Dansons Group IGB, FGB manual BUILT-IN Installation

Page 22

BUILT-IN INSTALLATION

CAUTION: DO NOT BLOCK ANY VENT OPENINGS

PELLET VENT MUST MAINTAIN A MINIMUM 3” CLEARANCE TO ANY COMBUSTIBLE.

(INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER).

DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY OTHER APPLIANCE OR STOVE.

DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.

THE APPLIANCE MUST BY PLACED ON A NON-COMBUSTIBLE SURFACE,

BOTH ON THE HEARTH AND WITHIN THE FRAMED AREA.

(REFER TO FLOOR PROTECTION REQUIREMENTS IN THIS MANUAL.)

The Glow Boy Series Inserts may be framed directly into a wall as either a horizontal or vertical vent installation. (see figure 27, 28).

The exhaust installation requirements are the same as for a freestanding stove. Refer to

“Installing Freestanding Stove” for information concerning installation and proper hook-up of the exhaust.

NOTE: Built-in Installations require: Enclosure Spacer Kit — #ACI-3HZ Horizontal Kit or ACI-3VL Vertical Kit

Shroud 1”

Shroud 1”

12 1/4”

10 3/4”

 

18 3/4”

 

24”

24 3/4” 24”

 

 

 

6 1/2”

 

 

 

Exhaust

3 ½”

 

+

 

+

7 3/4”

 

 

 

 

Air Inlet

 

8 1/4”

 

 

 

12 1/4”

 

10 3/4”

 

 

26”

 

 

 

 

24”

 

 

 

 

 

 

 

 

 

Adjustable

 

 

 

 

 

 

Hopper

19”

 

 

6 ½”

 

 

 

 

 

 

 

 

-

 

 

Exhaust

 

 

 

23”

 

 

 

 

 

 

+

 

 

 

 

3 ½”

 

 

 

 

+

7 3/4”

 

 

 

 

 

 

24”

 

 

 

Air Inlet

8 1/4”

 

 

 

 

 

 

Classic Step Top Insert / Built-In

Glow Boy Pellet & Biomass

Bay View Insert / Built-In

www.glowboystoves.com 2222

Image 22
Contents Toll Free Technical Support Glowboy 456 Dear Glow Boy Multi-Fuel / Pellet Stove Owner Friendly ReminderTable of Contents Grounded surge-protection unit is recommended Safety PrecautionsDo not unplug the stove if you suspect a malfunction Safety Testing HOW Your Appliance Works Fuel ConsiderationsAutomatic Safety Features Dimensions SpecificationsHeating Specifications Electrical SpecificationsNecessary for your stove Planning & Installation Check ListPlacement is decided on EssentialPLANNING-EXHAUST Systems Vent Safety PrecautionsPellet Vent Type Determine Venting Size and Distance PLANNING- Exhaust Systems …Step Pellet Vent Termination Figures 7 Vent Termination ClearancesThrough The Wall Kits Include Outside air is Required on ALL Mobile Home InstallationsPLANNING- Outside AIR Foot Package PART#PLANNING- Protection & Clearances Stove PlacementClearances Straight Installation Floor Protection RequirementsAlcove Installation Clearances Corner InstallationPLANNING- Protection & Clearances . . . CON’T Hand Tools Power ToolsTools Required SuppliesINSTALLATION-FREESTANDING Through the WallMobile Home Installation Ceiling and Roof Must be MaintainedFreestanding Installation . . . CON’T Hearth Stove Existing RelineFreestanding Installation . . . C on ’ T Fireplace Insert InstallationFull Chimney Reline Direct Connection BUILT-IN Installation Top Clearance BUILT-IN Insert Installation . . . CON’TMinimum Framing Dimensions Back ClearanceOpening and Closing the Main Door Setting the AIR Inlet DamperOperating Instructions Seating the Burn GrateBasic Overview Fill the Hopper with FuelOperating in Manual Mode To Start Choose Mode of OperationManual Operation Thermostat On/Off Thermostat Low/High Operating in Thermostat High / LOW Cycle Flashing 3 To Start … con’t After Pushing the Start touch padTrim Pots Fine Tune Adjustments- Factory Settings Auger CycleOperating INSTRUCTION- Lighting Your Appliance OPERATION- Performance Enhancements Giving Your Appliance a TUNE-UPAsh Content Fuel SPECIFICATIONS-WOOD PelletsFuel Rate Setting… LengthFuel SPECIFICATIONS-SHELLED Corn Corn QualityDoor & Trim Cleaning MAINTENANCE-ROUTINE CleaningWindow Cleaning Every 2 -3 Days / WeeklyTON, Seasonal or BI-SEASONAL MAINTENANCE- Periodic CleaningExhaust Venting Check and Clean the Hopper Service Contracts Yearly MaintenanceTrouble Shooting Dansons Customer Service atGrate but will not start Cont…Fuel feeds into the burn Burn grate fills with fuelBurn grate. Window Fire burns with a yellowFlame. Fuel builds up Gets real dirty quicklyOptional Accessories Extended Warranty Limited WarrantyParts, Service and Returns Additional Dansons Products