SAFETY INSTRUCTIONS
TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY INSTRUCTIONS IN THE MANUAL AND ON THE PUMP.
DESCRIPTION and SPECIFICATIONS
The Models ICS, close coupled, and
DANGER
WARNING
CAUTION
This is a SAFETY ALERT SYMBOL. When you see this symbol on the pump or in the manual, look for one of the following signal words and be alert to the potential for personal injury or property damage.
Warns of hazards that WILL cause serious personal injury, death or major property damage.
Warns of hazards that CAN cause serious personal injury, death or major property damage.
Warns of hazards that CAN cause personal injury or property damage.
The pumps are of back pullout configuration, with NPT suction and discharge connections and have investment cast AISI Type 316 stainless steel casings, open impellers and seal housing. All pumps are equipped with
Close coupled units are equipped with
Close coupled units are available with single and three phase ODP, TEFC and explosion proof motors. Consult with your distributor/dealer for additional information.
NOTICE: INSPECT UNIT FOR DAMAGE AND
NOTICE: INDICATES SPECIAL INSTRUCTIONS WHICH ARE VERY IMPORTANT AND MUST BE FOLLOWED.
THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION AND OPERATION OF THIS UNIT. THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS PRIOR TO PERFORMING ANY WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.
REPORT ALL DAMAGE TO CARRIER
IMMEDIATELY.
MAXIMUM OPERATING LIMITS
Liquid Temperature:
212° F (100° C) – standard mechanical seal 250° F (120° C) – OPTIONAL mechanical seal
Operating Pressure: 175 PSI (1203 kPa)
Starts per Hour: 20, evenly distributed
Installation – General
WARNING
Hazardous voltage can shock, burn or cause death.
Install, ground and wire accord- ing to local and National Electrical Code Requirements.
Install an all leg disconnect switch near the pump.
Disconnect and lockout electrical power before installing or servicing the pump.
Electrical supply must match motor’s nameplate specifications. Incorrect voltage can cause fire, damage motor and void the warranty.
•Locate the pump as near to the liquid source as possible.
•If pump repriming capability is required, the pump suction MUST be below the source of the liquid level.
•Protect the pump and piping from freezing temperatures.
•Allow adequate space around the unit for service and ventilation.
Close Coupled Units
•Units may be installed horizontally, inclined or vertically.
WARNING | DO NOT MOUNT MOTOR BELOW | |
PUMP. FLUID LEAKAGE ONTO | ||
|
Single phase pump motors are equipped with an automatic thermal protector, which opens the motor’s electrical circuit when an overload condition exists. This can cause the pump to start unexpectedly.
Hazardous | MOTOR CAN CAUSE A SHOCK, | |
voltage | ||
BURN OR DEATH. | ||
|
•Unit foundation must be flat and substantial to avoid pipe strains when bolts are tightened. Use rubber mounts under motor to minimize noise and vibration.
•Tighten motor holddown bolts BEFORE connecting the suction and discharge piping.
Frame Mounted Units
•Place the baseplate upon the foundation and disconnect the coupling halves. DO NOT reconnect the coupling until the alignment procedures have been completed.
•It is recommended that the baseplate be grouted to a foundation with a solid footing, per Figure 1.