Dansons Group IGB, FGB manual Mobile Home Installation, Ceiling and Roof Must be Maintained

Page 18

MOBILE HOME INSTALLATION

CAUTION: DO NOT INSTALL STOVE IN SLEEPING ROOM

THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR,

CEILING and ROOF MUST BE MAINTAINED!

Your Glow Boy appliance has been tested and listed for mobile home installation. It may be installed in a mobile home as a "Free Standing Stove" or a "Hearth Stove", see detailed install and clearance requirements in these sections as they imply there.

In addition to all previously detailed installation requirements, mobile home in-stallations must meet the following requirements in accordance with the Manufactured Home and Safety Standard (HUD) CFR 3280, Part 24:

Permanently bolt your stove to the floor, (A), figure 25.

Electrically ground your stove or the pedestal to the steel frame of the home. Use a number 8 gauge copper wire, (B), figure 25, or equivalent.

The stove must have a permanent outside air source with a ¼ inch screen over the inlet. Figure 26, (B, C & D)

For transportation all chimney/vent above the mobile home must be removed.

Chimney/PL Vent must be 3” or 4” PL Vent and must extend a minimum or 36” above the roofline of the mobile home and must be installed using a UL / ULC listed ceiling fire stop (J), figure 26, and rain cap (L), figure 26., when installing as a vertical run. See diagram below.

REFER TO THE VENTING DIAGRAMS IN THIS MANUAL FOR FURTHER EXHUAST CONFIGURATIONS.

INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.

A

Floor Pad

B

Combustion Air Intake

C

Fresh Air Duct

D

Fresh Air Hood

E

Stove Exhaust

F

Pipe Adapter

 

 

G

Clean Out Tee

H

Tee Support Bracket

I

Pipe

J

Firestop Spacer / Ceiling Support

K

Roof Flashing / Storm Collar

L

Rain Cap

HEARTH PAD

L

K

J

I

H

G

FLOOR

A BOLT(S)

B

C

D

 

 

B GROUND FRAME

WIRE

Figure 25

A

Figure 26

Note: When moving your mobile home, all exterior venting must be removed. Upon completion of relocation, all venting must be reinstalled, gas tight, and securely fastened.

Glow Boy Pellet & Biomass

www.glowboystoves.com

18

 

 

18

 

 

 

Image 18
Contents Toll Free Technical Support Glowboy 456 Dear Glow Boy Multi-Fuel / Pellet Stove Owner Friendly ReminderTable of Contents Safety Precautions Grounded surge-protection unit is recommendedDo not unplug the stove if you suspect a malfunction Safety Testing HOW Your Appliance Works Fuel ConsiderationsAutomatic Safety Features Dimensions SpecificationsHeating Specifications Electrical SpecificationsNecessary for your stove Planning & Installation Check ListPlacement is decided on EssentialVent Safety Precautions PLANNING-EXHAUST SystemsPellet Vent Type PLANNING- Exhaust Systems … Determine Venting Size and DistanceStep Pellet Vent Termination Figures 7 Vent Termination ClearancesThrough The Wall Kits Include Outside air is Required on ALL Mobile Home InstallationsPLANNING- Outside AIR Foot Package PART#PLANNING- Protection & Clearances Stove PlacementClearances Straight Installation Floor Protection RequirementsClearances Corner Installation Alcove InstallationPLANNING- Protection & Clearances . . . CON’T Hand Tools Power ToolsTools Required SuppliesINSTALLATION-FREESTANDING Through the WallMobile Home Installation Ceiling and Roof Must be MaintainedFreestanding Installation . . . CON’T Hearth Stove Existing RelineFreestanding Installation . . . C on ’ T Fireplace Insert InstallationFull Chimney Reline Direct Connection BUILT-IN Installation Top Clearance BUILT-IN Insert Installation . . . CON’TMinimum Framing Dimensions Back ClearanceOpening and Closing the Main Door Setting the AIR Inlet DamperOperating Instructions Seating the Burn GrateBasic Overview Fill the Hopper with FuelChoose Mode of Operation Operating in Manual Mode To StartManual Operation Thermostat On/Off Thermostat Low/High Operating in Thermostat High / LOW Cycle Flashing 3 To Start … con’t After Pushing the Start touch padTrim Pots Fine Tune Adjustments- Factory Settings Auger CycleOperating INSTRUCTION- Lighting Your Appliance OPERATION- Performance Enhancements Giving Your Appliance a TUNE-UPAsh Content Fuel SPECIFICATIONS-WOOD PelletsFuel Rate Setting… LengthFuel SPECIFICATIONS-SHELLED Corn Corn QualityDoor & Trim Cleaning MAINTENANCE-ROUTINE CleaningWindow Cleaning Every 2 -3 Days / WeeklyMAINTENANCE- Periodic Cleaning TON, Seasonal or BI-SEASONALExhaust Venting Check and Clean the Hopper Service Contracts Yearly MaintenanceTrouble Shooting Dansons Customer Service atGrate but will not start Cont…Fuel feeds into the burn Burn grate fills with fuelBurn grate. Window Fire burns with a yellowFlame. Fuel builds up Gets real dirty quicklyOptional Accessories Extended Warranty Limited WarrantyParts, Service and Returns Additional Dansons Products