Dansons Group FGB, IGB MAINTENANCE-ROUTINE Cleaning, Every 2 -3 Days / Weekly, Window Cleaning

Page 33

MAINTENANCE—ROUTINE CLEANING

WARNING: Regular maintenance must be conducted for safe and efficient operation. Disconnect power to the stove if maintenance requires the opening of service panels. Conduct maintenance on a COLD appliance only.

Proper care of your Glow Boy SERIES pellet appliance is required for peak, sustained performance. The need for and frequency of cleaning depends on the amount of pellets burned, pellet quality, length of time since last cleaning and the quality of the fire. While becoming acquainted with your new stove and the types of local pellets, inspect your BURN GRATE, BURN POT, HEAT EXCHANGE, ASH PIT, and WINDOW daily and clean until a pattern of cleaning re-quirement is determined. As heating demands increase the need for stove and exhaust system cleaning and ash removal will increase.

EVERY 2 –3 DAYS / WEEKLY

CHECK BURN GRATE FOR CLINKERS: (B)

Heat Tubes

Hopper

If the flames seem to be coming only from the sides,

Tube Scraper

Auger

or are orange/black in color, turn the stove off and check

Window

Auger Motor

for build up in the grate.

 

Fan Motors

 

Burn Grate

The most likely causes are:

Exhaust

Burn Pot

Poor quality pellets, exhaust system requires cleaning

Air Intake

 

The air-inlet damper requires adjustment

 

Ash Pan

 

 

To Clean: (Cold Stove Only)

 

 

Open door, remove the burn grate, knock out any debris.

 

 

It may be necessary to scrape the holes clean.

B

 

Clean between the Burn Grate and Burn Pot as well.

 

BURN POT: (A) [COLD STOVE ONLY]

 

G

Remove the burn grate. Clean out the burn pot area of all debris.

CAUTION: When replacing the grate make sure it fits

 

 

properly in the burn pot.

C

 

WINDOW CLEANING:

[COLD STOVE ONLY as hot glass may cause serious burns] To enjoy a clear view of the fire you should clean your window as needed with a soft cloth or paper towel. You may use a Fireplace glass cleaner or vinegar water to remove heavy build up on the window.

Mirror cleaners and oven cleaners will leave a film on the glass and attract smoke like a magnate.

HOME TIP: Dampen a piece of newsprint with water, dip this into the fly ash, then rub down the glass. This works like a charm. Do not use abrasive chemical cleaners.

DO NOT OPERATE STOVE WITH BROKEN GLASS AS LEAKAGE OF FLUE GASES MAY RESULT.

DOOR & TRIM CLEANING:

Fingerprints or other marks left on gold surfaces may become etched in place, if they are not wiped clean prior to turning the stove on. Use a damp cloth to wipe clean.

DO NOT USE ABRASIVE CLEANERS AS YOU WILL REMOVE OR SCRATCH THE PLATING!

A

Glow Boy Pellet & Biomass

www.glowboystoves.com

33

 

 

33

 

 

 

Image 33
Contents Toll Free Technical Support Glowboy 456 Friendly Reminder Dear Glow Boy Multi-Fuel / Pellet Stove OwnerTable of Contents Safety Precautions Grounded surge-protection unit is recommendedDo not unplug the stove if you suspect a malfunction Safety Testing Fuel Considerations HOW Your Appliance WorksAutomatic Safety Features Heating Specifications SpecificationsDimensions Electrical SpecificationsPlacement is decided on Planning & Installation Check ListNecessary for your stove EssentialVent Safety Precautions PLANNING-EXHAUST SystemsPellet Vent Type PLANNING- Exhaust Systems … Determine Venting Size and DistanceStep Vent Termination Clearances Pellet Vent Termination Figures 7PLANNING- Outside AIR Outside air is Required on ALL Mobile Home InstallationsThrough The Wall Kits Include Foot Package PART#Clearances Straight Installation Stove PlacementPLANNING- Protection & Clearances Floor Protection RequirementsClearances Corner Installation Alcove InstallationPLANNING- Protection & Clearances . . . CON’T Tools Required Power ToolsHand Tools SuppliesThrough the Wall INSTALLATION-FREESTANDINGCeiling and Roof Must be Maintained Mobile Home InstallationHearth Stove Existing Reline Freestanding Installation . . . CON’TFireplace Insert Installation Freestanding Installation . . . C on ’ TFull Chimney Reline Direct Connection BUILT-IN Installation Minimum Framing Dimensions BUILT-IN Insert Installation . . . CON’TTop Clearance Back ClearanceOperating Instructions Setting the AIR Inlet DamperOpening and Closing the Main Door Seating the Burn GrateFill the Hopper with Fuel Basic OverviewChoose Mode of Operation Operating in Manual Mode To StartManual Operation Thermostat On/Off Thermostat Low/High To Start … con’t After Pushing the Start touch pad Operating in Thermostat High / LOW Cycle Flashing 3Auger Cycle Trim Pots Fine Tune Adjustments- Factory SettingsOperating INSTRUCTION- Lighting Your Appliance Giving Your Appliance a TUNE-UP OPERATION- Performance EnhancementsFuel Rate Setting… Fuel SPECIFICATIONS-WOOD PelletsAsh Content LengthCorn Quality Fuel SPECIFICATIONS-SHELLED CornWindow Cleaning MAINTENANCE-ROUTINE CleaningDoor & Trim Cleaning Every 2 -3 Days / WeeklyMAINTENANCE- Periodic Cleaning TON, Seasonal or BI-SEASONALExhaust Venting Check and Clean the Hopper Trouble Shooting Yearly MaintenanceService Contracts Dansons Customer Service atFuel feeds into the burn Cont…Grate but will not start Burn grate fills with fuelFlame. Fuel builds up Fire burns with a yellowBurn grate. Window Gets real dirty quicklyOptional Accessories Parts, Service and Returns Limited WarrantyExtended Warranty Additional Dansons Products