Hearth and Home Technologies 31ST-ACC Listing and Code Approvals, Mobile Home Approved

Page 4

3100 Wood Stove Series (ACC)

R

 

 

 

 

 

 

 

 

 

 

 

1 Listing and Code Approvals

 

 

 

 

 

 

A. Appliance Certification

D. BTU & Efficiency Specifications

Model:

3100 Millennium & Step Top Uni-Body

 

(ACC)

Laboratory:

OMNI Test Laboratories, Inc.

Report No & Date:

061-S-66-6

Type:

Listed Room Heater, Solid Fuel Type

Standard:

UL1482 and ULC S627-00 and

 

(UM) 84-HUD, Mobile Home

 

Approved.

The Quadra-Fire 3100 Series Wood Stove (ACC) meets the U.S. Environmental Protection Agency’s 1990 particulate emission standards.

EPA Certified:

1.1 grams per hour

EPA Certification

Number: 369

Number and Date:

Issued: 2006

Efficiency:

79.51%

BTU Output:

11,800 to 32,000

 

 

Heating Capacity:

up to1,800 sq ft

 

depending on climate zone

 

 

Vent Size:

6 inches

Firebox Size:

2 cubic feet

Max Wood Length:

18 inches

Fuel:

Cord Wood

Shipping Weight:

325 lbs

B. Mobile Home Approved

This appliance is approved for mobile home installations when not installed in a sleeping room and when an outside combustion air inlet is provided. The structural integrity of the mobile home floor, ceiling, and walls must be maintained. The appliance must be properly grounded to the frame of the mobile home and use only listed double-wall connector pipe. Outside Air Kit, part OAK-ACC must be installed in a mobile home installation

NOTE: Hearth & Home Technologies, manufacturer of this appliance, reserves the right to alter its products, their specifications and/or price without notice.

C. Glass Specifications

This stove is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass.

NOTE: This installation must conform with local codes. In the absence of local codes you must comply with the UL1482, (UM) 84-HUD and NPFA211 in the U.S.A. and the ULC S627-00 and CAN/CSA-B365 Installation Codes in Canada.

Page

7033-277F

September 1, 2008

Image 4
Contents Step Top Uni-Body Model Millennium Model Hot glass will cause burns7033-277F September 1Wood Stove Series ACC 007Serial No Model Name Mfg. Date 7033-277F September 1Table of Contents Appliance Certification BTU & Efficiency Specifications Glass SpecificationsListing and Code Approvals Mobile Home ApprovedFire Safety Getting StartedWood Stove Series ACC Negative Pressure 7033-277F September 1Wood Stove Series ACC Flue Draft Considerations Venting SystemsTools And Supplies Needed Inspect Appliance & Components and Pre-Use Check ListWood Stove Series ACC Typical Stove Systems Masonry ChimneyAppliance Dimensions Dimensions and ClearancesMillennium Model 11/16 in mm 89mm Back of Stove to Glass 11/16 in mm10-/8 in mm 21-1/8 in 7mm 7033-277F September 1 Wood Stove Series ACC Clearances to Combustibles UL and ULC Double Wall PipeInstallation 31004Wood Stove Series ACCHearth Protection Requirements Millennium ModelWood Stove Series ACC Step-Top Uni-Body Model Items Needed for Installation not supplied Wood Stove Series ACC Outside Air Kit InstallationFire Risk Asphyxiation Risk Wood Stove Series ACC Blower Optional Shock RiskChimney Connector Chimney RequirementsVenting Components Chimney Systems ThimbleComponents Air ClearancesInstructions Solid Pack Chimney with Metal Supports as a ThimbleSolid Pack Chimney with Metal Supports as a Thimble Cont’d Installing Chimney ComponentsChimney Height / Rise and Run Wood Stove Series ACC Chimney Termination Requirements RulePitched Roof Flat RoofMobile Home Installation Appliance Set Up Begin installing the ARS SystemInstalling Pedestal Assembly Finishing the ARS InstallationInstalling Leg Kit Corners. FigureWood Stove Series ACC Door Handle Assembly Adjusting The Blower Speed ControlOperating Instructions Over-Firing Your Appliance Wood Selection & Storage Cont’dWood Selection & Storage Burning ProcessAutomatic Combustion Control ACC Air ControlsBurn Rates and Operating Efficiency Wood Stove Series ACC Building a Fire Wood Stove Series ACC Correct Baffle & Blanket Placement Incorrect PositionsFrequently Asked Questions Opacity Smoke Initial cold start-up and all Burn SettingsWood Stove Series ACC Blower Operating Instructions Snap Disc LocationGeneral Maintenance Ash Removal System ARS Operating and CleaningCreosote Chimney Cleaning Maintaining & Servicing Your ApplianceGlass Cleaning Frequency As desired Cleaning Plated SurfacesWhen cleaning glass Disposal of AshesWood Stove Series ACC Glass Replacement Wood Stove Series ACC Firebrick Replacement Appliance without firebrickTo your authorized dealer Brick Size QtyWood Stove Series ACC Baffle Removal Snap Disc Replacement Snap Disc LocationRemoving Tube Channel Assembly Wood Stove Series ACC Tube Channel Assembly ReplacementReplacing Tube Channel Assembly Troubleshooting Start Fire Problems Possible Cause SolutionReference Materials Exploded view#33 Baffle Board 2 w x 13-3/4 h, each #29 Ceramic Blanket 19 w x 13-3/4 h, 1/2 thickStep-Top Uni-Body Model Flue Collar can’t replace in the fieldWood Stove Series ACC Service Parts & Accessories Blower AssemblyItem # Service Parts Item # Service Parts Wood Stove Series ACC Service And Maintenance Log Date of Service Performed By Description of ServiceWood Stove Series ACC Homeowner’s Notes CONDITIONS, Exclusions & Limitation of Liability September 1 7033-277F Contact Information