Bradford-White Corp D)W275T*(BN, CX Service Procedure AG-III, Gas Control Testing and Replacement

Page 12

SERVICE PROCEDURE AG-III

Gas Control Testing and Replacement

For Models using White Rodgers or

Robertshaw Gas Control

Gas Control Testing and Replacement

The gas control is a non repairable device. If trouble shooting has determined a problem with the gas control, it must be replaced.

If the burner and/or pilot do not function, service checks for gas pressure, thermocouple output, magnet assembly and ECO are to be performed. If these check OK, the gas control may be faulty.

LINE PRESSURE

The gas control is designed for a maximum line pressure of 14.0" w.c. and a minimum line pressure of 1.0"w.c. over the water heater rated manifold pressure. Line pressure must be checked with burner on and burner off to assure proper readings.

MANIFOLD PRESSURE TESTING (this procedure assumes a maximum line pressure of 14.0" w.c.)

Step 1. Set gas control to “OFF” position.

Step 2. Remove pressure tap plug and install pressure tap.

Step 3. Connect manometer to pressure tap.

Step 4. Follow lighting instructions and proceed to light main burner and observe manometer reading.

Step 5. Proper operating range for natural gas is 4.0 ±0.3" W.C. Proper operating range for L.P. gas is 10.0 ±0.5" W.C.

Figure 16

Pressure Tap

Shown

Installed

Step 6. If pressure is OK, set gas control to “OFF”Figure 17 remove manometer and pressure tap and replace pressure tap plug. Check for gas leaks before placing water heater back in operation. If pressure is out of the specification noted in step 5, proceed to step 7 or 8 for proper service procedure.

Step 7. For White Rodgers control, the manifold pressure is not adjustable. If manifold pressure is outside the range in step 5, the control must be replaced.

Step 8. For Robertshaw control, the manifold pressure is adjustable, proceed to step 9 for adjustment procedure

Step 9. While burner is in operation, remove regulator access cap to expose the regulator adjusting screw. With small screw driver, rotate adjusting screw clockwise to increase pressure and counter clockwise to decrease pressure.

Figure 18

 

Figure 19

Step 10. Replace regulator access cap, set gas control to “OFF”. Remove manometer and

pressure tap and replace pressure tap plug. Check for gas leaks before placing water heater back in operation.

Page 12

12

Image 12
Contents Service Manual Table of Contents Troubleshooting Chart LED Status Control Status Probable Cause LED Status Control Status Probable Cause Service Procedure Service Procedure AG-I Open Circuit Thermocouple TestingThermocouple Replacement Open Circuit Thermopile Testing Closed Circuit Thermopile TestingAn Open Circuit test A Closed Circuit testThermopile Replacement Step Turn off gas supply to water heater. Rotate knob Pilot Assembly Inspection Cleaning and Replacement IGNITER/ELECTRODE Testing Replacement Service Procedure AG-III Gas Control Testing and ReplacementLine Pressure Thermocouple Testing Magnet Assembly Testing White Rodgers ControlMagnet Assembly Testing Robertshaw Control ECO Energy Cut Off Testing GAS Control ReplacementInstallation of gas control Honeywell Thermowell Testing Determine Water Heater Tank Temperature Honeywell GAS Control & Thermowell Removal Honeywell GAS Control Removal from ThermowellHoneywell GAS Control Assembly to Thermalwell Service Procedure AG-IV Cast Iron Burner AdjustmentBurner Cleaning Steel & Cast Iron Burner Cleaning Service Procedure AG-V Diptube Inspection and ReplacementAnode Inspection and Replacement Turn gas control knob to OFF positionPage Page