Diagram
Heat & Glo LifeStyle Collection • | 19 |