Hearth and Home Technologies C-40 warranty Table of Contents

Page 3

TABLE OF CONTENTS

Section 1: Listing and Code Approvals

A. Appliance Certification . . . . . . . . . . .4 B. Mobile Home Approved. . . . . . . . . . .4 C. Glass Specifications. . . . . . . . . . . .5 D. BTU & Efficiency Specifications . . . . . . . 5

Section 2: Getting Started

A.Design and Installation Considerations. . . . .6

B.Negative Pressure. . . . . . . . . . . . . . . . . . . . . . . .6

C.Typical Fireplace System . . . . . . . . . .8

D.Tools and Supplies Needed . . . . . . . . .9

E.Inspect Fireplace and Components . . . . . .9

Section 3: Framing and Clearances

A. Selecting Fireplace Location. . . . . . . . 10 B. Clearances . . . . . . . . . . . . . . . 11 C. Frame the Fireplace . . . . . . . . . . . 12

D.Electrical Access and Wiring Diagram . . . . 13

E.Construct the Chase. . . . . . . . . . . 14

Section 4: Installation of Fireplace

A.Install the Outside Air Kit. . . . . . . . . .15

B.Secure the Fireplace. . . . . . . . . . . 17

Section 5: Chimney Assembly

A.Chimney Requirements. . . . . . . . . . . . . . . . . . .20

B.Chimney Termination Requirements. . . . . 20

C.Using Offsets/Returns. . . . . . . . . . .21

D.Assemble the Chimney Sections . . . . . . 22

E.Assembling Chimney Sections

for SL-300 Series . . . . . . . . . . . . 22

F.Install the Ceiling Firestops. . . . . . . . .23

G.Install the Attic Insulation Shield. . . . . . .24

H.Double-check the Chimney Assembly. . . . . . . .24

I.Secure the Chimney. . . . . . . . . . . 24

Section 6: Complete the Enclosure

A.Chimney Termination (2-10-3 Rule) . . . . . 25

B.SL-300 Series Ceiling/Roof Thimble. . . . . 27

C.Chase Top. . . . . . . . . . . . . . . 28

D.Install the Termination Cap. . . . . . . . .28

Section 7: Accessories

A. Fan Replacement. . . . . . . . . . . . 30

B.Baffle Removal and Installation. . . . . . . . . . . . .31

C.Door and Door Gasket . . . . . . . . . . 31

D.Heat Zone Kit . . . . . . . . . . . . . .32

E.Timer Assembly Replacement . . . . . . . 35

F.Manual Timer Override. . . . . . . . . . 37

Section 8: Finishing

A.Hearth Extension. . . . . . . . . . . . . . . . . . . . . . . .38 B. Alternate Floor Protection Worksheet . . . . .38 C. Position the Hearth Extension. . . . . . . .41 D. Finishing Material . . . . . . . . . . . . 41 E. Non-Combustible Facing Material Installation. .42 F. Mantel. . . . . . . . . . . . . . . . .43

Section 9: Operating Instructions

A.Over-firing Your Appliance. . . . . . . . . . . . . . . . .44

B.General Information . . . . . . . . . . . 44

C.Outside Air. . . . . . . . . . . . . . . . . . . . . . . . . . . . .45

D.Clear Space Near the Fireplace. . . . . . .46

E.Firescreen. . . . . . . . . . . . . . . 46

F.Glass Doors . . . . . . . . . . . . . . 46

G.Fan Operation. . . . . . . . . . . . . .46

H.Heat Zone Operation. . . . . . . . . . . . . . . . . . . . .46

I.Wood Fuel. . . . . . . . . . . . . . . 47

J.Starting a Fire. . . . . . . . . . . . . .48

K.Correct Baffle & Blanket Placement. . . . . 50

L.Burning Process. . . . . . . . . . . . .51

M.Automatic Combustion Control (ACC) . . . . 51

N.Burning Guidelines. . . . . . . . . . . .52

O.Burn Rates . . . . . . . . . . . . . . .52

P.Opacity . . . . . . . . . . . . . . . . 52

Q.Overfiring. . . . . . . . . . . . . . . .53

R.Chimney Fire. . . . . . . . . . . . . . 53

Section 10: Troubleshooting

A. Understanding Vent Problems . . . . . . . 54 B. Draft Problems . . . . . . . . . . . . . 54 C. Diagnostics and Problem Solving. . . . . . 56

Section 11: Maintenance and Servicing the Fireplace

A. General Maintenance. . . . . . . . . . .58 B. Glass Replacement. . . . . . . . . . . .59 C. Brick Replacement . . . . . . . . . . . .60

D.Care and Cleaning of Plated Surfaces. . . . 61 E. Maintenance Task List. . . . . . . . . . .61

F. Service & Maintenance Log . . . . . . . . 62

Section 12: Reference Materials

A. Fireplace Dimensions. . . . . . . . . . .63

B.Chimney Components. . . . . . . . . . . . . . . . . . . .64

C.Parts Diagrams. . . . . . . . . . . . . 66

D.Service Parts. . . . . . . . . . . . . . 67

E.Warranty Policy. . . . . . . . . . . . . 70

F.Contact Information. . . . . . . . . . . .72

November 11, 2008

Heatilator • Constitution EPA Fireplace • 480-1091C

Page

Image 3
Contents Installation and Operation Hot glass will cause burnsFire Risk Serial No Model Name Test Lab Report No Manufactured Date Listing Label Information/LocationTable of Contents Listing and Code Approvals Appliance CertificationMobile Home Approved BTU & Efficiency Specifications Glass SpecificationsAsphyxiation Risk Design and Installation ConsiderationsGetting Started Negative PressureNovember 11 Heatilator Constitution EPA Fireplace 480-1091C Typical Fireplace System Typical Fireplace SystemTools and Supplies Needed Inspect Fireplace and ComponentsFire Risk Explosion Risk Framing and Clearances Selecting Fireplace LocationModel Constitution Clearances to Combustible Materials ClearancesNon-Combustible Materials Frame the FireplaceMinimum Clearances to Combustibles Optional Framing Construction / Reduced Mantel HeightSuggestions Electrical Access and Wiring DiagramMaterials Construct the ChaseInstall the Outside Air Kit Installation of FireplaceHandle Right Open Fire Risk Asphyxiation RiskRisk of Smoke Spillage Handle Left ClosedSecure the Fireplace Position the FireplacePlace the Protective Metal Hearth Strips Position the Protective Metal Hearth Strips Level the FireplaceChimney Assembly Chimney Termination Requirements Chimney RequirementsExample Using Offsets/ReturnsInstalling CAK4A and Flex Pipe Assemble the Chimney SectionsAssembling Chimney Sections for the SL- 300 Series Installing Flex Pipe Install the Ceiling FirestopsInstall the Attic Insulation Shield Double-check the Chimney AssemblySecure the Chimney Slanted Roofs Complete the EnclosureChimney Termination 2-10-3 Rule Chimney Termination Requirements See Figures 25.1Cut Out the Hole in the Roof Install the Roof FlashingInstall the Chimney Air Kit required in Canada Mark the Exit Point of the RoofConsult local codes for framing details SL-300 Series Ceiling/Roof ThimbleInstall the Termination Cap Chase TopChase Top Framing ‑1/2 in mm below the chase top. See Figure Shock Risk AccessoriesFan Replacement Fan Replacement InstructionsDoor and Door Gasket Baffle Removal and InstallationMinimum Clearance to Combustibles Heat Zone Kit20 ft 3 6m 10 ft 1 3m No cut needed Run Length Cut Pipe Ft 6-12m4 wall Timer Assembly Timer Assembly ReplacementRemove & Replace Timer Timer Override Lever Manual Timer OverrideFinishing Hearth ExtensionCalculating Alternate Floor Protection Material Positioning the Protective Metal Hearth Strips Model # Constitution 1041 508Fascia Outer Tile or Marble Combustible Can Flange Floor Position the Hearth Extension Finishing Material Risk of Fire Non-Combustible Facing Material InstallationMantel Mantel SpecificationsGeneral Information Symptoms of Over-FiringOperating Instructions Over-Firing Your ApplianceKeep open during use Outside AirFan Operation Clear Space Near the FireplaceFirescreen Glass DoorsMoisture content Wood Fuel Hardwood vs. SoftwoodSeasoning Starting a Fire Storing WoodFire Risk Incorrect Positions Correct Baffle & Blanket PlacementAutomatic Combustion Control ACC Burning ProcessBurn Rate BTU / Hr Slide Air Control Burning GuidelinesBurn Rates OpacityChimney Fire Fire SafetyTroubleshooting Understanding Vent ProblemsDraft Problems Factory-built Fireplaces Troubleshooting Diagnostic Question Possible Causes of Condition Solutions Diagnostics and Problem SolvingDon’t get enough/any heat. What can I do about it? Creosote Chimney Cleaning Maintenance and Servicing the FireplaceGeneral Maintenance CleanFire Risk Injury Risk Glass ReplacementGlass Cleaning Disposal of AshesFirebrick Replacement Care and Cleaning of Plated Surfaces Maintenance Task ListInspect Maintenance Tasks Date of Service Performed By Description of Service Service & Maintenance LogFireplace Dimensions Reference MaterialsConstitution Chimney Components 15-3/4 NorthStar Fireplace Diagram Parts DiagramEnding Manufacturing Date Service PartsConstitution FP Beginning Manufacturing DateDescription Comments Serial Number Date SL1This page intentionally left blank CONDITIONS, Exclusions & Limitation of Liability Warranty Policy Hearth & Home Technologies Limited WarrantyHearth & Home Technologies Limited Warranty Cont’d Do not Discard this Manual Contact Information

C-40 specifications

Hearth and Home Technologies (HHT) has long been known for its commitment to innovation and quality in the heating and home comfort industry. One of their standout offerings is the C-40, a versatile and efficient gas fireplace that embodies the brand’s dedication to modern aesthetics and advanced technology. This fireplace is designed to not only provide warmth but also enhance the ambiance of any living space.

The C-40 features a sleek, contemporary design that can seamlessly fit into various interior styles. Its clean lines and minimalist frame allow it to serve as a stylish focal point in a room, while offering the functionality and performance that homeowners expect from a high-quality gas fireplace. The unit is available in various configurations, including built-in and wall-mounted options, allowing for flexibility in installation and design.

One of the most notable features of the C-40 is its impressive heat output. With the ability to deliver efficient and evenly distributed warmth, this gas fireplace can effectively heat spaces of various sizes, making it an excellent choice for both small and large rooms. The adjustable flame height feature further enhances the user experience, allowing homeowners to customize their heating preference and create the perfect atmosphere for any occasion.

The C-40 is equipped with cutting-edge technologies, including electronic ignition and a remote control system, making it convenient and easy to use. The electronic ignition ensures quick and reliable startup, while the remote control allows for effortless temperature and flame adjustment from anywhere in the room. This added convenience is a significant benefit for those who value comfort and ease of operation.

Additionally, the C-40 incorporates advanced safety features, such as an automatic shut-off and a secure glass front, providing peace of mind for families. The glass front not only enhances safety but also serves to display the mesmerizing flames beautifully, allowing everyone to enjoy its warmth and glow.

In summary, Hearth and Home Technologies’ C-40 is a prime example of combining stylish design with modern technology and efficiency. Its exceptional heat output, customizable features, and advanced safety measures make it a standout choice for homeowners looking to enhance their living spaces with a dependable gas fireplace. Whether for cozy family gatherings or quiet evenings at home, the C-40 offers both aesthetic appeal and functional excellence, ensuring it remains a popular choice in contemporary home design.