State Industries A B C D E F 100 instruction manual 197836-000

Page 1

Instruction Manual

RESIDENTIAL GAS WATER HEATERS

POWER VENT/POWER DIRECT VENT GAS MODELS

WITH HOT SURFACE IGNITION

www.statewaterheaters.com

For Your Safety

AN ODORANT IS ADDED TO THE GAS USED

BY THIS WATER HEATER.

ALL TECHNICAL AND WARRANTY QUESTIONS: SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS PURCHASED. IF YOU ARE UNSUCCESSFUL, CALL THE TECHNICAL SUPPORT PHONE NUMBER SHOWN ON THE WATER HEATER LABELING.

 

Keep this manual in the pocket on heater for future reference

 

whenever maintenance adjustment or service is required.

PRINTED IN THE U.S.A 0408

197836-000

Image 1
Contents 197836-000 Whenever maintenance adjustment or service is requiredImportant Definitions Safe INSTALLATION, USE and ServiceGeneral Safety General Safety Introduction Table of ContentsGET to Know Your Water Heater GAS Models Replacement Parts and Deliming ProductsRough-In-Dimensions Installation ConsiderationsRecovery capacity based on 96% thermal efficiency All models Maximum Supply Pressure 14 inches W.C .48kPaDirectly BELOW. Keep Clear of ALL Obstructions Water Piping Mixing Valve Usage Facts to Consider About the Location Combustion AIR and Ventilation Insulation BlanketsAppliances in Unconfined Spaces Appliances in Confined SpacesALL AIR from Outdoors See Figures 7, 8 ALL AIR from Inside Buildings SeeChemical Vapor Corrosion Installing the NEW Water HeaterWater Piping Closed Water SystemsValve and Pipe Insulation if supplied Temperature-Pressure Relief ValveGas Piping High Altitude InstallationsFilling the Water Heater Sediment Traps VentingVent Pipe Termination Canadian Power Vent Power VentVent Hoods MAY be Extremely HOT During Operation Canadian Direct Vent Direct VentPlanning the Vent System InstallationsCondensate Vent Terminal INSTALLATION, Sidewall Installation of Vent SystemSequence of INSTALLATIONS, a Direct Vent Terminal Installation ImportantVertical Vent Terminal Installation Installation SequenceVent Terminals Supplied with Heater Must be Used Installation of Vertical Vent System Installation of Vent SYSTEM, SidewallConcentric Vent Installation KIT ComponentsInstallation Procedure 1 Roof TERMINATION, see Figure C Safety ConsiderationsFigure F Procedure 2 Side Wall TERMINATION, see Figure FFigure g MULTI-CONCENTRIC Vent TerminationsVent Pipe Preparation Step E Step BStep F Step GBlocked Exhaust Switch Blower Prover SwitchBlocked Intake Switch ON/OFF SwitchPower Vent Wiring Schematic Figure Do not try to light the burner by hand ON/OFF SwitchWhat to do if YOU Smell GAS Do not TRY to Light the Burner by HandHI Limit Switch E.C.O Temperature RegulationOverview Using the Electronic ControllerAction Operating StatesDisplay Action Access to the Current Fault or Warning Fault and Warning ConditionsChanging the Display Units DisplayViewing Information About the Heater Viewing the Fault HistoryStart UP Conditions For Your InformationOperational Conditions Burner Cleaning Periodic MaintenanceVenting System Inspection Burner Operation and InspectionAnode ROD Inspection Temperature-Pressure Relief Valve OperationDraining Leakage Checkpoints ServiceProblems Troubleshooting GuidelinesPage Page Limited Warranty