3M RSS-214 manual Downloading Data

Page 9

Setting and Viewing Calendar/Clock

While turning power ON, hold SELECT button down until self-diagnostics is complete and the year is displayed (2000 is displayed as “00”). To adjust a parameter press VIEW, to enter a value press SELECT.

Once a parameter has been entered the next one is displayed sequentially, the sequence is: year, month, date, day of the week (1 = Sunday, 7 = Saturday), hour (24 hour clock), minutes. Seconds are set to zero if the clock is changed but not if the clock is only viewed. The clock runs continuously when the unit is off and has the same security and life expectancy as the data in the logger.

Log Mode

To enter Data Log Mode and save previous data logging sessions already in memory:

1.After turning the instrument on, press and hold VIEW, then press SELECT, then release both. The display will show “AP.” (APPEND).

2.To append (add) data to that already in memory, press SELECT again. The time interval from the previous data logging session will be displayed.

3.If desired, the time interval may be changed at this time by pressing VIEW (time base) to select a different time interval. Time intervals available are 0.5, 1.0, 2.0, 5.0, 6.0, 10.0, 20.0, and 30.0 minutes.

4.Press SELECT again to resume data logging without erasing any previous records stored in memory.

To enter Log Mode and erase all previous data logging sessions in memory:

1.Press and hold VIEW, then press SELECT, then release both. The display will show “AP.” (APPEND).

2.Choose a time interval by pressing VIEW (time base) until the desired time interval is displayed. Refer to step 3. above for available time intervals.

3.Press SELECT to begin data logging and erase all previous data logging sessions in memory.

Note: The WIBGET monitor resets itself to monitor mode when the memory is full.

Demand Logging

Pressing SELECT at any time during data logging will cause the immediate addition in memory of a data set other than those data sets logged at the preselected time interval. This feature is useful if an unusual event occurs at a time other than at the preselected time intervals. As an example, if data logging is occurring at 30 minute time intervals, and an unusual event occurs 14 minutes after the last 30 minute logging, pressing SELECT will capture that event in memory 14 minutes after the last 30 minute logging has occurred without affecting the pre selected 30 minute time interval.

To perform Demand Data Logging only:

1.Press and hold VIEW, then press SELECT, then release both. The display will show “AP.” (APPEND).

2.Press View until the display shows “.0”.

3.Pressing SELECT at any time will immediately add a data set in memory with time noted. Since no time interval has been selected, data logging occurs only when SELECT is pressed.

View While Logging

To view function while data logging press and hold VIEW to observe a current FUNCTION (OUT WBGT, WB, DB, etc.). By releasing and pressing VIEW, each FUNCTION may be observed.

Exit Data Logging

Simply turn off power to the WIBGET with the ON/OFF switch. Any data in memory will remain stored in memory.

Exit Data Logging Mode and Return to Monitor Mode

Press and hold VIEW, press SELECT, then release both. The display will now be in monitor mode showing OUT WBGT on the display. Alternately pressing and releasing VIEW will display each FUNCTION (OUT WBGT, WB, DB, etc.) in turn.

DOWNLOADING DATA

System Requirements

The following minimum system requirements are necessary to install, set up, and operate the 3MWIBGETHeat Stress Monitor software program: PC or laptop running

Windows 98, 2000 or XP with available RS-232 Com Port. Note: A DB-9 to DB-25 adapter may be needed to connect the RS-232 cable to the computer’s serial port.

Installing WIBGET Heat Stress Monitor Software

1.Exit all programs currently running in Windows.

2.Insert the WIBGET Heat Stress Monitor Software CD into the PC or laptop CD ROM drive.

3.In Microsoft Explorer (or My Computer), double click on your CD drive (often drive D:) and locate the Setup.exe file.

4.Double click on the Setup.exe file or icon to begin the installation.

5.Follow instructions on the menu screens to initialize the WIBGET Heat Stress Monitor Software program. It is recommended that you retain the default folders and file names.

Image 9
Contents Wibget Heat Stress Monitor RSS-214 Page Table of Contents Intended Use General Safety InformationUSE Instructions and Limitations · Dry Bulb DB Ambient air temperature Specifications@ air speed = 180 fpm minimum Data Logger OptionalSetup WbgtOperating Instructions Dry Bulb Sensor Wet Bulb Sensor Downloading Data Downloading Data Record Number TimeHhmm Maintenance BatteryCalibration PRODUCTS, Accessories and Parts TroubleshootingImportant Notice Warranty RemedyFor More Information Moniteur de stress thermique RSS-214 Wibget Enregistrement DES Données optionnel Table DES MatièresRenseignements Généraux SUR LA Sécurité Usage prévuAvertissement Capteur du réservoir humide Directives ET Limites D‘UTILISATIONJournal de données optionnel SpécificationsInstallation du capteur InstallationEmplacement et environnement Thermomètre globe mouillé WbgtO U T D B W B G T R H % L O Mode de surveillance AutodiagnosticsDirectives D‘UTILISATION Mise sous tension / hors tensionMode d’enregistrement Configuration et affichage du calendrier/de l’horlogeTéléchargement DES Données 29.0 26.6 Tableau 1 sortie sur imprimante/écran typique Entretien PileÉtalonnage Dépannage PRODUITS, Accessoires ET PiècesAvis Imporant Garantie RecoursRenseignements Supplémentaires Español Índice Información General DE Seguridad UsoPrecaución Sensor de globo Registrador de datos Optional EspecificacionesInstalación del sensor InstalaciónPreparación del bulbo húmedo PrecauciónEncedido/Apagado Instrucciones DE OperaciónAuto-diagnóstico O U T D B W B G T R H % L O Modo de monitorRegistro DE Datos Opcional Instalación y vista de calendario/relojModo de registro Vista durante el registro Registro de demandaSalida de registro de datos Descarga DE Datos29.0 26.6 Tabla 1 Salida típica de pantalla/impresión Descarga de datosMantenimiento BateríaCalibración PRODUCTOS, Accesorios Y Partes Localización DE AveríasGarantía RecursoPara Mayores Informes Wibget RSS-214 Monitor de Sobrecarga Térmica Descarregando Dados Downloading SumárioIndicação de Uso Informação Geral DE SegurançaLista de Advertências e Precauções destas Instruções de Uso CuidadoSensor de Bulbo Úmido Instruções E Limitações DE USOEspecificações Ibutg Wbgt ConfiguraçãoInstalação do Sensor Preparação do Bulbo ÚmidoPage Registro DE Dados Data Logging Opcional Ajustando e Visualizando o Calendário/RelógioModo Registro Data Log Visualizando Durante o Registro Solicitando RegistroSaindo do Modo de Registro de Dados Data Logging Requisitos do Sistema29.0 26.6 Tabela 1 Saída Típica de Impressora/Tela Manutenção BateriaCalibração PRODUTOS, Acessórios E Peças Solução DE ProblemasPara Mais Informações Garantia do Monitor DE Sobrecarga Térmica 3MPara outros produtos 3M Linha AbertaPage Page Page Occupational Health and Environmental Safety Division Compagnie 3M Canada3M México S.A. de C.V

RSS-214 specifications

3M RSS-214 is a cutting-edge communication solution designed to improve emergency response and management in critical situations. As a part of the robust suite of public safety and emergency management products by 3M, the RSS-214 is engineered to meet the diverse needs of first responders, allowing for efficient and effective communication during emergencies.

One of the main features of the 3M RSS-214 is its advanced voice communication capabilities. This system supports high-definition audio, ensuring that every message is clear and intelligible, which is crucial in high-stress scenarios where miscommunication can lead to dire consequences. The device incorporates noise-cancellation technology that minimizes background sounds, allowing operators to focus solely on the critical messages being communicated.

Another significant technological feature of the RSS-214 is its integration with various other emergency management systems. This interoperability allows for seamless communication among different agencies, which is often a challenge in emergency response situations. By utilizing common protocols and standards, the RSS-214 ensures that first responders from various organizations can share information quickly and effectively.

The RSS-214 is also equipped with real-time data exchange capabilities, which means responders can access vital information, such as maps, deployment statuses, and resource inventories, simultaneously while communicating with each other. This access to real-time data not only enhances situational awareness but also enables informed decision-making under pressure.

Durability is a key characteristic of the 3M RSS-214, designed to withstand the rigors of harsh environments typically encountered during emergencies. The materials used in the construction of the device are resistant to impact and water, ensuring reliability when it matters most.

Furthermore, the user-friendly interface of the RSS-214 allows for quick navigation and operation, so first responders can focus on their primary tasks rather than getting bogged down with complex technology. The device is also lightweight and portable, making it easy to carry and deploy in various scenarios.

In summary, the 3M RSS-214 is a powerful communication tool that enhances the effectiveness of emergency response efforts. With its high-definition audio, integration capabilities, real-time data exchange, durability, and user-friendly design, the RSS-214 is an essential asset for first responders aiming to improve outcomes in critical situations.