3.3ELECTRICAL REQUIREMENTS

3.3.1ELECTRICAL DATA (FOR 230/208V MODEL)

CAUTION

1.Do not use an extension cord with this unit.

2.When the unit is in the OFF position, the power supply to the electrical controls is still energized.

3.Disconnect the power to the unit before servicing the unit.

4.Remove the power cord from the wall receptacle.

5.Remove or turn off the protective device (fuses or circuit breaker).

Wirings including installation of the receptacle must comply with the NEC and local codes, local regulations.

FUSE- Use a time-delay fuse or circuit breaker. Refer to the nameplate for proper power supply requirements.

3.3.2 ELECTRICAL SAFETY

IMPORTANT GROUNDING INSTRUCTIONS

Tandem

15 A

Perpendicular

20 A

Large Tandem

30 A

230/208 volt receptacle configuration

The air conditioner has a three-prong grounding plug on its power supply cord which must be plugged into properly grounded three-prong wall receptacle for your protection against possible shock hazard.

FUSE – Use a time-delay fuse or circuit breaker. Refer to the nameplate for proper power supply requirements.

208, 230, and 208/230 VOLT UNITS

These units are equipped with a three-prong grounding plug on the power supply cord which must be plugged into a matching properly grounded three-prong wall receptacle for your protection against possible shock hazard. If such an outlet is not present, one must be installed by a qualified electrician in accordance with the National Electrical Code and local codes and ordinances.

NOTE: DO NOT USE AN EXTENSION CORD on 208, 230, and 208/230 Volt units.

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 23 -

Only for training and service purposes

LGE Internal Use Only

 

Image 23
Contents SVC Manual LGE Internal Use Only SpecificationSleeve and the Rear Grille Features and BenefitsQuick Heater Recovery Door Switch/Occupancy SensorOutdoor Air Temperature Switchover Temperature limitsCooling only Model Control LocationsOperation Electric Heating Model VentilationAdditional Controls Temperature LimitingAdditional Controls Removing the Front GrilleFront Desk Control Molex Housing SpecREMOTE/LOCAL Control Energy SaverFront Grille Disassembly InstructionsMechanical Parts Control BOX Electric Heater Electric Heater Model only AIR Handling PartsAxial FAN Cross Flow FANCompressor Electrical PartsShroud Outdoor Motor6 P.C.B Power CordCapillary Tube Refrigeration CycleCondenser EvaporatorLGE Internal Use Only Pulling Vacuum Dimension of sleeve assembly optional InstallationHOW to Install the Unit Dimension of air conditionerGeneral Wall Sleeve InstallationWall Case Installation Data Preparation of the Wall Case for All Types of Construction Installation of Wall Case in Wall OpeningAs shipped, the LG wall sleeve is ready for installation Preparation of the Front GrilleLGE Internal Use Only Sub-Base Connected Unit Installation 208, 230, and 208/230 Volt Units Electrical SafetyElectrical Requirements Electrical Data for 230/208V ModelDescription Field Installed AccessoriesInstallation Control Panel Key LockHazardous Voltage Condensate Disposal Pump Kit InstallationPart No AYSB2101 Place the top cover assembly back into the unit Spraying Architectural Grille Architecture Grille Aluminum Single PackPart No AYDR101 Drain InstallationCondensate Drain kit Outdoor Drain Kit Installation Outdoor Drain Kit InstallationPart No AYLL101 Indoor Drain Kit InstallationChecklist Leveling LegsLeveling Leg Assembly Installation on Wall Sleeve Leveling Leg AssemblyUse Copper Conductors Only Hard Wire KitJunction Box Kit Installation and Wiring Procedure Part No AYAGALA01Volt Units 208/230 Volt UnitsPart No AYRE110 Remote Escutcheon KitPart No AYSB1101 230/208V 20A AYSB2101 230/208V 30A SubbaseSubbase with provided screws. Figure After wiring is complete, mount covers a and F toTo each installation instruction for that accessory Skirting Hole Location Right Cover Assembly066mm 406mm 505mm Troubleshooting GuideOutside Dimensions Piping SystemTroubleshooting Guide Fails to Start Complaint Cause Remedy 208/230V 187V 253V Room AIR Conditioner Voltage LimitsComplaint Cause Remedy Th4 Thermistor for Condenser pipe Air temperature Piping DiagramsTh2 Thermistor for Evaporator pipe temperature Th3 Thermistor for outdoor Air temperatureCN-NN Schematic Diagram435300B Exploded ViewJanuary