R
3100 Wood Stove Series (ACC)
H. Correct Baffle & Blanket Placement | INCORRECT POSITIONS |
WARNING
Fire Risk
Firebox damage due to improper baffle place-
ment is not covered by warranty. Operate the wood burning appliance with the baffle in the correct position only.
Not doing so could result in:
•Reduced efficiency
•Overheating the chimney
•Overheating the rear of the firebox
•Poor performance
Ensure correct baffle placement and replace baffle com- ponents if damaged or missing.
CORRECT POSITION
Ceramic Blanket and Baffle Board are NOT in contact with the back of the firebox.
Ceramic Blanket
Back of Firebox
Ceramic Blanket is NOT in contact with the back of the firebox and NOT even with the Baf- fle Board in the front.
Baffle Board
Ceramic Blanket
Back of Firebox
Ceramic Blanket and Baffle Board MUST be in contact with the back of the firebox and even with each other in the front.
Figure 29.1
Baffle Board
Ceramic Blanket is bunched up at the back of the firebox and NOT even with the Baffle Board in the front.
Figure 29.2
September 1, 2008 |
| Page 29 |