3M RSS-214 manual General Safety Information, Intended Use

Page 4

GENERAL SAFETY INFORMATION

Intended Use

The 3MWIBGETHeat Stress Monitor RSS-214 is designed to measure environmental factors that can contribute to heat stress.

List of Warnings and Cautions within these User Instructions

WARNING

This monitor helps to measure certain environmental factors that can contribute to heat stress. Misuse may result in sickness or death. For proper use, see supervisor or User Instructions, or call 3M in U.S.A., 1-800-243-4630. In Canada, call Technical Service at 1-800-267-4414.

Each person using this equipment must read and understand the information in these User Instructions. Use of this equipment by untrained or unqualified persons, or use that is not in accordance with these User Instructions, may adversely affect product performance and result in sickness or death.

Use only for monitoring environmental factors which the sensors and instrument are designed to monitor. Failure to do so may adversely affect product performance and result in sickness or death. For proper use, see supervisor or User Instructions, or call 3M in U.S.A., 1-800-243-4630. In Canada, call Technical Service at 1-800-267-4414.

Each time the unit is turned on, it performs a self-test. If the self-test fails, or an error code is displayed, do not use. Doing so may adversely affect product performance and result in sickness or death.

The RSS-214DL RS 232 serial data output port must be used in a non-hazardous area only. Using the data output port is not an intrinsically safe operation. Failure to do so may result in sickness or death.

Never alter or modify this instrument. Substitution of components may impair intrinsic safety. Doing so may adversely affect product performance and result in sickness or death. Repair or replace parts only with the 3M components approved for this unit. Failure to do so may adversely affect product performance and result in sickness or death.

Battery must be replaced in a non-hazardous area only. Battery replacement is not an intrinsically safe operation. Use only approved battery. Failure to do so may result in sickness or death.

Only charge the instrument in non-hazardous areas using a 3M battery charger (AC adapter). Battery charging and operating with AC adapter is not an intrinsically safe operation. Do not attempt to charge alkaline batteries. Doing so may adversely affect product performance and result in sickness or death.

CAUTION

Do not twist sensors once inserted into the base unit. Doing so may damage the sensor or sensor connector. The wet bulb wick must remain wet during operation to help maintain the accuracy of the sensor.

Keep all connectors clean and dry. If a connector becomes wet, it must be thoroughly dried prior to instrument usage. Condition of the sensor receptacles may be tested by removing all sensors, turning the unit on and checking that all functions read 0.0 ± 0.3 °C or 32.0 ± 0.5 °F. If these are not the readings, do not use until the reason has been determined and corrected.

Do not expose dry bulb (DB) to temperatures above 65 °C (150 °F). This may damage the base unit. To monitor environments above 65 °C (150 °F), use a remote sensor set accessory and relocate the base unit to a cooler area.

Avoid the use of harsh cleaning materials, abrasives and other organic solvents. Such materials may permanently scratch the surfaces and damage the display window, labels, or monitor housing.

Observe proper polarity when inserting the battery. Polarity is marked on the inside of the battery compartment.

This instrument may contain a nickel metal hydride (NiMH) battery. Dispose of battery in accordance with local regulations.



Image 4
Contents Wibget Heat Stress Monitor RSS-214 Page Table of Contents General Safety Information Intended UseUSE Instructions and Limitations Specifications · Dry Bulb DB Ambient air temperature@ air speed = 180 fpm minimum Data Logger OptionalWbgt SetupOperating Instructions Dry Bulb Sensor Wet Bulb Sensor Downloading Data Record Number Time Downloading DataHhmm Battery MaintenanceCalibration Troubleshooting PRODUCTS, Accessories and PartsRemedy Important Notice WarrantyFor More Information Moniteur de stress thermique RSS-214 Wibget Table DES Matières Enregistrement DES Données optionnelUsage prévu Renseignements Généraux SUR LA SécuritéAvertissement Directives ET Limites D‘UTILISATION Capteur du réservoir humideSpécifications Journal de données optionnelInstallation Installation du capteurEmplacement et environnement Thermomètre globe mouillé WbgtAutodiagnostics O U T D B W B G T R H % L O Mode de surveillanceDirectives D‘UTILISATION Mise sous tension / hors tensionConfiguration et affichage du calendrier/de l’horloge Mode d’enregistrementTéléchargement DES Données 29.0 26.6 Tableau 1 sortie sur imprimante/écran typique Pile EntretienÉtalonnage PRODUITS, Accessoires ET Pièces DépannageRecours Avis Imporant GarantieRenseignements Supplémentaires Español Índice Uso Información General DE SeguridadPrecaución Sensor de globo Especificaciones Registrador de datos OptionalInstalación Instalación del sensorPreparación del bulbo húmedo PrecauciónInstrucciones DE Operación Encedido/ApagadoAuto-diagnóstico O U T D B W B G T R H % L O Modo de monitorInstalación y vista de calendario/reloj Registro DE Datos OpcionalModo de registro Registro de demanda Vista durante el registroSalida de registro de datos Descarga DE DatosDescarga de datos 29.0 26.6 Tabla 1 Salida típica de pantalla/impresiónBatería MantenimientoCalibración Localización DE Averías PRODUCTOS, Accesorios Y PartesRecurso GarantíaPara Mayores Informes Wibget RSS-214 Monitor de Sobrecarga Térmica Sumário Descarregando Dados DownloadingInformação Geral DE Segurança Indicação de UsoLista de Advertências e Precauções destas Instruções de Uso CuidadoInstruções E Limitações DE USO Sensor de Bulbo ÚmidoEspecificações Configuração Ibutg WbgtInstalação do Sensor Preparação do Bulbo ÚmidoPage Ajustando e Visualizando o Calendário/Relógio Registro DE Dados Data Logging OpcionalModo Registro Data Log Solicitando Registro Visualizando Durante o RegistroSaindo do Modo de Registro de Dados Data Logging Requisitos do Sistema29.0 26.6 Tabela 1 Saída Típica de Impressora/Tela Bateria ManutençãoCalibração Solução DE Problemas PRODUTOS, Acessórios E PeçasGarantia do Monitor DE Sobrecarga Térmica 3M Para Mais InformaçõesPara outros produtos 3M Linha AbertaPage Page Page Compagnie 3M Canada Occupational Health and Environmental Safety Division3M México S.A. de C.V

RSS-214 specifications

3M RSS-214 is a cutting-edge communication solution designed to improve emergency response and management in critical situations. As a part of the robust suite of public safety and emergency management products by 3M, the RSS-214 is engineered to meet the diverse needs of first responders, allowing for efficient and effective communication during emergencies.

One of the main features of the 3M RSS-214 is its advanced voice communication capabilities. This system supports high-definition audio, ensuring that every message is clear and intelligible, which is crucial in high-stress scenarios where miscommunication can lead to dire consequences. The device incorporates noise-cancellation technology that minimizes background sounds, allowing operators to focus solely on the critical messages being communicated.

Another significant technological feature of the RSS-214 is its integration with various other emergency management systems. This interoperability allows for seamless communication among different agencies, which is often a challenge in emergency response situations. By utilizing common protocols and standards, the RSS-214 ensures that first responders from various organizations can share information quickly and effectively.

The RSS-214 is also equipped with real-time data exchange capabilities, which means responders can access vital information, such as maps, deployment statuses, and resource inventories, simultaneously while communicating with each other. This access to real-time data not only enhances situational awareness but also enables informed decision-making under pressure.

Durability is a key characteristic of the 3M RSS-214, designed to withstand the rigors of harsh environments typically encountered during emergencies. The materials used in the construction of the device are resistant to impact and water, ensuring reliability when it matters most.

Furthermore, the user-friendly interface of the RSS-214 allows for quick navigation and operation, so first responders can focus on their primary tasks rather than getting bogged down with complex technology. The device is also lightweight and portable, making it easy to carry and deploy in various scenarios.

In summary, the 3M RSS-214 is a powerful communication tool that enhances the effectiveness of emergency response efforts. With its high-definition audio, integration capabilities, real-time data exchange, durability, and user-friendly design, the RSS-214 is an essential asset for first responders aiming to improve outcomes in critical situations.