Bradford-White Corp TGHE-160I-N(X), TGHE-1991-N(X) instruction manual Flame Rod

Page 54

 

Table 18. (IG) Ignition System.

 

 

Wire Color

Voltage

Resistance

Connector

Pin

No.

Nos.

 

 

 

Grey-Grey

90-110 VAC

n/a

D1

1-2

 

Table 19. (FM) Combustion Fan Motor.

 

 

Wire Color

Voltage

Resistance

Connector

Pin

No.

Nos.

 

 

 

Red-Black

6-45 VDC

n/a

L1

1-2

White-Black

5-10 VDC

9.2-9.4k ohms

L1

2-4

Yellow-Black

11-13 VDC

3.5-3.9k ohms

L1

2-3

Set your meter to the hertz scale. Reading across the white and black wires at terminals 2 and 4 you should read between 60 and 420 hertz.

 

Table 20. Thermal Fuse / Overheat Switch.

 

 

Wire Color

Voltage

Resistance

 

Connector

Pin

 

No.

Nos.

 

 

 

 

Red-White

11-13 VDC

Below 1 ohms

 

B1

B13-

 

E1

E9

 

 

 

 

 

 

 

 

 

 

Flame Rod:

Place one lead of your meter to the flame rod and the other to ground. With the unit running, you should read between 5-150 VAC. Set your meter to micro-amp scale and series your meter in line with the flame rod. You should read 1 micro-amp or greater for proper flame circuit. In the event of low flame circuit, remove the flame rod and check for carbon or damage.

Heat Exchanger and Outgoing Water Temperature Thermistors:

Check all Thermistors by inserting meter leads into each end of the thermistor plug. Set your meter to the 20k scale and read resistance. Applying heat to the thermistor bulb should decrease the resistance. Applying ice to the thermistor bulb should increase the resistance. See below for examples of typical temperatures and resistance readings.

Example:

 

59ºF = 11.4-14kΩ

140ºF = 2.2-2.7kΩ

 

 

 

86ºF = 6.4-7.8kΩ

221ºF = 0.6-0.8kΩ

 

 

 

113º = 3.6-4.5kΩ

 

 

 

 

 

Table 21. Outgoing Water Thermistor.

 

 

Wire Color

 

Voltage

 

Resistance

Connector

Pin

 

 

No.

Nos.

 

 

 

 

 

White-White

 

n/a

 

See example

E4

E3-E4

 

 

above

 

 

 

 

 

 

Blue-Blue

 

n/a

 

See example

E3

E6-E5

 

 

above

 

 

 

 

 

 

 

Table 22. Heat Exchanger Temperature Thermistor.

 

Wire Color

 

Voltage

 

Resistance

Connector

Pin

 

 

No.

Nos.

 

 

 

 

 

Pink-Pink

 

n/a

 

See example

E2

5-10

 

 

above

 

 

 

 

 

 

 

 

Table 23. Surge Protector.

 

 

Wire Color

 

Voltage

 

Resistance

Connector

Pin

 

 

No.

Nos.

 

 

 

 

 

Black-White

 

108-132 VAC

 

n/a

C2

1-3

White-White

 

108-132 VAC

 

n/a

C1

1-3

54

Image 54
Contents TGHE-160I-NX & TGHE-199I-NX Table of Contents Page Page If YOU Smell GAS Section II Specifications ModelDimensions Pressure Drop psi Water Flow Rate gpm Section III Installation Instructions Unpacking Water Heater LocationRemove Carton Mount Water Heater on the Wall State Regulations Important In the State of Massachusetts 248CMR 4.00Section IV Water Connections Water QualityInstructions for Connections Page Approximate TIME/TEMPERATURE Relationships in Scalds Recommended Piping for a Basic Installation Recommended Piping for a Circulation Systems Recommended Piping for Power Failure Freeze Protection Recommended Piping for Freeze ProtectionPressure Relief Valve Page Page Section V Venting Venting Vent / Air Intake Terminal Locations Direct Vent Terminal LocationVenting System Installation Venting System LayoutPrior to the Installation of the EverHot Direct Vent System Horizontal Direct Vent InstallationsIllustration Showing a Horizontal Termination Installation Vertical Direct Vent Installations Vertical Vent InstallationsCombustion Blower Dip Switch Settings Dip SwitchInstallation of Venting System Components Condensate Recommended Vent/Air Intake Terminal PositionJoint Connection Coping with CondensationIllustration Showing How to Shorten Vent Extensions Shortening of Vent ExtensionsVenting Parts & Dimensions Components Needed for Direct Vent ApplicationsVent Pipe Clamp, p/n Page Measure Dimension to Fit Illustration Showing How to Properly Cut a Vent ExtensionFinal Installation of the Vent System Illustration Showing How to Cut the Vertical Vent to Fit Cut the Vent to FitHigh Altitude Installations Mounting the Vent System Vertical DischargePage Venting Suppliers Manufacturer ProductSection VI GAS Connections Gas GAS Meter Size Natural GAS onlyGAS Pressure Regulation Specific CorrectionInitial Operation and Testing Installer only Section VII Electrical Connections Ladder Diagram Wiring Diagram for Tghe Models Temperature Controls Page Securing screw Wiring hole 21/32 Installation of Remote Controls OptionalIllustration Showing Where to Connect Remote Control Harness Resistance Connector Pin Nos Initial Operation and Testing of Controls Installer onlyTroubleshooting Electrical Wire ColorHeat Exchanger and Outgoing Water Temperature Thermistors Flame RodFrost Protection Amp FusesSection Viii Operating Instructions General Instructions To Fill the Water HeaterSequence of Operation What to do if YOU Smell GAS Lighting Instructions For Your Safety Read Before OperatingProperty damage, personal injury or loss of life Operation InstructionsTemperature Adjustment Turning OFF the Water Heater for AN Extended Period of TimePage Approximate TIME/TEMPERATURE Relationships in Scalds ScaldingFirst AID for Scalds Code Code DescriptionCode Code Description Thermal Fuse Code Code Description Nothing happens Section IX Maintenance Burner Flame AppearancePage Circulating Pump Water HeaterPage Section X Parts List TGHE-160I TGHE-199I Description QuantityPage TGHE-160I TGHE-199I Page TGHE-160I TGHE-199I Page TGHE-160I TGHE-199I Section XI Warranty What should you do to keep the warranty in effect? What will we do to correct problems?How do you get warranty assistance? What will we not do?Page Page Fax/215-641-1670 Parts Fax/215-641-2180