Indoor Drain Kit Installation
The internal drain is installed on the bottom of the wall sleeve when it is required to drain the condensate into a drain system inside of the building.
The components of the wall sleeve drain kit are shown in Detail A. Use components C (2), D, E, mounting screws (6) and the Outdoor drain fitting.
1.The components D, E, and drain fitting of the kit are mounted on the bottom of the wall sleeve prior to the installation of the sleeve. It may be located in a feasible area on the bottom of the sleeve which is inside of the room except when a subbase is used. When a subbase is installed, the drain may be a minimum of 3 1/2 " from the front flange of the wall sleeve. The minimum clearance should provide adequate clearance for the subbase, see Figures 46 and 47.
2.Cut out the template in the lower right hand corner of these instructions to locate the field drilled holes. (Two to mount the plate and one for the Outdoor drain fitting). See Detail A on how the components have to be installed after the holes are drilled in the bottom of the wall sleeve. If the drain fitting is not connected to an indoor drainage system immediately after the wall sleeve is installed, it must be plugged with a cork to prevent indoor water damage in case it rains.
An indoor tube or hose (furnished by others) must be installed on the drain fitting and interconnected to the drain system inside of the building.
Install the two
Figure 47
Leveling Legs
Part No: AYLL101
Description
Leveling legs are designed to provide extra front support and leveling of the wall sleeve. Two leg assemblies are required per unit and are provided in each kit. Four screws are also provided with each kit for attachment to the wall
sleeve. See Figure 48.
The leveling legs must be installed before the chassis is installed, but after the wall sleeve is in place.
Holes must be drilled in each side of the wall sleeve, below the duct package holes, for attachment to the wall sleeve.
Receiving
•Compare kit identification number with sales order to ensure that the correct kit has been received.
•Inspect the leveling legs for shipping damage. File damage claims with the delivering carrier immediately.
Installation
The installation and servicing of this equipment should be performed by qualified, experienced technicians.
WARNING
Hazardous Voltage!
Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/tagout procedures to ensure the power can not be inadvertently energized. Failure to disconnect power before servicing could result in death or serious injury.
Important Note:
The unit OFF switch does not disconnect all electrical power to this unit.
Checklist
The following is an abbreviated guide to leveling leg installation. Refer to appropriate areas for more detailed information.