LG Electronics LP121HEM-Y8 manual Control Locations, Operation Electric Heating Model, Ventilation

Page 5

1.3 CONTROL LOCATIONS

OPERATION

ELECTRIC HEATING MODEL

TEMPERATURE CONTROL

Set the Thermostat control to the desired temperature mark 5 (the mid-point is a good starting position). If the room temperature is not satisfactory after a reasonable time, adjust the control to a cooler or warmer setting, as appropriate.

VENTILATION

The ventilation lever is located to the lower left side of the unit. The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions.

When fresh air is necessary in the room, set the ventilation lever to the OPEN position.

The damper is opened and outdoor air is drawn into the room. This will reduce the cooling or heating efficiency.

CAUTION

When the air conditioner has performed a cooling or heating operation and is turned off or set to the fan position, wait at least 3 minutes before resetting to the cooling operation.

COOLING ONLY MODEL

OPERATION MODE SELECTOR

OFF

Turns air conditioner off.

LOW FAN

Low speed fan operation without cooling.

HIGH FAN

High speed fan operation without cooling.

LOW COOL

Cooling with the low speed fan operation.

HIGH COOL

Cooling with the high speed fan operation.

LOW HEAT

Heating with the low speed fan operation.

HIGH HEAT

Heating with the high speed fan operation.

VENT

VENT CLOSE

OPEN

NOTE

A slight heat odor may come from the unit when first switching to HEAT after the cooling season is over.

This odor, caused by fine dust particles on the heater, will disappear quickly. This is harmless.

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 5 -

Only for training and service purposes

LGE Internal Use Only

 

Image 5
Contents SVC Manual LGE Internal Use Only SpecificationSleeve and the Rear Grille Features and BenefitsOutdoor Air Temperature Switchover Door Switch/Occupancy SensorTemperature limits Quick Heater RecoveryOperation Electric Heating Model Control LocationsVentilation Cooling only ModelAdditional Controls Temperature LimitingRemoving the Front Grille Additional ControlsREMOTE/LOCAL Control Molex Housing SpecEnergy Saver Front Desk ControlFront Grille Disassembly InstructionsMechanical Parts Control BOX Electric Heater Electric Heater Model only AIR Handling PartsAxial FAN Cross Flow FANShroud Electrical PartsOutdoor Motor Compressor6 P.C.B Power CordCondenser Refrigeration CycleEvaporator Capillary TubeLGE Internal Use Only Pulling Vacuum HOW to Install the Unit InstallationDimension of air conditioner Dimension of sleeve assembly optionalGeneral Wall Sleeve InstallationWall Case Installation Data As shipped, the LG wall sleeve is ready for installation Installation of Wall Case in Wall OpeningPreparation of the Front Grille Preparation of the Wall Case for All Types of ConstructionLGE Internal Use Only Sub-Base Connected Unit Installation Electrical Requirements Electrical SafetyElectrical Data for 230/208V Model 208, 230, and 208/230 Volt UnitsInstallation Field Installed AccessoriesControl Panel Key Lock DescriptionHazardous Voltage Condensate Disposal Pump Kit InstallationPart No AYSB2101 Place the top cover assembly back into the unit Spraying Architectural Grille Architecture Grille Aluminum Single PackPart No AYDR101 Drain InstallationCondensate Drain kit Outdoor Drain Kit Installation Outdoor Drain Kit InstallationChecklist Indoor Drain Kit InstallationLeveling Legs Part No AYLL101Leveling Leg Assembly Installation on Wall Sleeve Leveling Leg AssemblyJunction Box Kit Installation and Wiring Procedure Hard Wire KitPart No AYAGALA01 Use Copper Conductors OnlyVolt Units 208/230 Volt UnitsPart No AYRE110 Remote Escutcheon KitPart No AYSB1101 230/208V 20A AYSB2101 230/208V 30A SubbaseTo each installation instruction for that accessory After wiring is complete, mount covers a and F toSkirting Hole Location Right Cover Assembly Subbase with provided screws. FigureOutside Dimensions Troubleshooting GuidePiping System 066mm 406mm 505mmTroubleshooting Guide Fails to Start Complaint Cause Remedy 208/230V 187V 253V Room AIR Conditioner Voltage LimitsComplaint Cause Remedy Th2 Thermistor for Evaporator pipe temperature Piping DiagramsTh3 Thermistor for outdoor Air temperature Th4 Thermistor for Condenser pipe Air temperatureCN-NN Schematic Diagram435300B Exploded ViewJanuary