Bradford-White Corp U4TW60T*FRN, U4TW50T*FRN, U4TW40T*FRN Pressure Switch Testing cont’d

Page 26

Pressure Switch Testing

Pressure Switch Testing (cont’d)

Pressure switch

With steps 1,2 & 3 complete, discon- nect wire leads from pressure switch.

wire leads

Use a multi-meter

set to the ohms

setting. With

blower off, check across the pres- sure switch termi- nals. Are the switch contacts open (no electrical continuity)?

Y

Position the gas

control power

switch to the “ON” position and adjust the thermostat to call for heat. This will start the blower. Check with the multi-meter. Do the pressure switch contacts close with the blower running?

Y

The switch contacts are OK. See safety circuit trace (page 40).

N

Check the tubing and

N

pressure tap on switch

Replace switch

 

 

for blockage. Is there

(see page 27).

 

a blockage?

 

 

Y

Clear blockage

 

 

 

 

 

Y

Check the tub-

 

N ing and pressure N

Is the vent

tap on switch for

system

blockage. Is

blocked?

there a block-

 

age?

N

 

 

 

Y

Is vent system

 

length within the Y

See blower

vent table specifi-

testing (page

cations listed on

28). Is the

pages 9 & 10?

Blower OK?

N

N

 

Reconfigure vent

Correct the

system to be

blower prob-

compliant with

lem.

vent tables.

 

Page 26

26

Image 26
Contents Service Manual Table of Contents Page Page Bradford White ECO-DEFENDER Safety System IntroductionHow to Use this Manual How the Safety System WorksTools Required for Service Tools RequiredSpecifications Vent Tables GallonSpecifications Wiring Diagram Control TimingsNormal Heating Sequence Power Up SequenceSequence of Operation Normal Heating Sequence cont’d Abnormal OperationAbnormal Operation cont’d Sequence of Operation Sequence of Operation Troubleshooting LED Status Control Status Probable Cause Service ProcedureTroubleshooting Troubleshooting Burner Inspection Burner MaintenanceBurner Cleaning Procedure Burner Cleaning Procedure cont’d Pilot Maintenance Pilot Inspection, Testing and ReplacementPilot Inspection, Testing and Replacement cont’d Page Pressure Switch Testing Pressure Switch TestingPressure Switch Testing cont’d Pressure Switch Replacement Pressure Switch ReplacementBlower Testing Blower TestingPage Blower Removal Blower ReplacementBlower Installation Blower Temperature Switch Testing Blower Temperature Switch TestingBlower Installation cont’d Blower Temperature Switch Testing cont’d Switch SettingBlower Temperature Switch Replacement Blower Temperature Switch ReplacementThermal Well Testing Thermal Well TestingDetermine Water Temperature Inside Tank Determine Tank TemperatureThermal Well Testing cont’d Gas Control & Thermal Well Removal From Water Heater Component DisassemblySensor Resistance at Various Temperatures Gas Control Removal Gas Control Removal From Thermal Well cont’d Gas Control AssemblyGas Control Assembly to the Thermal Well Gas Control Assembly to the Thermal Well cont’d Flammable Vapor Sensor Testing Flammable Vapor Sensor TestingVAC Circuit Trace Safety Circuit Voltage Trace Safety Circuit Voltage TraceRemove the Blower to Gain Access to the Flue Baffle Blower RemovalDip Tube Inspection Remove the Blower to Gain Access to the Flue Baffle cont’dDip Tube Inspection and Replacement Anode Inspection and Replacement Anode InspectionInner Door Removal Procedure Inner Door RemovalInner Door Gasket Replacement Procedure Inner Door Gasket ReplacementInner Door Removal Procedure cont’d Inner Door Installation Inner Door Installation with GasketArrestor Cleaning ScreenLok Flame Arrestor Cleaning ProcedureCommon Terms Common TermsParts List Part Name and DescriptionParts@bradfordwhite.com Techserv@bradfordwhite.com