PLANNING— EXHAUST SYSTEMS … CONTINUED
DETERMINE VENTING SIZE AND DISTANCE:
It is recommended that the vent system be installed with a minimum of three (3’) of vertical rise above the appliance exhaust port.
Equivalent Vent Length (EVL) is the method of determining vent sizes and lengths, that takes into account the effect of different component parts on air flow.
STEP 1 To help you determine the correct size and/or run, simply fill in the chart below.
Pellet Venting | # of Elbows | Multiply by | Equivalent | Component |
Component | OR feet of Pipe |
| Feet | Equivalent |
|
|
|
|
|
90 Degree or Tee |
| X | 5 |
|
|
|
|
|
|
45 Degree |
| X | 3 |
|
|
|
|
|
|
Horizontal Pipe |
| X | 1 |
|
|
|
|
|
|
Vertical Pipe |
| X | .5 |
|
|
|
|
|
|
|
|
| Total Equivalent |
|
|
|
|
|
|
Step 2 | Ensure the Total Equivalent is or is | eet F | 30 |
|
|
|
|
|
|
| |
|
|
|
| 4 Inch Diameter Only | |||||||
| less than 30. |
| ni |
|
|
|
| ||||
|
|
| ht | 20 |
|
|
|
|
|
|
|
|
|
| gne |
|
|
|
|
|
|
| |
Step 3 | Use the Sizing Chart to determine |
|
|
|
|
|
|
|
| ||
| the proper venting size according to | Le | 10 | 3 or 4 Inch Diameter Pipe |
|
|
| ||||
| the Total Equivalent and the |
| pPi |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| ||
| Altitude above sea level. |
| t |
|
|
|
|
|
|
|
|
|
| ne |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |
NOTE: | In some cases it may be necessary | avl ui | 0 | 1 | 2 3 4 | 5 | 6 7 | 8 | 9 | 10 | |
| to contact Dansons Customer |
| qE |
|
| Altitude in Thousands of Feet |
|
| |||
| Service personal to determine |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| |
| acceptable venting | Maximum venting height is 33’. |
|
|
|
| 33’ | ||||
| configurations |
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| |
| and altitude adjustments | Maximum horizontal offset is 10’. |
|
|
|
|
|
Use the Equivalent Vent Length |
|
|
|
|
|
|
|
|
|
|
| 30’ | |||||||
|
|
|
|
|
|
|
|
|
|
| |||||||||
| Chart to determine proper |
|
|
|
|
|
|
|
|
|
|
|
| ||||||
| combination of component parts. |
|
|
|
|
|
|
|
|
|
|
|
| 25’ | |||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Vent must have a support | Use 4” Diameter “PL” Vent |
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
| |||||||||||||
| If venting outside of |
|
|
|
|
|
| ||||||||||||
| bracket every 5’ when on |
|
|
|
|
|
| ||||||||||||
| shaded area. |
|
|
|
|
|
| ||||||||||||
| the exterior wall. |
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| 20’ | ||||||
| Vent height and run must |
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
The diagram to the right will help to | Use 3” or 4” Diameter |
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
| ||||||||||||||
not exceed the distance | “PL” Vent, if venting in |
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
| ||||||||||||||
| shown in the |
|
|
|
|
|
|
|
|
|
|
| 15’ | ||||||
give you a visual reference. | shaded area. |
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
| ||||||||||||
region of chart. |
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
| To achieve optimum |
|
|
|
|
|
|
|
|
|
|
|
| 10’ | |||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
| performance, keep vent runs |
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
| as short as possible. |
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
| Especially on horizontal |
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
| installations. |
|
|
|
|
|
|
|
|
|
|
| 5’ | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 0’ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
| 0’ |
|
|
| 5’ | 10’ | ||||||||
|
|
|
|
|
| ||||||||||||||
|
|
|
|
|
| ||||||||||||||
|
|
|
|
| |||||||||||||||