Hearth and Home Technologies C-40 warranty Install the Termination Cap, Chase Top Framing

Page 28

C. Chase Top

A metal chase top is required to seal the top of the chase around the chimney pipe. The top should include a turn- down and drip edge to prevent water from seeping into the chase. Provide a 1/8 in. (3 mm) gap around the flue pipe and slope the top downward away from the penetration. See Figure 28.1.

All seams must be caulked to prevent leaks.

A chase installation must use a chase top. Chase tops are available from your Heatilator dealer or may be field constructed.

Attach the chase top to the top of the chase.

Termination Cap

2 in. (51 mm) Collar on Chase Top

Caulk

Storm Collar

Slope Downward

Turn-down

Drip Edge

Chase (Chimney)

.018 (26 ga) min. Galvanized Chase Top

Figure 28.1 Chase Top Construction

Chase Top Framing

Framing to top of chase must be constructed to support service persons, snow load, etc. Maintain 2 in. (51 mm) clearance to combustibles. Top of framing should be sheeted with plywood particle board. See Figure 28.2.

Exterior sheeting

Chase top framing

Figure 28.2

WARNING

Fire Risk

Never install a single wall slip section or smoke-pipe in a chase structure.

The higher temperature of this single wall pipe may radiate sufficient heat to combus- tible chase materials to cause a fire.

D. Install the Termination Cap

Note: To protect against the effect of corrosion on those parts exposed to the weather, the termination cap can be painted with a rust-resistant paint.

WARNING

Fire Risk

The minimum overlap of cap to pipe

MUST be met or chimney may separate from cap.

Separation allows sparks, heat and embers to escape.

Install the chimney sections up through the chase enclosure. When using a Round Termination Cap, the uppermost top section of pipe must extend 6 in. (152 mm) above the top of the flashing collar to allow installation of the storm collar and termination cap. See Figure 28.3.

Minimum 1-1/2 in. (38 mm) overlap of cap over pipe

Storm Collar

2 in. (51 mm) min.

6 in. (152mm) min.

Flashing Collar

 

 

 

2 in. (51

mm) min. collar

 

 

Figure 28.3 Installing a TR344 Round Termination Cap

For installations utilizing a Round Telescoping Termination Cap, the uppermost chimney section must be below the top of the chase top, but not more than 14‑1/2 in. (368 mm) below the top of the chase top. Minimum overlap of chimney and termination cap must be 1-1/2 in. (38 mm).

See Figure 29.1 on page 29.

Page 28

Heatilator • Constitution EPA Fireplace • 480-1091C

November 11, 2008

Image 28
Contents Hot glass will cause burns Installation and OperationFire Risk Listing Label Information/Location Serial No Model Name Test Lab Report No Manufactured DateTable of Contents Appliance Certification Listing and Code ApprovalsMobile Home Approved Glass Specifications BTU & Efficiency SpecificationsDesign and Installation Considerations Getting StartedNegative Pressure Asphyxiation RiskNovember 11 Heatilator Constitution EPA Fireplace 480-1091C Typical Fireplace System Typical Fireplace SystemInspect Fireplace and Components Tools and Supplies NeededFire Risk Explosion Risk Selecting Fireplace Location Framing and ClearancesModel Constitution Clearances Clearances to Combustible MaterialsFrame the Fireplace Minimum Clearances to CombustiblesOptional Framing Construction / Reduced Mantel Height Non-Combustible MaterialsElectrical Access and Wiring Diagram SuggestionsConstruct the Chase MaterialsInstallation of Fireplace Install the Outside Air KitFire Risk Asphyxiation Risk Risk of Smoke SpillageHandle Left Closed Handle Right OpenPosition the Fireplace Secure the FireplacePlace the Protective Metal Hearth Strips Level the Fireplace Position the Protective Metal Hearth StripsChimney Assembly Chimney Requirements Chimney Termination RequirementsUsing Offsets/Returns ExampleAssemble the Chimney Sections Installing CAK4A and Flex PipeAssembling Chimney Sections for the SL- 300 Series Install the Ceiling Firestops Installing Flex PipeDouble-check the Chimney Assembly Install the Attic Insulation ShieldSecure the Chimney Complete the Enclosure Chimney Termination 2-10-3 RuleChimney Termination Requirements See Figures 25.1 Slanted RoofsInstall the Roof Flashing Install the Chimney Air Kit required in CanadaMark the Exit Point of the Roof Cut Out the Hole in the RoofSL-300 Series Ceiling/Roof Thimble Consult local codes for framing detailsChase Top Install the Termination CapChase Top Framing ‑1/2 in mm below the chase top. See Figure Accessories Fan ReplacementFan Replacement Instructions Shock RiskBaffle Removal and Installation Door and Door GasketHeat Zone Kit Minimum Clearance to CombustiblesRun Length Cut Pipe Ft 6-12m 20 ft 3 6m 10 ft 1 3m No cut needed4 wall Timer Assembly Replacement Timer AssemblyRemove & Replace Timer Manual Timer Override Timer Override LeverHearth Extension FinishingCalculating Alternate Floor Protection Material Model # Constitution 1041 508 Positioning the Protective Metal Hearth StripsFascia Outer Tile or Marble Combustible Can Flange Floor Position the Hearth Extension Finishing Material Non-Combustible Facing Material Installation Risk of FireMantel Specifications MantelSymptoms of Over-Firing Operating InstructionsOver-Firing Your Appliance General InformationOutside Air Keep open during useClear Space Near the Fireplace FirescreenGlass Doors Fan OperationWood Fuel Hardwood vs. Softwood Moisture contentSeasoning Storing Wood Starting a FireFire Risk Correct Baffle & Blanket Placement Incorrect PositionsBurning Process Automatic Combustion Control ACCBurning Guidelines Burn RatesOpacity Burn Rate BTU / Hr Slide Air ControlFire Safety Chimney FireUnderstanding Vent Problems TroubleshootingDraft Problems Factory-built Fireplaces Troubleshooting Diagnostics and Problem Solving Diagnostic Question Possible Causes of Condition SolutionsDon’t get enough/any heat. What can I do about it? Maintenance and Servicing the Fireplace General MaintenanceClean Creosote Chimney CleaningGlass Replacement Glass CleaningDisposal of Ashes Fire Risk Injury RiskFirebrick Replacement Maintenance Task List Care and Cleaning of Plated SurfacesInspect Maintenance Tasks Service & Maintenance Log Date of Service Performed By Description of ServiceReference Materials Fireplace DimensionsConstitution Chimney Components 15-3/4 Parts Diagram NorthStar Fireplace DiagramService Parts Constitution FPBeginning Manufacturing Date Ending Manufacturing DateSL1 Description Comments Serial Number DateThis page intentionally left blank Warranty Policy Hearth & Home Technologies Limited Warranty CONDITIONS, Exclusions & Limitation of LiabilityHearth & Home Technologies Limited Warranty Cont’d Contact Information Do not Discard this Manual

C-40 specifications

Hearth and Home Technologies (HHT) has long been known for its commitment to innovation and quality in the heating and home comfort industry. One of their standout offerings is the C-40, a versatile and efficient gas fireplace that embodies the brand’s dedication to modern aesthetics and advanced technology. This fireplace is designed to not only provide warmth but also enhance the ambiance of any living space.

The C-40 features a sleek, contemporary design that can seamlessly fit into various interior styles. Its clean lines and minimalist frame allow it to serve as a stylish focal point in a room, while offering the functionality and performance that homeowners expect from a high-quality gas fireplace. The unit is available in various configurations, including built-in and wall-mounted options, allowing for flexibility in installation and design.

One of the most notable features of the C-40 is its impressive heat output. With the ability to deliver efficient and evenly distributed warmth, this gas fireplace can effectively heat spaces of various sizes, making it an excellent choice for both small and large rooms. The adjustable flame height feature further enhances the user experience, allowing homeowners to customize their heating preference and create the perfect atmosphere for any occasion.

The C-40 is equipped with cutting-edge technologies, including electronic ignition and a remote control system, making it convenient and easy to use. The electronic ignition ensures quick and reliable startup, while the remote control allows for effortless temperature and flame adjustment from anywhere in the room. This added convenience is a significant benefit for those who value comfort and ease of operation.

Additionally, the C-40 incorporates advanced safety features, such as an automatic shut-off and a secure glass front, providing peace of mind for families. The glass front not only enhances safety but also serves to display the mesmerizing flames beautifully, allowing everyone to enjoy its warmth and glow.

In summary, Hearth and Home Technologies’ C-40 is a prime example of combining stylish design with modern technology and efficiency. Its exceptional heat output, customizable features, and advanced safety measures make it a standout choice for homeowners looking to enhance their living spaces with a dependable gas fireplace. Whether for cozy family gatherings or quiet evenings at home, the C-40 offers both aesthetic appeal and functional excellence, ensuring it remains a popular choice in contemporary home design.