This unit can be vented using only PVC (Class 160, ASTM D-2241 Schedule 40, ASTM D-1785; or Cellular Core Schedule 40 DWV, ASTM F-891), Schedule 40 CPVC (ASTM F-411), or ABS (ASTM D-2661) pipe. The fittings, other than the TERMINATIONS should be equivalent to PVC - DWV fittings meeting ASTM F-2665. (Use CPVC fittings, ASTM F-438 for CPVC pipe and ABS fittings, ASTM D-266/3311 for ABS pipe.) If CPVC or ABS pipe and fittings are used, then the proper cement must be used for all joints, including joining the pipe to the Termination (PVC material). PVC materials should use ASTM –D2564 grade cement; CPVC materials should use ASTM F-493 grade cement; and ABS materials should use ASTM D-2235 grade cement.

For water heaters in locations with high ambient temperatures (above 100°F) and/or insufficient dilution air, it is recommended that CPVC or ABS pipe and fittings (MUST USE SUPPLIED VENT TERMINAL) be used.

Horizontal Installation:

In a horizontal application, it is important that condensate not be allowed to buildup in the exhaust vent pipe. To prevent this from happening the pipe should be installed with an slight upward slope so the condensate will run back toward the water heater. The vent system should be supported every 5 feet of vertical run and every 3 feet of horizontal run of vent pipe length.

Stress levels in the pipe and fittings can be significantly increased by improper installation. If rigid pipe clamps are used to hold the pipe in place, or if the pipe cannot move freely through a wall penetration, the pipe may be directly stressed, or high thermal stresses may be formed when the pipe heats up and expands. Install accordingly to minimize such stresses.

Follow the following procedure to vent through the wall:

1.Cut two 3 1/2 in. (8.9 cm) diameter holes (for 3” (7.6 cm) diameter pipe) or 4 ½” (11.4 cm) diameter holes (for 4” (10.2 cm) diameter pipe) in the wall with the centerline hole distances at least 18” (45.72 cm) apart in the location where the exhaust vent and air intake terminals will exit the outside wall if vented on the same wall.

2.Use the proper PVC cement to secure the 90° exhaust vent and air intake terminals provided with the water heater to the plastic pipes. The distance between the back edge of the 90° exhaust vent terminal and the exterior wall (see Figure 13) must be 6 inches (12.7 cm) more for the exhaust vent terminal than the air intake terminal. Use the proper cement or sealant and assembly procedures to secure the vent connector joints between the terminal and the blower outlet. Provide support brackets for every 3 feet (.91 m) of horizontal vent.

21

Image 21
Contents What to do if YOU Smell GAS With Troubleshooting GuideTable of Contents Page Do not Operate the Appliance Until the Leakage is Corrected If YOU Smell GASSection SpecificationsSection III General Information FeaturesTemperature and Pressure Relief Valve Condensate Elbow With Loop Dishwashing Machine RequirementsSection IV Installation Instructions Minimum Clearance To Combustible UnpackingLocation Remove CrateAIR Requ Rements Unconfined Space Mechanical Exhausting of Room AIRConfined Space Chemical Vapor CorrosionTypical Front Inlet Connection Typical Installation IllustrationTypical Two Water Heater Connection Instructions for Connections Section V Water ConnectionsScalding Approximate TIME/TEMPERATURE Relationships in ScaldsAlternate Space Heating Connections Alternate Space Heating Water Connections Section VI Venting Typical Plumbing Schematic for Zoned HeatingVenting Direct Vent InstallationExceptions for Installations Page Typical Horizontal Direct Vent System Typical Vertical Direct Vent System Installation Direct Vent Maximum Vent Length Power Vent InstallationTypical Horizontal Power Vent System Typical Vertical Power Vent System Installation Coaxial Venting Installation Procedure Power Vent Maximum Vent LengthDimensional Layout of Concentric Vent Kit Concentric Vent Roof Top Attachment Initial Preparation Vent Pipe PreparationSelection of Materials Section VII GAS ConnectionsGAS Pressure Regulation GAS Meter Size Natural Gases onlySection Viii Electrical Connections Wiring Diagram and SchematicGeneral Instructions Section IX Operating InstructionsTo Fill the Water Heater Sequence of OperationLighting Instructions Temperature Adjustm NTSight Glass Location Burner Flame CheckSection X Maintenance Maintenance ScheduleGeneral Draining Water Heater Flushing Water HeaterFilling Water Heater Sediment and Lime Scale RemovalAnode Inspection and Replacement Drain Valve and Tank Access PanelRelief Valve Combustion System Inspection Vent and AIR Intake SystemReference Section XI Troubleshooting GuideIs there continuity across the Hot Surface Ignitor? If EF Series Water Heater Section XI Parts ListCombustion Surround Assy CC Ignition Control Assy