PLANNING— OUTSIDE AIR
Outside air is REQUIRED ON ALL MOBILE HOME INSTALLATIONS.
Outside air is strongly recommended for all other installations. Failure to install intake air may result in improper combustion as well as the unit smoking during power failures.
Metal pipe, ONLY, either solid or flexible, must be used in all outside air installations.(B) NOTE:
MUST NOT BE USED for outside air installations.
A wind shield, (C), over the termination of the outside air pipe or a 90 degree elbow or bend directed away from the prevailing winds MUST be used when an outside air pipe is
When outside air is taken from an existing chimney, the exhaust system must not terminate in the same chimney.
The outside air pipe on your stove is 2" OD. The outside air connecting pipe must be at least 2" ID The outside air connecting pipe must be as short and free of elbows as possible, and must fit over, (A), not inside, the outside air pipe on your stove.
For distances over 10’ long, 3” or 4” OD pipe is recommended, then reduce to 2”.
Through The Wall Kits Include:
3 FOOT PACKAGE – PART# | 10 FOOT PACKAGE – PART# |
1 – 2” Galvanized Hood c/w screen
1 – 2” Aluminum Flex Duct –
compressed 15” length, extends to 30” – 36” 2 – 2” Worm Gear Clamps
1 – 2” Galvanized Hood c/w screen
1 – 2” Aluminum Flex Duct – compressed 4’ length, extends to 120”
2 – 2” Worm Gear Clamps
NOTE: Available from your local Authorized Dealer or Dansons Inc.
Figure 11
Glow Boy Pellet & Biomass | www.glowboystoves.com | 13 |
|
| 13 |
|
|
|