LG Electronics LP121HEM-Y8 manual Specification, LGE Internal Use Only

Page 2

1. Specification

 

Model

 

LP121HEM-Y8

 

Cooling Capacity

 

 

kW

3.28

 

3.37

 

 

 

Btu/h.

11300

 

11500

Heating Capacity ( for Heat Pump models)

 

kW

2.99

 

3.08

 

 

 

Btu/h.

10300

 

10500

Electric Heater capacity

 

 

kW

3.1

 

3.5

 

 

 

Btu/h.

10500

 

11900

Power Input

Cooling/Heating

 

W

1130 / 975

 

1150 / 995

Running Current

Cooling/Heating

 

A

5.6 / 4.8

 

5.2 / 4.4

Starting current

Cooling/Heating

 

A

-

 

-

Electric Heater Current

 

 

A

14.9

 

15.2

EER

 

 

W/W

2.84

 

2.84

 

 

 

Btu/h.W

10.0

 

10.0

COP

 

 

W/W

3.1

 

3.1

Power Supply

 

 

Ø / V / Hz

1 / 208 / 60

 

1 / 230 / 60

Power Factor

 

 

%

96.2/96.7

 

96.2/98.3

Air Flow Rate

Indoor,Max

 

m3/min(CFM)

11(390)

 

 

Outdoor,Max

 

m3/min(CFM)

-

 

 

Moisture Removal

 

 

l/h

1.5

 

Sound Level

Indoor,H/M/L

 

dB(A)±3

49/-/47

 

(SoundPressure,1m)

Outdoor,Max

 

dB(A)±3

63

 

Refrigerant & Charge

 

 

g(oz)

R22, 795(28.0)

 

Compressor

Type

 

Rotary(Non Tropical)

 

 

Model

 

QK164KBB

 

 

Motor Type

 

PSC

 

 

Oil Type

 

SUNISO 4GSI or NM56M

 

 

Oil Charge

 

cc

280

 

 

O.L.P Name

 

MRA 12124 - 12026

 

Fan

Type(In/Out)

 

Cross Flow Fan

 

Axial Fan

 

Motor Type(In/Out)

 

4 Poles

 

 

Motor Output(In/Out)

 

W

18.4/60

 

Power Supply Cable (Power Cord)

 

No.*mm2

3 * 2.1

 

Dimensions ( W * H * D)

 

 

mm

1066*406*505

 

 

 

 

inch

42*16*19-7/8

 

Net Weight

 

 

kg(lbs)

52.0(114.6)

 

Tool Code(Chassis)

 

 

 

YA

 

Features

Temperature Control

 

Thermistor

 

 

Energy Saver Mode

 

O

 

 

Prefilter(washable/anti-fungus)

 

O

 

 

Plasma Filter

 

-

 

 

 

Steps, Fan/Cool/Heat

 

2/2/2

 

 

Airflow Direction Control(up&down)

Manual

 

 

Airflow Direction Control(left&right)

-

 

 

 

Remote Controller Type

 

Wall Thermostat

 

 

Setting Temperature Range

 

Cooling

54˚F ~ 86˚F(12.2˚C ~ 30˚C)

 

 

 

 

Heating

54˚F ~ 86˚F(12.2˚C ~ 30˚C)

 

 

Auto Operation (Micom Control)

 

-

 

 

 

Panel Touch Type

 

Manual controls

 

 

Timer

 

-

 

 

 

Air Discharge

 

Rear

 

 

Air-Ventilation

 

O

 

 

Defrost Control

 

O

 

 

Hot Start

 

-

 

 

 

Look

 

L - Look

 

 

Cabinet Type(Chassis Type)

 

Slide In-Out

 

 

Special Function

 

Electric Heater

 

Note:

O : Applied, - : No relation

*For circuit breaker rating, please confirm to local standards wherever necessary. Some of functions are slightly different depending upon models.

The specification may be subject to change without prior notice for purpose of improvement.

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 2 -

Only for training and service purposes

LGE Internal Use Only

 

Image 2
Contents SVC Manual Specification LGE Internal Use OnlyFeatures and Benefits Sleeve and the Rear GrilleTemperature limits Door Switch/Occupancy SensorOutdoor Air Temperature Switchover Quick Heater RecoveryVentilation Control LocationsOperation Electric Heating Model Cooling only ModelRemoving the Front Grille Temperature LimitingAdditional Controls Additional ControlsEnergy Saver Molex Housing SpecREMOTE/LOCAL Control Front Desk ControlFront Grille Disassembly InstructionsMechanical Parts Control BOX AIR Handling Parts Electric Heater Electric Heater Model onlyCross Flow FAN Axial FANOutdoor Motor Electrical PartsShroud CompressorPower Cord 6 P.C.BEvaporator Refrigeration CycleCondenser Capillary TubeLGE Internal Use Only Pulling Vacuum Dimension of air conditioner InstallationHOW to Install the Unit Dimension of sleeve assembly optionalGeneral Wall Sleeve InstallationWall Case Installation Data Preparation of the Front Grille Installation of Wall Case in Wall OpeningAs shipped, the LG wall sleeve is ready for installation Preparation of the Wall Case for All Types of ConstructionLGE Internal Use Only Sub-Base Connected Unit Installation Electrical Data for 230/208V Model Electrical SafetyElectrical Requirements 208, 230, and 208/230 Volt UnitsControl Panel Key Lock Field Installed AccessoriesInstallation DescriptionHazardous Voltage Condensate Disposal Pump Kit InstallationPart No AYSB2101 Place the top cover assembly back into the unit Spraying Architecture Grille Aluminum Single Pack Architectural GrillePart No AYDR101 Drain InstallationCondensate Drain kit Outdoor Drain Kit Installation Outdoor Drain Kit InstallationLeveling Legs Indoor Drain Kit InstallationChecklist Part No AYLL101Leveling Leg Assembly Leveling Leg Assembly Installation on Wall SleevePart No AYAGALA01 Hard Wire KitJunction Box Kit Installation and Wiring Procedure Use Copper Conductors Only208/230 Volt Units Volt UnitsRemote Escutcheon Kit Part No AYRE110Subbase Part No AYSB1101 230/208V 20A AYSB2101 230/208V 30ASkirting Hole Location Right Cover Assembly After wiring is complete, mount covers a and F toTo each installation instruction for that accessory Subbase with provided screws. FigurePiping System Troubleshooting GuideOutside Dimensions 066mm 406mm 505mmTroubleshooting Guide Fails to Start Complaint Cause Remedy Room AIR Conditioner Voltage Limits 208/230V 187V 253VComplaint Cause Remedy Th3 Thermistor for outdoor Air temperature Piping DiagramsTh2 Thermistor for Evaporator pipe temperature Th4 Thermistor for Condenser pipe Air temperatureSchematic Diagram CN-NNExploded View 435300BJanuary