Hearth and Home Technologies C-40 warranty Baffle Removal and Installation, Door and Door Gasket

Page 31

B. Baffle Removal and Installation

1.Remove all ash from firebox, and extinguish all hot embers before disposal into a metal container.

2.Remove the baffle protection channel by turning it down and pulling it out of the firebox. See Figure 31.1.

Figure 31.3 Removing Baffle (shown without ceramic blanket)

Figure 31.1 Removing Baffle Protection Channel

3.Remove ceramic blanket from above the baffle.

4.With a 3/16 in. Allen wrench, remove the front manifold tube retainer bolt on the air channel under the end of the front tube. See Figure 31.2.

C. Door and Door Gasket

Periodically check the door gasket for proper seal. As the gasket compresses or “seats” during use, it may become necessary to adjust or tighten the door latch.

To Adjust or Tighten Door Latch

Remove spacing washers shown in Figure 31.4. At least one spacing washer and the black washer must be left in place.

OR

Replace the gasket material. Wear or damage to the gasket material can cause air leakage into the firebox resulting in overfiring and loss of efficiency.

A replacement gasket is available from your dealer.

Figure 31.2 Removing Manifold Tube

NOTE: Soak the bolt with penetrating oil for at least 15 minutes before trying to remove it.

5.To remove manifold tube, slide the tube to one side until one end is out of its hole. Then, while lifting that end of the fiber board baffle, pull tube up over the air channel and out of hole at the other end. It is only necessary to remove the first tube in order to remove the baffle.

6.Slide fiber board baffle forward to front of fireplace and straight out through door. See Figure 31.3.

7.To install the fiber board baffle, repeat steps 2 through 4 in reverse. Be sure the fiber board baffle and ceramic blanket are pushed back fully and the blanket is down and flat.

Latch Cam

 

Door Cross Section

(example)

Locknut

 

 

Handle

 

Teflon Washer

Spacing Washers

DO NOT REMOVE

 

Square Key

Figure 31.4 Door Handle Assembly

November 11, 2008

Heatilator • Constitution EPA Fireplace • 480-1091C

Page 31

Image 31
Contents Hot glass will cause burns Installation and OperationFire Risk Serial No Model Name Test Lab Report No Manufactured Date Listing Label Information/LocationTable of Contents Appliance Certification Listing and Code ApprovalsMobile Home Approved BTU & Efficiency Specifications Glass SpecificationsAsphyxiation Risk Design and Installation ConsiderationsGetting Started Negative PressureNovember 11 Heatilator Constitution EPA Fireplace 480-1091C Typical Fireplace System Typical Fireplace SystemInspect Fireplace and Components Tools and Supplies NeededFire Risk Explosion Risk Selecting Fireplace Location Framing and ClearancesModel Constitution Clearances to Combustible Materials ClearancesNon-Combustible Materials Frame the FireplaceMinimum Clearances to Combustibles Optional Framing Construction / Reduced Mantel HeightSuggestions Electrical Access and Wiring DiagramMaterials Construct the ChaseInstall the Outside Air Kit Installation of FireplaceHandle Right Open Fire Risk Asphyxiation RiskRisk of Smoke Spillage Handle Left ClosedPosition the Fireplace Secure the FireplacePlace the Protective Metal Hearth Strips Position the Protective Metal Hearth Strips Level the FireplaceChimney Assembly Chimney Termination Requirements Chimney RequirementsExample Using Offsets/ReturnsAssemble the Chimney Sections Installing CAK4A and Flex PipeAssembling Chimney Sections for the SL- 300 Series Installing Flex Pipe Install the Ceiling FirestopsDouble-check the Chimney Assembly Install the Attic Insulation ShieldSecure the Chimney Slanted Roofs Complete the EnclosureChimney Termination 2-10-3 Rule Chimney Termination Requirements See Figures 25.1Cut Out the Hole in the Roof Install the Roof FlashingInstall the Chimney Air Kit required in Canada Mark the Exit Point of the RoofConsult local codes for framing details SL-300 Series Ceiling/Roof ThimbleChase Top Install the Termination CapChase Top Framing ‑1/2 in mm below the chase top. See Figure Shock Risk AccessoriesFan Replacement Fan Replacement InstructionsDoor and Door Gasket Baffle Removal and InstallationMinimum Clearance to Combustibles Heat Zone Kit20 ft 3 6m 10 ft 1 3m No cut needed Run Length Cut Pipe Ft 6-12m4 wall Timer Assembly Timer Assembly ReplacementRemove & Replace Timer Timer Override Lever Manual Timer OverrideHearth Extension FinishingCalculating Alternate Floor Protection Material Positioning the Protective Metal Hearth Strips Model # Constitution 1041 508Fascia Outer Tile or Marble Combustible Can Flange Floor Position the Hearth Extension Finishing Material Risk of Fire Non-Combustible Facing Material InstallationMantel Mantel SpecificationsGeneral Information Symptoms of Over-FiringOperating Instructions Over-Firing Your ApplianceKeep open during use Outside AirFan Operation Clear Space Near the FireplaceFirescreen Glass DoorsWood Fuel Hardwood vs. Softwood Moisture contentSeasoning Starting a Fire Storing WoodFire Risk Incorrect Positions Correct Baffle & Blanket PlacementAutomatic Combustion Control ACC Burning ProcessBurn Rate BTU / Hr Slide Air Control Burning GuidelinesBurn Rates OpacityChimney Fire Fire SafetyUnderstanding Vent Problems TroubleshootingDraft Problems Factory-built Fireplaces Troubleshooting Diagnostic Question Possible Causes of Condition Solutions Diagnostics and Problem SolvingDon’t get enough/any heat. What can I do about it? Creosote Chimney Cleaning Maintenance and Servicing the FireplaceGeneral Maintenance CleanFire Risk Injury Risk Glass ReplacementGlass Cleaning Disposal of AshesFirebrick Replacement Maintenance Task List Care and Cleaning of Plated SurfacesInspect Maintenance Tasks Date of Service Performed By Description of Service Service & Maintenance LogReference Materials Fireplace DimensionsConstitution Chimney Components 15-3/4 NorthStar Fireplace Diagram Parts DiagramEnding Manufacturing Date Service PartsConstitution FP Beginning Manufacturing DateDescription Comments Serial Number Date SL1This page intentionally left blank CONDITIONS, Exclusions & Limitation of Liability Warranty Policy Hearth & Home Technologies Limited WarrantyHearth & Home Technologies Limited Warranty Cont’d Do not Discard this Manual Contact Information

C-40 specifications

Hearth and Home Technologies (HHT) has long been known for its commitment to innovation and quality in the heating and home comfort industry. One of their standout offerings is the C-40, a versatile and efficient gas fireplace that embodies the brand’s dedication to modern aesthetics and advanced technology. This fireplace is designed to not only provide warmth but also enhance the ambiance of any living space.

The C-40 features a sleek, contemporary design that can seamlessly fit into various interior styles. Its clean lines and minimalist frame allow it to serve as a stylish focal point in a room, while offering the functionality and performance that homeowners expect from a high-quality gas fireplace. The unit is available in various configurations, including built-in and wall-mounted options, allowing for flexibility in installation and design.

One of the most notable features of the C-40 is its impressive heat output. With the ability to deliver efficient and evenly distributed warmth, this gas fireplace can effectively heat spaces of various sizes, making it an excellent choice for both small and large rooms. The adjustable flame height feature further enhances the user experience, allowing homeowners to customize their heating preference and create the perfect atmosphere for any occasion.

The C-40 is equipped with cutting-edge technologies, including electronic ignition and a remote control system, making it convenient and easy to use. The electronic ignition ensures quick and reliable startup, while the remote control allows for effortless temperature and flame adjustment from anywhere in the room. This added convenience is a significant benefit for those who value comfort and ease of operation.

Additionally, the C-40 incorporates advanced safety features, such as an automatic shut-off and a secure glass front, providing peace of mind for families. The glass front not only enhances safety but also serves to display the mesmerizing flames beautifully, allowing everyone to enjoy its warmth and glow.

In summary, Hearth and Home Technologies’ C-40 is a prime example of combining stylish design with modern technology and efficiency. Its exceptional heat output, customizable features, and advanced safety measures make it a standout choice for homeowners looking to enhance their living spaces with a dependable gas fireplace. Whether for cozy family gatherings or quiet evenings at home, the C-40 offers both aesthetic appeal and functional excellence, ensuring it remains a popular choice in contemporary home design.