3100 Wood Stove Series (ACC)
B. Clearances to Combustibles (UL and ULC)
BACKWALL / SIDEWALL
A | B |
| C |
| D |
CORNER INSTALLATION
E |
F |
E |
F |
NOTE: Clearances may only be reduced by means approved by the regulatory authority having jurisdiction
90° OFF TOP | H* |
UP & OUT CEILING | G |
CLEARANCE |
|
STOVE TO CEILING |
|
CLEARANCE |
|
ALCOVE SIDE VIEW
G | A |
| |
| B |
ALCOVE TOP VIEW
C
D
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS In Inches & (Millimeters)
NOTE: All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar.
| A | B | C | D | E | F | G | H |
INSTALLATION: Full Vertical OR Horizontal with Minimum 2 FT Vertical Off Stove Top |
|
|
| |||||
SINGLE WALL PIPE |
|
|
|
|
|
|
|
|
Flat Top Model | 15.25 (387) 11.75 (298) | 25.5 (648) | 16 (406) | 8 (203) | 17 (432) | 48 (1220) | 12 (305) | |
12 (305) | 8.5 (216) | 22 (559) | 12.5 (318) | 5.5 (140 | 14.5 (368) | 48 (1220) | 12 (305) | |
DOUBLE WALL PIPE |
|
|
|
|
|
|
|
|
Flat Top Model | 10.5 (267) | 6.5 (165) | 22 (559) | 13 (330) | 6.5 (165) | 15.5 (394) | 48 (1220) | 9 (229) |
10 (228) | 6 (152) | 20.5 (521) | 11 (279) | 4 (102) | 13 (330) | 48 (1220) | 9 (229) | |
INSTALLATION: 90° Elbow Off Top of Stove Through Backwall |
|
|
|
|
| |||
SINGLE WALL PIPE |
|
|
|
|
|
|
|
|
Flat Top Model | 12 (305) | 8.5 (216) | 22 (559) | 13 (330) | 8 (203) | 17 (432) | 48 (1220) | 12 (305) |
10 (254) | 6 (152) | 20.5 (521) | 11 (279) | 5.5 (140) | 14.5 (368) | 48 (1220) | 12 (305) | |
DOUBLE WALL PIPE |
|
|
|
|
|
|
|
|
Flat Top Model | 8 (203) | 4.5 (114) | 17.5 (445) | 8.5 (216) | 6.5 (165) | 15.5 (394) | 48 (1220) | 9 (229) |
10 (254) | 6 (152) | 20.5 (521) | 11 (279) | 4 (102) | 13 (330) | 48 (1220) | 9 (229) |
INSTALLATION: ALCOVE Six inch (6") (152mm) diameter listed Double Wall air insulated connector pipe with UL103 HT* listed
*In Canada must comply with
DOUBLE WALL PIPE |
|
|
|
|
|
|
|
|
Flat Top Model | 11.75 (298) | 8.25 (210) | 23.5 (597) | 14.5 (368) | N/A | N/A | 48 (1220) | * |
10 (254) | 6.5 (152) | 20.5 (521) | 11 (279) | N/A | N/A | 48 (1220) | * |
* SEE PIPE MANUFACTURERS CLEARANCES - NOT TESTED
WARNING
Fire Risk.
•Comply with all minimum clearances to combustibles as specified.
•Failure to comply may cause house fire.
NOTE: Service Space
In order to replace the tube channel assembly a clearance of 19 inches (483mm) is required on the right side of stove in order to remove the tubes with the stove in place.
If space is not available, the stove will have to be discon- nected from the chimney to proceed with the tube replace- ment.
September 1, 2008 |
| Page 11 |