Hearth and Home Technologies 31ST-ACC, 31M-ACC-MBK owner manual Step-Top Uni-Body Model

Page 40

3100 Wood Stove Series (ACC)

R

 

 

 

25

39

 

 

 

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23

22

 

 

 

 

 

 

 

 

 

 

 

 

 

50

 

26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

51

14

 

12

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

 

 

 

 

 

 

 

9

19

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

29

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

4

6

7

 

 

 

49

 

 

 

16

 

 

 

 

 

 

 

 

 

 

 

34

 

 

 

 

 

 

 

31

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

 

 

 

 

 

 

 

 

 

 

32

 

33

 

52

 

 

 

37

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

SIZES

36

 

 

 

 

 

(#33)

Baffle Board: 9-1/2” w x 13-3/4” h, each

 

35

 

 

Step-Top Uni-Body Model

(#29)

Ceramic Blanket: 19” w x 13-3/4” h, 1/2” thick

 

 

 

 

 

 

 

Figure 40.1

Item

Description

Item

Description

1

Oak Strip for Pedestal

26

Air Channel Assembly, Rear

4

Knob, Start-Up Air Control

28

Tube Support Rack

5

Magnet for Air Control

29

Blanket, Ceramic

6

Air Control Rod Guide, Start-Up

30

Hinge Pin

7

Control Arm Assembly, Rear Air

31

Door, Cast (not sold separately)

9

Timer, Mechanical

32

Spring Handle, 1/2 inch

10

Timer Arm Assembly

33

Baffle Fiberboard, (2 pc)

12

Gasket, Front & Rear Air Doors

34

Brick Retainer

13

Burn Rate Air Control Assembly

35

Legs, Queen Anne

14

Spring Handle, 1/4 inch

36

Pedestal, Ash Removal System

16

Label for Burn Rate Air Control

37

Ash Pan, Ash Removal System

17

Label for Start-Up Air Control

39

Flue Collar (can’t replace in the field)

18

Panel Assembly, Side, Right

49

Timer Air Control Assembly

19

Tube Channel Access Cover (Top)

50

Brick, Set

20

Tube Channel Assembly

51

Grate, Ash Removal

21

Air Channel, Convection

52

Bracket, Leg Mount, Left & Right (set)

22Bracket, Convection Mount

23Air Supply, Back

25Panel Assembly, Side, Left

Page 40

7033-277F

September 1, 2008

Image 40
Contents Step Top Uni-Body Model Millennium Model Hot glass will cause burns7033-277F September 1Wood Stove Series ACC 007Serial No Model Name Mfg. Date 7033-277F September 1Table of Contents Appliance Certification BTU & Efficiency Specifications Glass SpecificationsListing and Code Approvals Mobile Home ApprovedFire Safety Getting StartedWood Stove Series ACC Negative Pressure 7033-277F September 1Wood Stove Series ACC Flue Draft Considerations Venting SystemsTools And Supplies Needed Inspect Appliance & Components and Pre-Use Check ListWood Stove Series ACC Typical Stove Systems Masonry ChimneyAppliance Dimensions Dimensions and ClearancesMillennium Model 11/16 in mm 89mm Back of Stove to Glass 11/16 in mm10-/8 in mm 21-1/8 in 7mm 7033-277F September 1 Wood Stove Series ACC Clearances to Combustibles UL and ULC Double Wall PipeInstallation 31004Wood Stove Series ACCHearth Protection Requirements Millennium ModelWood Stove Series ACC Step-Top Uni-Body Model Items Needed for Installation not supplied Wood Stove Series ACC Outside Air Kit InstallationFire Risk Asphyxiation Risk Wood Stove Series ACC Blower Optional Shock RiskChimney Connector Chimney RequirementsVenting Components Chimney Systems ThimbleComponents Air ClearancesInstructions Solid Pack Chimney with Metal Supports as a ThimbleSolid Pack Chimney with Metal Supports as a Thimble Cont’d Installing Chimney ComponentsChimney Height / Rise and Run Wood Stove Series ACC Chimney Termination Requirements RulePitched Roof Flat RoofMobile Home Installation Appliance Set Up Begin installing the ARS SystemInstalling Pedestal Assembly Finishing the ARS InstallationInstalling Leg Kit Corners. FigureWood Stove Series ACC Door Handle Assembly Adjusting The Blower Speed ControlOperating Instructions Over-Firing Your Appliance Wood Selection & Storage Cont’dWood Selection & Storage Burning ProcessAutomatic Combustion Control ACC Air ControlsBurn Rates and Operating Efficiency Wood Stove Series ACC Building a Fire Wood Stove Series ACC Correct Baffle & Blanket Placement Incorrect PositionsFrequently Asked Questions Opacity Smoke Initial cold start-up and all Burn SettingsWood Stove Series ACC Blower Operating Instructions Snap Disc LocationGeneral Maintenance Ash Removal System ARS Operating and CleaningCreosote Chimney Cleaning Maintaining & Servicing Your ApplianceGlass Cleaning Frequency As desired Cleaning Plated SurfacesWhen cleaning glass Disposal of AshesWood Stove Series ACC Glass Replacement Wood Stove Series ACC Firebrick Replacement Appliance without firebrickTo your authorized dealer Brick Size QtyWood Stove Series ACC Baffle Removal Snap Disc Replacement Snap Disc LocationRemoving Tube Channel Assembly Wood Stove Series ACC Tube Channel Assembly ReplacementReplacing Tube Channel Assembly Troubleshooting Start Fire Problems Possible Cause SolutionReference Materials Exploded view#33 Baffle Board 2 w x 13-3/4 h, each #29 Ceramic Blanket 19 w x 13-3/4 h, 1/2 thickStep-Top Uni-Body Model Flue Collar can’t replace in the fieldWood Stove Series ACC Service Parts & Accessories Blower AssemblyItem # Service Parts Item # Service Parts Wood Stove Series ACC Service And Maintenance Log Date of Service Performed By Description of ServiceWood Stove Series ACC Homeowner’s Notes CONDITIONS, Exclusions & Limitation of Liability September 1 7033-277F Contact Information