Bradford-White Corp U4TW60T*FRN, U4TW50T*FRN Pilot Inspection, Testing and Replacement cont’d

Page 23

Pilot Maintenance

Pilot Inspection, Testing and Replacement (cont’d)

Step 2.

Unplug the water heater

TTW (water heater)

from the wall outlet.

power cord

Step 3.

Turn off the gas supply to the water heater.

Step 4.

Remove the outer door.

Outer Door

Step 5. Remove the (4) 1/4” hex drive screws holding the right side inner door in place.

(4) 1/4” hex drive

screws

Step 6. Disconnect the pilot tube using a 7/16” wrench and the main burner feedline with a 3/4” wrench from the gas control.

 

 

Pilot and main

 

 

feedlines

Step 7.

Disconnect the spark igniter/flame sensor

wire from gas control.

Gas control

Spark igniter/flame

sensor wire

Right side inner door

Page 23

23

Image 23
Contents Service Manual Table of Contents Page Page Introduction Bradford White ECO-DEFENDER Safety SystemHow the Safety System Works How to Use this ManualTools Required Tools Required for ServiceSpecifications Gallon Vent TablesSpecifications Control Timings Wiring DiagramNormal Heating Sequence Power Up SequenceSequence of Operation Abnormal Operation Normal Heating Sequence cont’dAbnormal Operation cont’d Sequence of Operation Sequence of Operation LED Status Control Status Probable Cause Service Procedure TroubleshootingTroubleshooting Troubleshooting Burner Inspection Burner MaintenanceBurner Cleaning Procedure Burner Cleaning Procedure cont’d Pilot Inspection, Testing and Replacement Pilot MaintenancePilot Inspection, Testing and Replacement cont’d Page Pressure Switch Testing Pressure Switch TestingPressure Switch Testing cont’d Pressure Switch Replacement Pressure Switch ReplacementBlower Testing Blower TestingPage Blower Removal Blower ReplacementBlower Installation Blower Temperature Switch Testing Blower Temperature Switch TestingBlower Installation cont’d Switch Setting Blower Temperature Switch Testing cont’dBlower Temperature Switch Replacement Blower Temperature Switch ReplacementThermal Well Testing Thermal Well TestingDetermine Water Temperature Inside Tank Determine Tank TemperatureThermal Well Testing cont’d Gas Control & Thermal Well Removal From Water Heater Component DisassemblySensor Resistance at Various Temperatures Gas Control Removal Gas Control Removal From Thermal Well cont’d Gas Control AssemblyGas Control Assembly to the Thermal Well Gas Control Assembly to the Thermal Well cont’d Flammable Vapor Sensor Testing Flammable Vapor Sensor TestingVAC Circuit Trace Safety Circuit Voltage Trace Safety Circuit Voltage TraceBlower Removal Remove the Blower to Gain Access to the Flue BaffleDip Tube Inspection Remove the Blower to Gain Access to the Flue Baffle cont’dDip Tube Inspection and Replacement Anode Inspection Anode Inspection and ReplacementInner Door Removal Inner Door Removal ProcedureInner Door Gasket Replacement Procedure Inner Door Gasket ReplacementInner Door Removal Procedure cont’d Inner Door Installation with Gasket Inner Door InstallationScreenLok Flame Arrestor Cleaning Procedure Arrestor CleaningCommon Terms Common TermsPart Name and Description Parts ListParts@bradfordwhite.com Techserv@bradfordwhite.com