SERVICE PROCEDURE AG-IV

Burner Operation Inspection, Adjustment

Cleaning and Replacement

BURNER CLEANING (Cont.)

Step 5. Steel Burner:

Disconnect (unscrew) burner from main burner orifice.

Cast Iron Burner:

Disconnect (unscrew) main burner feedline from burner.

Figure 44

Step 6. Remove main burner orifice from feedline.

Inspect and clean if necessary.

Step 7.

Inspect pilot assembly per service procedure AG-II.

Figure 45

Step 8. Reassemble burner assembly.

Step 9. Inspect combustion chamber area of water heater and clean if needed prior to reinstallation of burner assembly.

Step 10. Reinstall burner assembly into combustion chamber, reconnect feedline, thermocouple or thermopile, pilot tube and igniter wire (for applicable models) to the gas control.

Step 11. Slide close or attach inner combustion chamber door and reattach outer jacket door.

Step 12. To resume operation, follow the instructions located on the lighting instruction label or the lighting instructions located in the installation and operation manual.

Page 22

22

Image 22
Contents Service Manual Table of Contents Troubleshooting Chart LED Status Control Status Probable Cause LED Status Control Status Probable Cause Service Procedure Open Circuit Thermocouple Testing Service Procedure AG-IThermocouple Replacement An Open Circuit test Open Circuit Thermopile TestingClosed Circuit Thermopile Testing A Closed Circuit testThermopile Replacement Step Turn off gas supply to water heater. Rotate knob Pilot Assembly Inspection Cleaning and Replacement IGNITER/ELECTRODE Testing Replacement Gas Control Testing and Replacement Service Procedure AG-IIILine Pressure Magnet Assembly Testing White Rodgers Control Thermocouple TestingMagnet Assembly Testing Robertshaw Control ECO Energy Cut Off Testing GAS Control ReplacementInstallation of gas control Honeywell Thermowell Testing Determine Water Heater Tank Temperature Honeywell GAS Control & Thermowell Removal Honeywell GAS Control Removal from ThermowellHoneywell GAS Control Assembly to Thermalwell Service Procedure AG-IV Cast Iron Burner AdjustmentBurner Cleaning Steel & Cast Iron Burner Cleaning Service Procedure AG-V Diptube Inspection and ReplacementAnode Inspection and Replacement Turn gas control knob to OFF positionPage Page