Hearth and Home Technologies C-40 warranty Install the Ceiling Firestops, Installing Flex Pipe

Page 23

Wire Ties

4" Flex

Wire Ties

Figure 23.1 Installing Flex Pipe

F. Install the Ceiling Firestops

Mark and cut an opening in the ceiling for the ceiling firestop being used. See Figure 23.2.

Frame the opening with the same size lumber used in the ceiling joists.

Install the firestop spacer.

These firestop spacers are designed to provide the minimum 2 in. (51 mm) air space required around the chimney. In all situations, the firestop spacers are to be nailed to the ceiling joists from the bottom or fireplace side, EXCEPT when the space above is an insulated ceiling or attic space. In this situation, the firestop spacer must be nailed from the top side to prevent loose insula- tion from falling into the required 2 in. (51 mm) air space around the chimney.

NOTE: See Figures 24.1 and 24.2 on page 24.

CAUTION

Ceiling firestops must be used at ceiling/floor.

Chase construction requires ceiling firestops at each floor or every 10 ft (3.05 m) of clear space.

Use same dimensional lumber as joists.

Ceiling firestop slows spread of fire and reduces cold air infiltration.

Note: The ceiling firestop MUST be nailed to the bottom of the ceiling joists EXCEPT when the space above is uninsulated and the attic insulation shield is not being used (see Figure 23.2). When the attic insulation shield is used the ceiling firestop may be above or below the joist of an insulated ceiling.

ROOM ABOVE (non-insulated ceiling)

B

A

Ceilng firestop

 

attached to bottom

 

of framing

2 in. (51mm)

 

clearance

ATTIC ABOVE (insulated ceiling)

Ceiling firestop

When attic insulation

attached to top of

shield not used

framing

 

2 in. (51mm)

clearance

Note: Use same dimensional lumber for framing ceiling firestop and joists.

 

 

A

 

B

Catalog #

in.

 

mm

in.

 

mm

FS338

14-1/2

 

368

14-1/2

 

368

FS339

14-1/2

 

368

18-3/8

 

467

 

 

 

 

 

 

 

FS340

14-1/2

 

368

23

 

584

Figure 23.2 Installing the Ceiling Firestop

Note: You must provide support for the pipe during construction and check to be sure inadvertent loading has not dislodged the chimney section from the fireplace or at any chimney joint.

November 11, 2008

Heatilator • Constitution EPA Fireplace • 480-1091C

Page 23

Image 23
Contents Fire Risk Installation and OperationHot glass will cause burns Serial No Model Name Test Lab Report No Manufactured Date Listing Label Information/LocationTable of Contents Mobile Home Approved Listing and Code ApprovalsAppliance Certification BTU & Efficiency Specifications Glass SpecificationsAsphyxiation Risk Design and Installation ConsiderationsGetting Started Negative PressureNovember 11 Heatilator Constitution EPA Fireplace 480-1091C Typical Fireplace System Typical Fireplace SystemFire Risk Explosion Risk Tools and Supplies NeededInspect Fireplace and Components Model Constitution Framing and ClearancesSelecting Fireplace Location Clearances to Combustible Materials ClearancesNon-Combustible Materials Frame the FireplaceMinimum Clearances to Combustibles Optional Framing Construction / Reduced Mantel HeightSuggestions Electrical Access and Wiring DiagramMaterials Construct the ChaseInstall the Outside Air Kit Installation of FireplaceHandle Right Open Fire Risk Asphyxiation RiskRisk of Smoke Spillage Handle Left ClosedPlace the Protective Metal Hearth Strips Secure the FireplacePosition the Fireplace Position the Protective Metal Hearth Strips Level the FireplaceChimney Assembly Chimney Termination Requirements Chimney RequirementsExample Using Offsets/ReturnsAssembling Chimney Sections for the SL- 300 Series Installing CAK4A and Flex PipeAssemble the Chimney Sections Installing Flex Pipe Install the Ceiling FirestopsSecure the Chimney Install the Attic Insulation ShieldDouble-check the Chimney Assembly Slanted Roofs Complete the EnclosureChimney Termination 2-10-3 Rule Chimney Termination Requirements See Figures 25.1Cut Out the Hole in the Roof Install the Roof FlashingInstall the Chimney Air Kit required in Canada Mark the Exit Point of the RoofConsult local codes for framing details SL-300 Series Ceiling/Roof ThimbleChase Top Framing Install the Termination CapChase Top ‑1/2 in mm below the chase top. See Figure Shock Risk AccessoriesFan Replacement Fan Replacement InstructionsDoor and Door Gasket Baffle Removal and InstallationMinimum Clearance to Combustibles Heat Zone Kit20 ft 3 6m 10 ft 1 3m No cut needed Run Length Cut Pipe Ft 6-12m4 wall Timer Assembly Timer Assembly ReplacementRemove & Replace Timer Timer Override Lever Manual Timer OverrideCalculating Alternate Floor Protection Material FinishingHearth Extension Positioning the Protective Metal Hearth Strips Model # Constitution 1041 508Fascia Outer Tile or Marble Combustible Can Flange Floor Position the Hearth Extension Finishing Material Risk of Fire Non-Combustible Facing Material InstallationMantel Mantel SpecificationsGeneral Information Symptoms of Over-FiringOperating Instructions Over-Firing Your ApplianceKeep open during use Outside AirFan Operation Clear Space Near the FireplaceFirescreen Glass DoorsSeasoning Moisture contentWood Fuel Hardwood vs. Softwood Starting a Fire Storing WoodFire Risk Incorrect Positions Correct Baffle & Blanket PlacementAutomatic Combustion Control ACC Burning ProcessBurn Rate BTU / Hr Slide Air Control Burning GuidelinesBurn Rates OpacityChimney Fire Fire SafetyDraft Problems TroubleshootingUnderstanding Vent Problems Factory-built Fireplaces Troubleshooting Diagnostic Question Possible Causes of Condition Solutions Diagnostics and Problem SolvingDon’t get enough/any heat. What can I do about it? Creosote Chimney Cleaning Maintenance and Servicing the FireplaceGeneral Maintenance CleanFire Risk Injury Risk Glass ReplacementGlass Cleaning Disposal of AshesFirebrick Replacement Inspect Maintenance Tasks Care and Cleaning of Plated SurfacesMaintenance Task List Date of Service Performed By Description of Service Service & Maintenance LogConstitution Fireplace DimensionsReference Materials Chimney Components 15-3/4 NorthStar Fireplace Diagram Parts DiagramEnding Manufacturing Date Service PartsConstitution FP Beginning Manufacturing DateDescription Comments Serial Number Date SL1This page intentionally left blank CONDITIONS, Exclusions & Limitation of Liability Warranty Policy Hearth & Home Technologies Limited WarrantyHearth & Home Technologies Limited Warranty Cont’d Do not Discard this Manual Contact Information

C-40 specifications

Hearth and Home Technologies (HHT) has long been known for its commitment to innovation and quality in the heating and home comfort industry. One of their standout offerings is the C-40, a versatile and efficient gas fireplace that embodies the brand’s dedication to modern aesthetics and advanced technology. This fireplace is designed to not only provide warmth but also enhance the ambiance of any living space.

The C-40 features a sleek, contemporary design that can seamlessly fit into various interior styles. Its clean lines and minimalist frame allow it to serve as a stylish focal point in a room, while offering the functionality and performance that homeowners expect from a high-quality gas fireplace. The unit is available in various configurations, including built-in and wall-mounted options, allowing for flexibility in installation and design.

One of the most notable features of the C-40 is its impressive heat output. With the ability to deliver efficient and evenly distributed warmth, this gas fireplace can effectively heat spaces of various sizes, making it an excellent choice for both small and large rooms. The adjustable flame height feature further enhances the user experience, allowing homeowners to customize their heating preference and create the perfect atmosphere for any occasion.

The C-40 is equipped with cutting-edge technologies, including electronic ignition and a remote control system, making it convenient and easy to use. The electronic ignition ensures quick and reliable startup, while the remote control allows for effortless temperature and flame adjustment from anywhere in the room. This added convenience is a significant benefit for those who value comfort and ease of operation.

Additionally, the C-40 incorporates advanced safety features, such as an automatic shut-off and a secure glass front, providing peace of mind for families. The glass front not only enhances safety but also serves to display the mesmerizing flames beautifully, allowing everyone to enjoy its warmth and glow.

In summary, Hearth and Home Technologies’ C-40 is a prime example of combining stylish design with modern technology and efficiency. Its exceptional heat output, customizable features, and advanced safety measures make it a standout choice for homeowners looking to enhance their living spaces with a dependable gas fireplace. Whether for cozy family gatherings or quiet evenings at home, the C-40 offers both aesthetic appeal and functional excellence, ensuring it remains a popular choice in contemporary home design.