Hearth and Home Technologies C-40 warranty Electrical Access and Wiring Diagram, Suggestions

Page 13

Suggestions:

1.Insulate chase.

2.Finish chase walls with dry wall 5/8 in. (16mm) Type X face tape.

3.All dimensions are to finished walls and ceilings.

Figure 13.1 Sheetrocked Chase

WARNING

Fire Risk

Comply with all minimum clearances speci- fied.

A minimum 1/2 in. (13mm) air clearance must be maintained at the back and 1 in. (25mm) to the sides of the fireplace assembly.

Chimney sections at any level require a 2 in. (51mm) minimum air space clearance between the framing and chimney section.

WARNING

Fire Risk

Do not apply combustible finishing materials over any part of the front of this fireplace.

The metal fireplace face may only be covered with noncombustible materials such as ceramic tile, brick, or stone.

Do not cover or block any cooling air slots.

The decorative fascia must be removable for future serviceability of the Automatic Combustion Control.

WARNING

Fire Risk

Maintain clearances.

Use only non-combustible material below standoffs, material such as cement board is acceptable.

Framing or finishing material used on the front of, or in front of, the appliance closer than the minimums listed, must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc.).

D. Electrical Access and Wiring Diagram

NOTE: The manual override switch, rheostat speed control and cover plate are supplied. You will need to supply: 14-3 wire with ground; 14-2 wire with ground; standard wall mount junction box; wire nuts.

1.

Remove junction box cover plate on the

 

bottom right side of the fireplace.

2.

Thread the 14-3 with ground wire through

 

the opening with the strain relief on the cover

 

plate.

3.

Match colors to wire harness, (red to red,

 

14-3 w/ground

Match colors to wire

WHITE

harness (red to red,

 

white to white, etc) and

 

secure with a wire nut

 

Standard wall mount with Junction Box

14-2 w/ground

WIRE NUT

WHITE

GREEN

white to white, etc) and secure with wire

nuts.

NOTE: Wiring for fans must be done before framed enclosure is completed. If using a Heat Zone kit, it also must be installed before enclosure is complete.

Power to the Fireplace

 

Snap Disc

RED

bypass switch

 

 

BLACK

Figure 13.2 Fan Wiring Diagram

BLACK

Incoming Power

(110V)

November 11, 2008

Heatilator • Constitution EPA Fireplace • 480-1091C

Page 13

Image 13
Contents Hot glass will cause burns Installation and OperationFire Risk Serial No Model Name Test Lab Report No Manufactured Date Listing Label Information/LocationTable of Contents Appliance Certification Listing and Code ApprovalsMobile Home Approved BTU & Efficiency Specifications Glass SpecificationsGetting Started Design and Installation ConsiderationsNegative Pressure Asphyxiation RiskNovember 11 Heatilator Constitution EPA Fireplace 480-1091C Typical Fireplace System Typical Fireplace SystemInspect Fireplace and Components Tools and Supplies NeededFire Risk Explosion Risk Selecting Fireplace Location Framing and ClearancesModel Constitution Clearances to Combustible Materials ClearancesMinimum Clearances to Combustibles Frame the FireplaceOptional Framing Construction / Reduced Mantel Height Non-Combustible MaterialsSuggestions Electrical Access and Wiring DiagramMaterials Construct the ChaseInstall the Outside Air Kit Installation of FireplaceRisk of Smoke Spillage Fire Risk Asphyxiation RiskHandle Left Closed Handle Right OpenPosition the Fireplace Secure the FireplacePlace the Protective Metal Hearth Strips Position the Protective Metal Hearth Strips Level the FireplaceChimney Assembly Chimney Termination Requirements Chimney RequirementsExample Using Offsets/ReturnsAssemble the Chimney Sections Installing CAK4A and Flex PipeAssembling Chimney Sections for the SL- 300 Series Installing Flex Pipe Install the Ceiling FirestopsDouble-check the Chimney Assembly Install the Attic Insulation ShieldSecure the Chimney Chimney Termination 2-10-3 Rule Complete the EnclosureChimney Termination Requirements See Figures 25.1 Slanted RoofsInstall the Chimney Air Kit required in Canada Install the Roof FlashingMark the Exit Point of the Roof Cut Out the Hole in the RoofConsult local codes for framing details SL-300 Series Ceiling/Roof ThimbleChase Top Install the Termination CapChase Top Framing ‑1/2 in mm below the chase top. See Figure Fan Replacement AccessoriesFan Replacement Instructions Shock RiskDoor and Door Gasket Baffle Removal and InstallationMinimum Clearance to Combustibles Heat Zone Kit20 ft 3 6m 10 ft 1 3m No cut needed Run Length Cut Pipe Ft 6-12m4 wall Timer Assembly Timer Assembly ReplacementRemove & Replace Timer Timer Override Lever Manual Timer OverrideHearth Extension FinishingCalculating Alternate Floor Protection Material Positioning the Protective Metal Hearth Strips Model # Constitution 1041 508Fascia Outer Tile or Marble Combustible Can Flange Floor Position the Hearth Extension Finishing Material Risk of Fire Non-Combustible Facing Material InstallationMantel Mantel SpecificationsOperating Instructions Symptoms of Over-FiringOver-Firing Your Appliance General InformationKeep open during use Outside AirFirescreen Clear Space Near the FireplaceGlass Doors Fan OperationWood Fuel Hardwood vs. Softwood Moisture contentSeasoning Starting a Fire Storing WoodFire Risk Incorrect Positions Correct Baffle & Blanket PlacementAutomatic Combustion Control ACC Burning ProcessBurn Rates Burning GuidelinesOpacity Burn Rate BTU / Hr Slide Air ControlChimney Fire Fire SafetyUnderstanding Vent Problems TroubleshootingDraft Problems Factory-built Fireplaces Troubleshooting Diagnostic Question Possible Causes of Condition Solutions Diagnostics and Problem SolvingDon’t get enough/any heat. What can I do about it? General Maintenance Maintenance and Servicing the FireplaceClean Creosote Chimney CleaningGlass Cleaning Glass ReplacementDisposal of Ashes Fire Risk Injury RiskFirebrick Replacement Maintenance Task List Care and Cleaning of Plated SurfacesInspect Maintenance Tasks Date of Service Performed By Description of Service Service & Maintenance LogReference Materials Fireplace DimensionsConstitution Chimney Components 15-3/4 NorthStar Fireplace Diagram Parts DiagramConstitution FP Service PartsBeginning Manufacturing Date Ending Manufacturing DateDescription Comments Serial Number Date SL1This page intentionally left blank CONDITIONS, Exclusions & Limitation of Liability Warranty Policy Hearth & Home Technologies Limited WarrantyHearth & Home Technologies Limited Warranty Cont’d Do not Discard this Manual Contact Information

C-40 specifications

Hearth and Home Technologies (HHT) has long been known for its commitment to innovation and quality in the heating and home comfort industry. One of their standout offerings is the C-40, a versatile and efficient gas fireplace that embodies the brand’s dedication to modern aesthetics and advanced technology. This fireplace is designed to not only provide warmth but also enhance the ambiance of any living space.

The C-40 features a sleek, contemporary design that can seamlessly fit into various interior styles. Its clean lines and minimalist frame allow it to serve as a stylish focal point in a room, while offering the functionality and performance that homeowners expect from a high-quality gas fireplace. The unit is available in various configurations, including built-in and wall-mounted options, allowing for flexibility in installation and design.

One of the most notable features of the C-40 is its impressive heat output. With the ability to deliver efficient and evenly distributed warmth, this gas fireplace can effectively heat spaces of various sizes, making it an excellent choice for both small and large rooms. The adjustable flame height feature further enhances the user experience, allowing homeowners to customize their heating preference and create the perfect atmosphere for any occasion.

The C-40 is equipped with cutting-edge technologies, including electronic ignition and a remote control system, making it convenient and easy to use. The electronic ignition ensures quick and reliable startup, while the remote control allows for effortless temperature and flame adjustment from anywhere in the room. This added convenience is a significant benefit for those who value comfort and ease of operation.

Additionally, the C-40 incorporates advanced safety features, such as an automatic shut-off and a secure glass front, providing peace of mind for families. The glass front not only enhances safety but also serves to display the mesmerizing flames beautifully, allowing everyone to enjoy its warmth and glow.

In summary, Hearth and Home Technologies’ C-40 is a prime example of combining stylish design with modern technology and efficiency. Its exceptional heat output, customizable features, and advanced safety measures make it a standout choice for homeowners looking to enhance their living spaces with a dependable gas fireplace. Whether for cozy family gatherings or quiet evenings at home, the C-40 offers both aesthetic appeal and functional excellence, ensuring it remains a popular choice in contemporary home design.