Bradford-White Corp TGHE-160I-N(X), TGHE-1991-N(X) instruction manual State Regulations

Page 12

State Regulations

NOTICE BEFORE INSTALLATION

Bradford White direct-vent appliance must be installed by a state qualified or licensed contractor. If you are not properly trained, you must not install this unit.

IMPORTANT: In the State of Massachusetts (248CMR 4.00 & 5.00)

For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of venting, including but not limited to decks and porches, the following requirements must be satisfied:

1.INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gas fitter must observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter must observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors. It is the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors.

a.In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

b.In the event that the requirements of this subdivision cannot be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm must be installed.

2.APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

3.SIGNAGE. A metal or plastic identification plate must be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign must read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.

4.INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5308(2)(a)1 through 4.

12

Image 12
Contents TGHE-160I-NX & TGHE-199I-NX Table of Contents Page Page If YOU Smell GAS Section II Specifications ModelDimensions Pressure Drop psi Water Flow Rate gpm Section III Installation Instructions Unpacking Water Heater LocationRemove Carton Mount Water Heater on the Wall State Regulations Important In the State of Massachusetts 248CMR 4.00Section IV Water Connections Water QualityInstructions for Connections Page Approximate TIME/TEMPERATURE Relationships in Scalds Recommended Piping for a Basic Installation Recommended Piping for a Circulation Systems Recommended Piping for Power Failure Freeze Protection Recommended Piping for Freeze ProtectionPressure Relief Valve Page Page Section V Venting Venting Vent / Air Intake Terminal Locations Direct Vent Terminal LocationVenting System Installation Venting System LayoutPrior to the Installation of the EverHot Direct Vent System Horizontal Direct Vent InstallationsIllustration Showing a Horizontal Termination Installation Vertical Direct Vent Installations Vertical Vent InstallationsCombustion Blower Dip Switch Settings Dip SwitchInstallation of Venting System Components Condensate Recommended Vent/Air Intake Terminal PositionJoint Connection Coping with CondensationIllustration Showing How to Shorten Vent Extensions Shortening of Vent ExtensionsVenting Parts & Dimensions Components Needed for Direct Vent ApplicationsVent Pipe Clamp, p/n Page Measure Dimension to Fit Illustration Showing How to Properly Cut a Vent ExtensionFinal Installation of the Vent System Illustration Showing How to Cut the Vertical Vent to Fit Cut the Vent to FitHigh Altitude Installations Mounting the Vent System Vertical DischargePage Venting Suppliers Manufacturer ProductSection VI GAS Connections GAS Meter Size Natural GAS only GAS Pressure RegulationGas Specific CorrectionInitial Operation and Testing Installer only Section VII Electrical Connections Ladder Diagram Wiring Diagram for Tghe Models Temperature Controls Page Securing screw Wiring hole 21/32 Installation of Remote Controls OptionalIllustration Showing Where to Connect Remote Control Harness Initial Operation and Testing of Controls Installer only Troubleshooting ElectricalResistance Connector Pin Nos Wire ColorHeat Exchanger and Outgoing Water Temperature Thermistors Flame RodFrost Protection Amp FusesSection Viii Operating Instructions General Instructions To Fill the Water HeaterSequence of Operation Lighting Instructions For Your Safety Read Before Operating Property damage, personal injury or loss of lifeWhat to do if YOU Smell GAS Operation InstructionsTemperature Adjustment Turning OFF the Water Heater for AN Extended Period of TimePage Approximate TIME/TEMPERATURE Relationships in Scalds ScaldingFirst AID for Scalds Code Code DescriptionCode Code Description Thermal Fuse Code Code Description Nothing happens Section IX Maintenance Burner Flame AppearancePage Circulating Pump Water HeaterPage Section X Parts List TGHE-160I TGHE-199I Description QuantityPage TGHE-160I TGHE-199I Page TGHE-160I TGHE-199I Page TGHE-160I TGHE-199I Section XI Warranty What will we do to correct problems? How do you get warranty assistance?What should you do to keep the warranty in effect? What will we not do?Page Page Fax/215-641-1670 Parts Fax/215-641-2180